{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T10:31:07Z","timestamp":1780482667075,"version":"3.54.1"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"24","license":[{"start":{"date-parts":[[2021,6,18]],"date-time":"2021-06-18T00:00:00Z","timestamp":1623974400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"funder":[{"DOI":"10.13039\/501100003725","name":"National Research Foundation of Korea","doi-asserted-by":"crossref","award":["NRF-2018R1A2B2003556"],"award-info":[{"award-number":["NRF-2018R1A2B2003556"]}],"id":[{"id":"10.13039\/501100003725","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>Abstract<\/jats:title>\n            <jats:p>Although infra-acetabular screws have been used for anterior and posterior column transfixation, a screw penetrating the hip joint can result in harmful complications. However, the most accurate intraoperative radiologic imaging tool for identifying articular penetration has not been established. The purpose of the present study was, therefore, to evaluate the consistency with which standard pelvic radiographs compared with computed tomography (CT) can be used for demonstrating articular penetration.<\/jats:p>\n            <jats:p>This retrospective review was performed between January 2015 and December 2020. We evaluated the records of patients with acetabular or pelvic fractures who underwent open reduction and internal fixation with infra-acetabular screw placement. We collected demographic data and described infra-acetabular screw placement as follows: ideal placement, articular penetration, and out of the bone. Articular penetration was assessed independently on each pelvic radiograph and compared statistically with the CT scans. Sensitivity, specificity, correct interpretation rate, and prevalence-adjusted bias-adjusted kappa (PABAK) were calculated for each radiograph.<\/jats:p>\n            <jats:p>Thirty-nine patients underwent infra-acetabular screw placement. The mean age of patients was 55\u200ayears (range, 27\u201390\u200ayears); there were 29 men and 10 women. One patient underwent bilateral infra-acetabular screw placement; therefore, 40 infra-acetabular screws were included in total. Six (6\/40, 15%) infra-acetabular screws showed articular penetration on CT and two (2\/40, 5%) showed infra-acetabular screws extending out of the bone. Hip joint penetration was correctly identified at a rate of 92.5% (95% confidence interval [CI], 79.6\u201398.4%) on the outlet view and 87.5% (95% CI, 73.2\u201395.8%) on the anteroposterior (AP) view. The PABAK for the agreement between pelvic radiographs and CT scans was 0.85 in the outlet view and 0.75 in the AP view.<\/jats:p>\n            <jats:p>The outlet view is an accurate method for detecting articular penetration of infra-acetabular screws. We recommend the insertion of an infra-acetabular screw under fluoroscopic outlet view to avoid articular penetration intraoperatively.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000026392","type":"journal-article","created":{"date-parts":[[2021,6,17]],"date-time":"2021-06-17T14:02:44Z","timestamp":1623938564000},"page":"e26392","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Which radiograph is most accurate for assessing hip joint penetration in infra-acetabular screw placement?"],"prefix":"10.1097","volume":"100","author":[{"given":"Eic Ju","family":"Lim","sequence":"first","affiliation":[{"name":"Department of Orthopedic Surgery, Chungbuk National University Hospital, Chungbuk National University, Cheongju"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seungyeob","family":"Sakong","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Korea University Guro Hospital, Korea University Medical Center, Seoul, Republic of Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wonseok","family":"Choi","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Korea University Guro Hospital, Korea University Medical Center, Seoul, Republic of Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jong-Keon","family":"Oh","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Korea University Guro Hospital, Korea University Medical Center, Seoul, Republic of Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4962-3535","authenticated-orcid":false,"given":"Jae-Woo","family":"Cho","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Korea University Guro Hospital, Korea University Medical Center, Seoul, Republic of Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,6,18]]},"reference":[{"key":"R1-20250504","first-page":"27","article-title":"Conservative treatment of fractures of the acetabulum. Results after longtime follow-up","volume":"88","author":"Hesp","year":"1988","journal-title":"Acta Chir Belg"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"297","DOI":"10.3109\/17453679209154786","article-title":"Epidemiology of pelvic fractures in a Swedish county","volume":"63","author":"Ragnarsson","year":"1992","journal-title":"Acta Orthop Scand"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/0020-1383(95)92181-9","article-title":"Unstable pelvic fractures: a retrospective