{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,28]],"date-time":"2025-11-28T12:30:39Z","timestamp":1764333039974,"version":"3.41.0"},"reference-count":33,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"18","license":[{"start":{"date-parts":[[2021,5,7]],"date-time":"2021-05-07T00:00:00Z","timestamp":1620345600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>Abstract<\/jats:title>\n            <jats:p>The aim of this study was to develop a new breast density classification system for dedicated breast computed tomography (BCT) based on lesion detectability analogous to the ACR BI-RADS breast density scale for mammography, and to evaluate its interrater reliability.<\/jats:p>\n            <jats:p>In this retrospective study, 1454 BCT examinations without contrast media were screened for suitability. Excluding datasets without additional ultrasound and exams without any detected lesions resulted in 114 BCT examinations. Based on lesion detectability, an atlas-based BCT density (BCTD) classification system of breast parenchyma was defined using 4 categories. Interrater reliability was examined in 40 BCT datasets between 3 experienced radiologists.<\/jats:p>\n            <jats:p>Among the included lesions were 63 cysts (55%), 18 fibroadenomas (16%), 7 lesions of fatty necrosis (6%), and 6 breast cancers (5%) with a median diameter of 11\u200amm. X-ray absorption was identical between lesions and breast tissue; therefore, the lack of fatty septae was identified as the most important criteria for the presence of lesions in glandular tissue. Applying a lesion diameter of 10\u200amm as desired cut-off for the recommendation of an additional ultrasound, an atlas of 4 BCTD categories was defined resulting in a distribution of 17.5% for density A, 39.5% (B), 31.6% (C), and 11.4% (D) with an intraclass correlation coefficient (ICC) among 3 readers of 0.85 to 0.87.<\/jats:p>\n            <jats:p>We propose a dedicated atlas-based BCTD classification system, which is calibrated to lesion detectability. The new classification system exhibits a high interrater reliability and may be used for the decision whether additional ultrasound is recommended.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000025844","type":"journal-article","created":{"date-parts":[[2021,5,6]],"date-time":"2021-05-06T08:21:38Z","timestamp":1620289298000},"page":"e25844","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":10,"title":["Breast density in dedicated breast computed tomography"],"prefix":"10.1097","volume":"100","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0452-7163","authenticated-orcid":false,"given":"Jann","family":"Wieler","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7936-5808","authenticated-orcid":false,"given":"Nicole","family":"Berger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Frauenfelder","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Magda","family":"Marcon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1091-5434","authenticated-orcid":false,"given":"Andreas","family":"Boss","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2021,5,7]]},"reference":[{"key":"R1-20250613","first-page":"59","article-title":"Current strategies for the prevention of breast cancer","volume":"6","author":"Advani","year":"2014","journal-title":"Breast Cancer (Dove Med Press)"},{"key":"R2-20250613","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1001\/jama.2017.19130","article-title":"Association of screening and treatment with breast cancer mortality by molecular subtype in US women, 2000-2012","volume":"319","author":"Plevritis","year":"2018","journal-title":"JAMA"},{"key":"R3-20250613","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1056\/NEJMoa062790","article-title":"Mammographic density and the risk and detection of breast cancer","volume":"356","author":"Boyd","year":"2007","journal-title":"N Engl J Med"},{"key":"R4-20250613","doi-asserted-by":"crossref","first-page":"2137","DOI":"10.1200\/JCO.2005.05.2308","article-title":"Patterns of cancer incidence, mortality, and prevalence across five continents: defining priorities to reduce cancer disparities in different geographic regions of the world","volume":"24","author":"Kamangar","year":"2006","journal-title":"J Clin Oncol"},{"key":"R5-20250613","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1002\/1097-0142(20000715)89:2<369::AID-CNCR23>3.0.CO;2-J","article-title":"The association of increased weight, body mass index, and tissue density with the risk of breast carcinoma in Vermont","volume":"89","author":"Lam","year":"2000","journal-title":"Cancer"},{"key":"R6-20250613","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/j.jmir.2015.10.008","article-title":"Mammographic