{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T07:10:03Z","timestamp":1746342603047,"version":"3.40.4"},"reference-count":10,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"37","license":[{"start":{"date-parts":[[2021,9,17]],"date-time":"2021-09-17T00:00:00Z","timestamp":1631836800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100010486","name":"Teijin Pharma","doi-asserted-by":"crossref","award":["no"],"award-info":[{"award-number":["no"]}],"id":[{"id":"10.13039\/501100010486","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Introduction<\/jats:title>\n            <jats:p>: When using portable oxygen, a demand oxygen delivery system (DODS), which senses the beginning of inhalation and delivers a bolus of oxygen, is often used. However, conventional DODS may not supply sufficient oxygen when reduced tidal flow fails to trigger the flow sensor. Recently, \u201cauto-DODS,\u201d which detects the negative pressure of inhalation and switches among 3 trigger sensitivity levels (<jats:italic toggle=\"yes\">standard<\/jats:italic>, <jats:italic toggle=\"yes\">high,<\/jats:italic> and <jats:italic toggle=\"yes\">extra high<\/jats:italic>), has been developed to improve the efficacy of oxygenation. An auto-DODS can also supply pulsed-flow oxygen when it detects apnea, whereas a conventional DODS has only <jats:italic toggle=\"yes\">standard<\/jats:italic> sensitivity. This randomized, open-label, crossover pilot study compared the performance of an auto-DODS with that of a conventional DODS.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>: We recruited patients with chronic obstructive pulmonary disease (COPD) or interstitial pneumonia receiving long-term oxygen therapy. Interventions were performed on 2 different days for each participant. On each day, an auto-DODS or a conventional DODS were tested at rest for 30 minutes and during the 6-minute walk test. The primary outcome was mean oxygen saturation (SpO2). Secondary outcomes were the ratios of time for each sensitivity level and pulsed-flow oxygen when using the auto-DODS, total time desaturated below SpO2 90%, percentage of time desaturated below SpO2 90%, minimum SpO2, mean and maximum pulse rate, six-minute walk distance, recovery time after 6-minute walk test, modified Borg scale, comfort, and discomfort index.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>: When using the auto-DODS at rest, a <jats:italic toggle=\"yes\">high<\/jats:italic> or <jats:italic toggle=\"yes\">extra high<\/jats:italic> sensitivity level was observed in addition to <jats:italic toggle=\"yes\">standard<\/jats:italic> sensitivity in 6 of 8 participants. During the 6-minute walk test, only <jats:italic toggle=\"yes\">standard<\/jats:italic> sensitivity was observed in 6 participants. Mean SpO2 differences between the auto-DODS and conventional DODS at rest and during the 6-minute walk test were \u22120.6 [\u22124.5, 3.4] and 0.0 [\u22122.5, 2.5] ([95% confidence interval]), respectively, neither of which were significant (<jats:italic toggle=\"yes\">P<\/jats:italic>\u200a=\u200a.73 and <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a=\u200a.99). There were no significant differences in secondary outcomes. There were no adverse events when using the auto-DODS.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>: This study showed that the auto-DODS did not show superiority in oxygenation either at rest or during exercise compared to a conventional DODS. The auto-DODS was shown to supply oxygen safely and detect inhalations with various trigger sensitivities.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000027191","type":"journal-article","created":{"date-parts":[[2021,9,17]],"date-time":"2021-09-17T13:02:10Z","timestamp":1631883730000},"page":"e27191","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["A randomized crossover pilot study comparing the efficacy of an auto-demand oxygen delivery system with that of a conventional demand oxygen delivery system in patients with chronic respiratory failure"],"prefix":"10.1097","volume":"100","author":[{"given":"Takehiro","family":"Otoshi","sequence":"first","affiliation":[{"name":"Division of Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-1 Kusunokicho, Chuo-ku, Kobe, Hyogo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0790-5139","authenticated-orcid":false,"given":"Tatsuya","family":"Nagano","sequence":"additional","affiliation":[{"name":"Division of Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-1 Kusunokicho, Chuo-ku, Kobe, Hyogo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sae","family":"Murakami","sequence":"additional","affiliation":[{"name":"Clinical and Translational Research Center, Kobe University Hospital, 7-5-2 Kusunokicho, Chuo-ku, Kobe, Hyogo, Japan."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takashi","family":"Omori","sequence":"additional","affiliation":[{"name":"Clinical and Translational Research Center, Kobe University Hospital, 7-5-2 Kusunokicho, Chuo-ku, Kobe, Hyogo, Japan."