{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,11]],"date-time":"2026-02-11T14:22:44Z","timestamp":1770819764565,"version":"3.50.1"},"reference-count":37,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"39","license":[{"start":{"date-parts":[[2021,10,1]],"date-time":"2021-10-01T00:00:00Z","timestamp":1633046400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"funder":[{"DOI":"10.13039\/501100012544","name":"China Medical University, Taiwan","doi-asserted-by":"crossref","award":["CMU109-MF-117"],"award-info":[{"award-number":["CMU109-MF-117"]}],"id":[{"id":"10.13039\/501100012544","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Ministry of Science and Technology, Taiwan","award":["MOST 109-2221-E-039-005"],"award-info":[{"award-number":["MOST 109-2221-E-039-005"]}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>Abstract<\/jats:title>\n            <jats:p>Metacarpal shaft fractures are common hand fractures. Although bone plates possess strong fixation ability, they have several limitations. The use of headless compression screws for fracture repair has been reported, but their fixation ability has not been understood clearly.<\/jats:p>\n            <jats:p>This study aimed to compare the fixation ability of locked plate with that of headless compression screw for metacarpal fracture repair.<\/jats:p>\n            <jats:p>A total of 14 artificial metacarpal bones (Sawbones, Vashon, WA, USA) were subjected to transverse metacarpal shaft fractures and divided into 2 groups. The first group of bones was fixed using locked plates (LP group), whereas the second group was fixed using headless compression screws (HC group). A material testing machine was used to perform cantilever bending tests, whereby maximum fracture force and stiffness were measured. The fixation methods were compared by conducting a Mann\u2013Whitney <jats:italic toggle=\"yes\">U<\/jats:italic> test.<\/jats:p>\n            <jats:p>The maximum fracture force of the HC group (285.6\u200a\u00b1\u200a57.3\u200aN, median + interquartile range) was significantly higher than that of the LP group (227.8\u200a\u00b1\u200a37.5\u200aN; <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&lt;\u200a.05). The median of the HC group was 25.4% greater. However, no significant difference in stiffness (<jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&gt;\u200a.05) was observed between the HC (65.2\u200a\u00b1\u200a24.6\u200aN\/mm) and LP (61.7\u200a\u00b1\u200a19.7\u200aN\/mm) groups.<\/jats:p>\n            <jats:p>Headless compression screws exhibited greater fixability than did locked plates, particularly in its resistance to maximum fracture force.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000027375","type":"journal-article","created":{"date-parts":[[2021,10,1]],"date-time":"2021-10-01T19:36:12Z","timestamp":1633116972000},"page":"e27375","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":7,"title":["Comparison of the fixation ability of headless compression screws and locking plate for metacarpal shaft transverse fracture"],"prefix":"10.1097","volume":"100","author":[{"given":"Yung-Cheng","family":"Chiu","sequence":"first","affiliation":[{"name":"School of Medicine, China Medical University, Taichung, Taiwan"},{"name":"Department of Orthopedic Surgery, China Medical University Hospital, Taichung, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cheng-En","family":"Hsu","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Taichung Veterans General Hospital, Taichung, Taiwan"},{"name":"Sports Recreation and Health Management Continuing Studies-Bachelor's Degree Completion Program, Tunghai University, Taichung, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tsung-Yu","family":"Ho","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, China Medical University Hospital, Taichung, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yen-Nien","family":"Ting","sequence":"additional","affiliation":[{"name":"3D Printing Medical Research Center, China Medical University Hospital, Taichung, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bor-Han","family":"Wei","sequence":"additional","affiliation":[{"name":"Orthopedic Department, China Medical University Beigang Hospital, Yunlin County, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ming-Tzu","family":"Tsai","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Hungkuang University, Taichung, Taiwan, ROC"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jui-Ting","family":"Hsu","sequence":"additional","affiliation":[{"name":"School of Dentistry, College of Dentistry, China Medical University, Taichung, Taiwan"},{"name":"Department of Bioinformatics and Medical Engineering, Asia University, Taichung, Taiwan."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2021,10,1]]},"reference":[{"key":"R1-20250504","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1177\/1558944717731859","article-title":"Headless screw fixation of metacarpal neck fractures: a mechanical comparative analysis","volume":"14","author":"Jones","year":"2019","journal-title":"Hand"},{"key":"R2-20250504","first-page":"279","article-title":"Results of surgical treatment in metacarpal shaft fractures using low profile mini plates","volume":"21","author":"Aykut","year":"2015","journal-title":"Ulus Travma Acil Cerrahi Derg"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1007\/s11552-012-9442-0","article-title":"Incidence of metacarpal fractures in the US population","volume":"7","author":"Nakashian","year":"2012","journal-title":"Hand"},{"key":"R4-20250504","first-page":"22","article-title":"Exposing