{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,5]],"date-time":"2025-05-05T04:02:25Z","timestamp":1746417745393,"version":"3.40.4"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"28","license":[{"start":{"date-parts":[[2021,7,16]],"date-time":"2021-07-16T00:00:00Z","timestamp":1626393600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Introduction:<\/jats:title>\n            <jats:p>Thoracentesis is performed to both diagnose and\/or treat pleural effusion, and several important complications of thoracentesis are occasionally observed. To assess precise thoracentesis procedures, we evaluated the position of the needle tip during thoracentesis by using a thoracentesis unit, comparing experienced and inexperienced groups.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Twenty eight physicians (19 board-certified pulmonologists as an experienced group and the remaining 9 as an inexperienced group) participated at Fukujuji Hospital in January 2021. All participants performed 2 punctures with a handmade thoracentesis unit and measured the needle\u2018s angle to the midline.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The median distance from the needle tip to the midline when the needle was inserted 5\u200acm (D5) was 0.47\u200acm (range 0.06\u20131.05), and the median difference between D5 on the 1st puncture (D5<jats:sub>1st<\/jats:sub>) and D5 on the 2nd puncture (D5<jats:sub>2nd<\/jats:sub>) was 0.22\u200acm (range 0.00\u20130.69). D5 was shorter in the experienced group than in the inexperienced group (median 0.40\u200acm (range 0.06\u20130.66) vs 0.58\u200acm (range 0.44\u20131.05), <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&lt;\u200a.001). There were no significant differences in the D5<jats:sub>1st<\/jats:sub> and D5<jats:sub>2nd<\/jats:sub> distances between the experienced and inexperienced groups (median 0.22\u200acm (range 0.00\u20130.40) vs 0.41\u200acm (range 0.04\u20130.69), <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a=\u200a.094). When 4 areas were divided by the x-axis and y-axis, 32 punctures (55.2%) deviated to the right-upper quadrant, and 25 (86.2%) of participants made the 1st puncture and 2nd puncture in the same direction.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>All doctors should know that the needle direction might shift by approximately 1\u200acm, and more than half of the practitioners punctured towards the upper right.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000026600","type":"journal-article","created":{"date-parts":[[2021,7,14]],"date-time":"2021-07-14T21:07:26Z","timestamp":1626296846000},"page":"e26600","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Evaluation of the position of the needle tip during thoracentesis"],"prefix":"10.1097","volume":"100","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2465-0118","authenticated-orcid":false,"given":"Masafumi","family":"Shimoda","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kozo","family":"Morimoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshiaki","family":"Tanaka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kozo","family":"Yoshimori","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ken","family":"Ohta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2021,7,16]]},"reference":[{"key":"R1-20250504","doi-asserted-by":"crossref","first-page":"01","DOI":"10.1007\/s13665-018-0194-3","article-title":"Management of septated malignant pleural effusions","volume":"7","author":"Banka","year":"2018","journal-title":"Curr Pulmonol Rep"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"799","DOI":"10.7326\/0003-4819-103-5-799","article-title":"Diagnostic thoracentesis and pleural biopsy in pleural effusions. Health and Public Policy Committee, American College of Physicians","volume":"103","year":"1985","journal-title":"Ann Intern Med"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"873","DOI":"10.1001\/archinte.1990.00390160119023","article-title":"Complications associated with thoracentesis. A prospective, randomized study comparing three different methods","volume":"150","author":"Grogan","year":"1990","journal-title":"Arch Intern Med"},{"key":"R4-20250504","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1136\/thoraxjnl-2014-206114","article-title":"Thoracentesis outcomes: a 12-year experience","volume":"70","author":"Ault","year":"2015","journal-title":"Thorax"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1001\/archinternmed.2009.548","article-title":"Pneumothorax following thoracentesis: a systematic review and