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daisuke","family":"Hazama","sequence":"additional","affiliation":[{"name":"Division of Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-1 Kusunokicho, Chuo-ku, Kobe, Hyogo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naoko","family":"Katsurada","sequence":"additional","affiliation":[{"name":"Division of Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-1 Kusunokicho, Chuo-ku, Kobe, Hyogo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masatsugu","family":"Yamamoto","sequence":"additional","affiliation":[{"name":"Division of Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-1 Kusunokicho, Chuo-ku, Kobe, Hyogo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Motoko","family":"Tachihara","sequence":"additional","affiliation":[{"name":"Division of Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-1 Kusunokicho, Chuo-ku, Kobe, Hyogo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshihiro","family":"Nishimura","sequence":"additional","affiliation":[{"name":"Division of Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-1 Kusunokicho, Chuo-ku, Kobe, Hyogo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazuyuki","family":"Kobayashi","sequence":"additional","affiliation":[{"name":"Division of Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-1 Kusunokicho, Chuo-ku, Kobe, Hyogo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2021,9,17]]},"reference":[{"key":"R1-20250504","doi-asserted-by":"crossref","first-page":"391","DOI":"10.7326\/0003-4819-93-3-391","article-title":"Continuous or nocturnal oxygen therapy in hypoxemic chronic obstructive lung disease: a clinical trial","volume":"93","year":"1980","journal-title":"Ann Intern Med"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1164\/arrd.1985.131.4.493","article-title":"Long-term oxygen therapy can reverse the progression of pulmonary hypertension in patients with chronic obstructive pulmonary disease","volume":"131","author":"Weitzenblum","year":"1985","journal-title":"Am Rev Respir Dis"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1378\/chest.91.1.15","article-title":"Demand oxygen delivery during exercise","volume":"91","author":"Tiep","year":"1987","journal-title":"Chest"},{"key":"R4-20250504","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1136\/thx.51.8.831","article-title":"Comparison of the efficacy of a demand oxygen delivery system with continuous low flow oxygen in subjects with stable COPD and severe oxygen desaturation on walking","volume":"51","author":"Roberts","year":"1996","journal-title":"Thorax"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"1191","DOI":"10.4187\/respcare.02937","article-title":"A pilot study comparing 2 oxygen delivery methods for patients\u2019 comfort and administration of oxygen","volume":"59","author":"Lee","year":"2014","journal-title":"Respir Care"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"382","DOI":"10.4187\/respcare.03470","article-title":"Oxygenation with a single portable pulse-dose oxygen-conserving device and combined stationary and portable oxygen delivery devices in subjects with COPD","volume":"60","author":"Y\u00e1\u00f1ez","year":"2015","journal-title":"Respir Care"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"e20010","DOI":"10.1097\/MD.0000000000020010","article-title":"Randomized cross-over trial of demand oxygen delivery system","volume":"99","author":"Nagano","year":"2020","journal-title":"Medicine (Baltimore)"},{"key":"R8-20250504","first-page":"26","article-title":"Home oxygen therapy","volume":"86","author":"Oishi","year":"2016","journal-title":"Iryokikigaku"},{"key":"R9-20250504","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1378\/chest.94.1.77","article-title":"Performance of a demand oxygen saver system during rest, exercise, and sleep in hypoxemic patients","volume":"94","author":"Bower","year":"1988","journal-title":"Chest"},{"key":"R10-20250504","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1097\/00000542-198501000-00020","article-title":"Noninvasive detection of profound arterial desaturations using a pulse oximetry device","volume":"62","author":"Mihm","year":"1985","journal-title":"Anesthesiology"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000027191","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T06:33:19Z","timestamp":1746340399000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000027191"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9,17]]},"references-count":10,"journal-issue":{"issue":"37","published-online":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000027191","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"type":"print","value":"0025-7974"},{"type":"electronic","value":"1536-5964"}],"subject":[],"published":{"date-parts":[[2021,9,17]]},"assertion":[{"value":"2021-03-20","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-08-20","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}