analysis","volume":"26","author":"van Veen","year":"1995","journal-title":"Injury"},{"key":"R4-20250504","first-page":"244","article-title":"Infra-acetabular corridor--technical tip for an additional screw placement to increase the fixation strength of acetabular fractures","volume":"70","author":"Culemann","year":"2011","journal-title":"J Trauma"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"1664","DOI":"10.1097\/TA.0b013e3182463b45","article-title":"Screw- versus plate-fixation strength of acetabular anterior column fractures: a biomechanical study","volume":"72","author":"Gras","year":"2012","journal-title":"J Trauma Acute Care Surg"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1016\/j.injury.2011.11.009","article-title":"Biomechanical comparison of different acetabular plate systems and constructs--the role of an infra-acetabular screw placement and use of locking plates","volume":"43","author":"Marintschev","year":"2012","journal-title":"Injury"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"1047","DOI":"10.2106\/JBJS.17.00295","article-title":"Comparison of fixation techniques for acetabular fractures involving the anterior column with disruption of the quadrilateral plate: a biomechanical study","volume":"100","author":"May","year":"2018","journal-title":"J Bone Joint Surg Am"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1097\/BOT.0b013e3181bfcebf","article-title":"The 'safe zone\u2019 for extra-articular screw placement during intra-pelvic acetabular surgery","volume":"24","author":"Guy","year":"2010","journal-title":"J Orthop Trauma"},{"key":"R9-20250504","first-page":"223","article-title":"Anatomy of the obturator region: relations to a trans-obturator sling","volume":"15","author":"Whiteside","year":"2004","journal-title":"Int Urogynecol J Pelvic Floor Dysfunct"},{"key":"R11-20250504","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1007\/s11999-014-3932-z","article-title":"Sex-specific differences of the infraacetabular corridor: a biomorphometric CT-based analysis on a database of 523 pelves","volume":"473","author":"Gras","year":"2015","journal-title":"Clin Orthop Relat Res"},{"issue":"(Suppl 2)","key":"R12-20250504","doi-asserted-by":"crossref","first-page":"S37","DOI":"10.1097\/BOT.0000000000001403","article-title":"Improved intraoperative fluoroscopy for pelvic and acetabular surgery","volume":"33","author":"Routt","year":"2019","journal-title":"J Orthop Trauma"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1016\/0895-4356(93)90018-V","article-title":"Bias, prevalence and kappa","volume":"46","author":"Byrt","year":"1993","journal-title":"J Clin Epidemiol"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1097\/00005131-198909000-00003","article-title":"Radiological diagnosis of screw penetration of the hip joint in acetabular fracture reconstruction","volume":"3","author":"Ebraheim","year":"1989","journal-title":"J Orthop Trauma"},{"key":"R15-20250504","doi-asserted-by":"crossref","first-page":"5953","DOI":"10.12659\/MSM.915906","article-title":"Acetabular lateral view: effective fluoroscopic imaging to evaluate screw penetration intraoperatively","volume":"25","author":"Lin","year":"2019","journal-title":"Med Sci Monit"},{"key":"R16-20250504","doi-asserted-by":"crossref","first-page":"e133","DOI":"10.1097\/BOT.0000000000000724","article-title":"Use of inlet-obturator oblique view (leeds view) for placement of posterior wall screws in acetabular fracture surgery","volume":"31","author":"Tosounidis","year":"2017","journal-title":"J Orthop Trauma"},{"key":"R17-20250504","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1186\/s13018-018-0833-y","article-title":"Secure corridor for infraacetabular screws in acetabular fracture fixation-a 3-D radiomorphometric analysis of 124 pelvic CT datasets","volume":"13","author":"Arlt","year":"2018","journal-title":"J Orthop Surg Res"},{"key":"R18-20250504","doi-asserted-by":"crossref","first-page":"464","DOI":"10.4055\/jkoa.2004.39.5.464","article-title":"Anatomic assessment of the acetabular fossa for screw fixation in acetabular fracture","volume":"39","author":"Won","year":"2004","journal-title":"J Korean Orthop Assoc"},{"key":"R19-20250504","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1097\/00005131-199908000-00004","article-title":"Intraoperative fluoroscopy to evaluate fracture reduction and hardware placement during acetabular surgery","volume":"13","author":"Norris","year":"1999","journal-title":"J Orthop Trauma"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000026392","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T05:40:54Z","timestamp":1746337254000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000026392"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6,18]]},"references-count":18,"journal-issue":{"issue":"24","published-online":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000026392","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,6,18]]},"assertion":[{"value":"2020-11-08","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-05-26","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}