meta-analysis","volume":"170","author":"Gordon","year":"2010","journal-title":"Arch Intern Med"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"1315","DOI":"10.1378\/chest.08-1227","article-title":"Reducing iatrogenic risk in thoracentesis: establishing best practice via experiential training in a zero-risk environment","volume":"135","author":"Duncan","year":"2009","journal-title":"Chest"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1186\/s13089-020-00172-9","article-title":"Real-time ultrasound-guided thoracentesis in the intensive care unit: prevalence of mechanical complications","volume":"12","author":"Rodriguez Lima","year":"2020","journal-title":"Ultrasound J"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"917","DOI":"10.2214\/ajr.156.5.2017951","article-title":"Factors affecting the development of pneumothorax associated with thoracentesis","volume":"156","author":"Raptopoulos","year":"1991","journal-title":"AJR Am J Roentgenol"},{"key":"R9-20250504","doi-asserted-by":"crossref","first-page":"266","DOI":"10.12788\/jhm.2716","article-title":"Safe and effective bedside thoracentesis: a review of the evidence for practicing clinicians","volume":"12","author":"Schildhouse","year":"2017","journal-title":"J Hosp Med"},{"key":"R10-20250504","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1002\/jcu.20163","article-title":"Sonographically guided thoracentesis and rate of pneumothorax","volume":"33","author":"Barnes","year":"2005","journal-title":"J Clin Ultrasound"},{"key":"R11-20250504","doi-asserted-by":"crossref","first-page":"e129","DOI":"10.1016\/j.jtcvs.2017.01.030","article-title":"The American Association for Thoracic Surgery consensus guidelines for the management of empyema","volume":"153","author":"Shen","year":"2017","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R12-20250504","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1038\/bmt.2012.244","article-title":"Investigation of the freely available easy-to-use software \u2019EZR\u2019 for medical statistics","volume":"48","author":"Kanda","year":"2013","journal-title":"Bone Marrow Transplant"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1016\/j.injury.2015.11.045","article-title":"Chest wall thickness and decompression failure: a systematic review and meta-analysis comparing anatomic locations in needle thoracostomy","volume":"47","author":"Laan","year":"2016","journal-title":"Injury"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"955","DOI":"10.1007\/s001340050988","article-title":"Feasibility and safety of ultrasound-aided thoracentesis in mechanically ventilated patients","volume":"25","author":"Lichtenstein","year":"1999","journal-title":"Intensive Care Med"},{"key":"R15-20250504","doi-asserted-by":"crossref","first-page":"942","DOI":"10.21037\/jtd.2019.12.39","article-title":"Incidence and risk factors of pneumothorax following pre-procedural ultrasound-guided thoracentesis","volume":"12","author":"Shechtman","year":"2020","journal-title":"J Thorac Dis"},{"key":"R16-20250504","first-page":"340","article-title":"End of the \u201csee one, do one, teach one\u201d era: the next generation of invasive bedside procedural instruction","volume":"110","author":"Lenchus","year":"2010","journal-title":"J Am Osteopath Assoc"},{"key":"R17-20250504","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1002\/jhm.268","article-title":"Mastery learning of thoracentesis skills by internal medicine residents using simulation technology and deliberate practice","volume":"3","author":"Wayne","year":"2008","journal-title":"J Hosp Med"},{"key":"R18-20250504","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/j.amjmed.2005.08.007","article-title":"Beyond the comfort zone: residents assess their comfort performing inpatient medical procedures","volume":"119","author":"Huang","year":"2006","journal-title":"Am J Med"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000026600","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T05:37:41Z","timestamp":1746337061000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000026600"}},"subtitle":["Experimental study"],"short-title":[],"issued":{"date-parts":[[2021,7,16]]},"references-count":18,"journal-issue":{"issue":"28","published-online":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000026600","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"type":"print","value":"0025-7974"},{"type":"electronic","value":"1536-5964"}],"subject":[],"published":{"date-parts":[[2021,7,16]]},"assertion":[{"value":"2021-03-09","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-06-22","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}