breast density:comparison across women with conclusive and inconclusive mammography reports","volume":"47","author":"Ekpo","year":"2016","journal-title":"J Med Imaging Radiat Sci"},{"key":"R7-20250613","doi-asserted-by":"crossref","first-page":"1261","DOI":"10.2214\/ajr.167.5.8911192","article-title":"Analysis of parenchymal density on mammograms in 1353 women 25-79\u200ayears old","volume":"167","author":"Stomper","year":"1996","journal-title":"AJR Am J Roentgenol"},{"key":"R8-20250613","doi-asserted-by":"crossref","first-page":"2151","DOI":"10.1001\/jama.299.18.2151","article-title":"Combined screening with ultrasound and mammography vs mammography alone in women at elevated risk of breast cancer","volume":"299","author":"Berg","year":"2008","journal-title":"JAMA"},{"key":"R9-20250613","doi-asserted-by":"crossref","DOI":"10.14694\/EdBook_AM.2013.33.e57","article-title":"Mammographic density and risk of breast cancer","author":"Boyd","year":"2013","journal-title":"Am Soc Clin Oncol Educ Book"},{"key":"R10-20250613","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1148\/radiol.2251011667","article-title":"Comparison of the performance of screening mammography, physical examination, and breast US and evaluation of factors that influence them: an analysis of 27,825 patient evaluations","volume":"225","author":"Kolb","year":"2002","journal-title":"Radiology"},{"key":"R11-20250613","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1016\/j.amjsurg.2019.01.039","article-title":"Redefining the sensitivity of screening mammography: A review","volume":"218","author":"Hollingsworth","year":"2019","journal-title":"Am J Surg"},{"key":"R12-20250613","doi-asserted-by":"crossref","first-page":"1394","DOI":"10.1001\/jama.2012.388","article-title":"Detection of breast cancer with addition of annual screening ultrasound or a single screening MRI to mammography in women with elevated breast cancer risk","volume":"307","author":"Berg","year":"2012","journal-title":"JAMA"},{"key":"R13-20250613","doi-asserted-by":"crossref","first-page":"927","DOI":"10.1055\/a-0646-4522","article-title":"Interdisciplinary screening, diagnosis, therapy and follow-up of breast cancer. Guideline of the DGGG and the DKG (S3-Level, AWMF Registry Number 032\/045OL, December 2017) - part 1 with recommendations for the screening, diagnosis and therapy of breast cancer","volume":"78","author":"Wockel","year":"2018","journal-title":"Geburtshilfe Frauenheilkd"},{"key":"R14-20250613","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1097\/RLI.0000000000000552","article-title":"Dedicated breast computed tomography with a photon-counting detector initial results of clinical in vivo imaging","volume":"54","author":"Berger","year":"2019","journal-title":"Invest Radiol"},{"key":"R15-20250613","doi-asserted-by":"crossref","first-page":"108674","DOI":"10.1016\/j.ejrad.2019.108674","article-title":"Comparison of comfort between cone beam breast computed tomography and digital mammography","volume":"120","author":"Li","year":"2019","journal-title":"Eur J Radiol"},{"key":"R16-20250613","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1097\/RLI.0000000000000609","article-title":"Dedicated spiral breast computed tomography with a single photon-counting detector: initial results of the first 300 women","volume":"55","author":"Berger","year":"2020","journal-title":"Invest Radiol"},{"key":"R17-20250613","doi-asserted-by":"crossref","DOI":"10.1097\/RLI.0000000000000662","article-title":"Lesion detectability and radiation dose in spiral breast CT with photon-counting detector technology: a phantom study","author":"Shim","year":"2020","journal-title":"Invest Radiol"},{"key":"R18-20250613","doi-asserted-by":"crossref","first-page":"496","DOI":"10.2214\/AJR.08.1017","article-title":"Cone-beam CT for breast imaging: radiation dose, breast coverage, and image quality","volume":"195","author":"O\u2019Connell","year":"2010","journal-title":"AJR Am J Roentgenol"},{"key":"R19-20250613","doi-asserted-by":"crossref","first-page":"5185","DOI":"10.1007\/s00330-017-4911-z","article-title":"The role of cone-beam breast-CT for breast cancer detection relative to breast density","volume":"27","author":"Wienbeck","year":"2017","journal-title":"Eur Radiol"},{"key":"R20-20250613","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1016\/j.ejrad.2015.11.029","article-title":"The utility of breast cone-beam computed tomography, ultrasound, and digital mammography for detecting malignant breast tumors: a prospective study with 212 patients","volume":"85","author":"He","year":"2016","journal-title":"Eur J Radiol"},{"key":"R21-20250613","doi-asserted-by":"crossref","first-page":"09","DOI":"10.1016\/j.ejrad.2017.12.003","article-title":"Contrast-enhanced cone-beam breast-CT: analysis of optimal acquisition time for discrimination of breast lesion malignancy","volume":"99","author":"Uhlig","year":"2018","journal-title":"Eur J Radiol"},{"key":"R22-20250613","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1016\/j.tranon.2017.05.004","article-title":"Cone-beam breast computed tomography: CT density does not reflect proliferation potential and receptor expression of breast carcinoma","volume":"10","author":"Wienbeck","year":"2017","journal-title":"Transl Oncol"},{"key":"R23-20250613","doi-asserted-by":"crossref","first-page":"3731","DOI":"10.1007\/s00330-018-5376-4","article-title":"Contrast-enhanced cone-beam breast-CT (CBBCT): clinical performance compared to mammography and MRI","volume":"28","author":"Wienbeck","year":"2018","journal-title":"Eur Radiol"},{"key":"R24-20250613","doi-asserted-by":"crossref","first-page":"752","DOI":"10.1016\/j.acra.2018.07.023","article-title":"A reliability comparison of cone-beam breast computed tomography and mammography: breast density assessment referring to the fifth edition of the BI-RADS atlas","volume":"26","author":"Ma","year":"2019","journal-title":"Acad Radiol"},{"key":"R25-20250613","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1148\/radiol.2282011860","article-title":"Measurement of observer agreement","volume":"228","author":"Kundel","year":"2003","journal-title":"Radiology"},{"key":"R26-20250613","doi-asserted-by":"crossref","first-page":"159","DOI":"10.2307\/2529310","article-title":"The measurement of observer agreement for categorical data","volume":"33","author":"Landis","year":"1977","journal-title":"Biometrics"},{"key":"R27-20250613","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1136\/bmj.305.6851.443","article-title":"Discomfort and pain during mammography: description, prediction, and prevention","volume":"305","author":"Rutter","year":"1992","journal-title":"BMJ"},{"key":"R28-20250613","first-page":"180","article-title":"Once is enough--why some women do not continue to participate in a breast cancer screening programme","volume":"111","author":"Elwood","year":"1998","journal-title":"N Z Med J"},{"key":"R29-20250613","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1016\/j.breast.2013.03.003","article-title":"The effect of mammography pain on repeat participation in breast cancer screening: a systematic review","volume":"22","author":"Whelehan","year":"2013","journal-title":"Breast"},{"key":"R30-20250613","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.1007\/s00330-016-4459-3","article-title":"Technical feasibility proof for high-resolution low-dose photon-counting CT of the breast","volume":"27","author":"Kalender","year":"2017","journal-title":"Eur Radiol"},{"key":"R31-20250613","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.2214\/AJR.15.15049","article-title":"Assessment of interradiologist agreement regarding mammographic breast density classification using the fifth edition of the BI-RADS atlas","volume":"206","author":"Ekpo","year":"2016","journal-title":"AJR Am J Roentgenol"},{"key":"R32-20250613","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1186\/s12885-015-1256-3","article-title":"Inter-observer agreement according to three methods of evaluating mammographic density and parenchymal pattern in a case control study: impact on relative risk of breast cancer","volume":"15","author":"Winkel","year":"2015","journal-title":"BMC Cancer"},{"key":"R33-20250613","doi-asserted-by":"crossref","first-page":"20180691","DOI":"10.1259\/bjr.20180691","article-title":"Determination of mammographic breast density using a deep convolutional neural network","volume":"92","author":"Ciritsis","year":"2019","journal-title":"Br J Radiol"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000025844","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,13]],"date-time":"2025-06-13T15:02:44Z","timestamp":1749826964000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000025844"}},"subtitle":["Proposal of a classification system and interreader reliability"],"short-title":[],"issued":{"date-parts":[[2021,5,7]]},"references-count":33,"journal-issue":{"issue":"18","published-online":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000025844","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"type":"print","value":"0025-7974"},{"type":"electronic","value":"1536-5964"}],"subject":[],"published":{"date-parts":[[2021,5,7]]},"assertion":[{"value":"2020-07-28","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-04-17","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}