fractures of the proximal phalanx of the finger longitudinally through the dorsal extensor apparatus","volume":"15","author":"Pratt","year":"1959","journal-title":"Clin Orthop"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"1256","DOI":"10.1016\/j.jhsa.2010.05.013","article-title":"Ring and little finger metacarpal fractures: mechanisms, locations, and radiographic parameters","volume":"35","author":"Soong","year":"2010","journal-title":"J Hand Surg Am"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1142\/S0218810415500148","article-title":"Surgical outcomes of fifth metacarpal neck fractures\u2014a comparative analysis of dorsal plating versus tension band wiring","volume":"20","author":"Wong","year":"2015","journal-title":"Hand Surgery"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1007\/s00068-015-0507-y","article-title":"Open reduction and internal fixation versus percutaneous transverse Kirschner wire fixation for single, closed second to fifth metacarpal shaft fractures: a systematic review","volume":"42","author":"Greeven","year":"2016","journal-title":"Eur J Trauma Emerg Surg"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"111","DOI":"10.5435\/00124635-200003000-00005","article-title":"Operative treatment of metacarpal and phalangeal shaft fractures","volume":"8","author":"Kozin","year":"2000","journal-title":"J Am Acad Orthop Surg"},{"key":"R9-20250504","article-title":"Kirschner wire breakage during removal requiring retrieval","volume":"2016","author":"Wong","year":"2016","journal-title":"Case Rep Surg"},{"key":"R10-20250504","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1308\/003588407X155482","article-title":"A review of K-wire related complications in the emergency management of paediatric upper extremity trauma","volume":"89","author":"Sharma","year":"2007","journal-title":"Ann R Coll Surg Engl"},{"key":"R11-20250504","doi-asserted-by":"crossref","first-page":"e32933","DOI":"10.5812\/atr.32933","article-title":"Metacarpal neck fractures: a review of surgical indications and techniques","volume":"5","author":"Padegimas","year":"2016","journal-title":"Arch Trauma Res"},{"key":"R12-20250504","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1007\/s11552-015-9744-0","article-title":"Fixation for metacarpal neck fracture: a biomechanical study","volume":"10","author":"Malasitt","year":"2015","journal-title":"Hand"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1007\/s11552-013-9562-1","article-title":"Metacarpal fractures: treatment and complications","volume":"9","author":"Kollitz","year":"2014","journal-title":"Hand"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"1692","DOI":"10.1100\/2011\/465371","article-title":"Experimental fracture model versus osteotomy model in metacarpal bone plate fixation","volume":"11","author":"Ochman","year":"2011","journal-title":"ScientificWorldJournal"},{"key":"R15-20250504","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1016\/j.otsr.2010.02.009","article-title":"Fifth metacarpal neck fracture fixation: locking plate versus K-wire?","volume":"96","author":"Facca","year":"2010","journal-title":"Orthop Traumatol Surg Res"},{"key":"R16-20250504","doi-asserted-by":"crossref","first-page":"692","DOI":"10.1016\/j.jhsa.2014.11.023","article-title":"Minimally invasive fixation of fractures of the phalanges and metacarpals with intramedullary annulated headless compression screws","volume":"40","author":"del Pi\u00f1al","year":"2015","journal-title":"J Hand Surg Am"},{"key":"R17-20250504","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1053\/jhsu.2001.24145","article-title":"Mechanical testing of bioresorbable implants for use in metacarpal fracture fixation","volume":"26","author":"Bozic","year":"2001","journal-title":"J Hand Surg Am"},{"key":"R18-20250504","doi-asserted-by":"crossref","first-page":"187","DOI":"10.11604\/pamj.2014.18.187.3347","article-title":"Fractures of the neck of the fifth metacarpal bone, treated by percutaneous intramedullary nailing: surgical technique, radiological and clinical results study (28 cases)","volume":"18","author":"Boussakri","year":"2014","journal-title":"Pan Afr Med J"},{"key":"R19-20250504","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1016\/j.injury.2011.10.036","article-title":"Fractures of the neck of the fifth metacarpal bone. Medium-term results in 28 cases treated by percutaneous transverse pinning","volume":"43","author":"Potenza","year":"2012","journal-title":"Injury"},{"key":"R20-20250504","doi-asserted-by":"crossref","first-page":"e242","DOI":"10.1097\/BOT.0000000000000312","article-title":"The epidemiology of upper extremity fractures in the United States, 2009","volume":"29","author":"Karl","year":"2015","journal-title":"J Orthop Trauma"},{"key":"R21-20250504","doi-asserted-by":"crossref","first-page":"908","DOI":"10.1053\/jhsu.2001.26322","article-title":"The frequency and epidemiology of hand and forearm fractures in the United States","volume":"26","author":"Chung","year":"2001","journal-title":"J Hand Surg Am"},{"key":"R22-20250504","doi-asserted-by":"crossref","first-page":"1169","DOI":"10.2106\/00004623-195840050-00025","article-title":"A review and analysis of 11,000 fractures seen in a private practice of orthopaedic surgery 1937-1956","volume":"40","author":"Emmett","year":"1958","journal-title":"JBJS"},{"key":"R23-20250504","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1177\/1753193415601055","article-title":"Prophylactic antibiotics in open distal phalanx fractures: systematic review and meta-analysis","volume":"41","author":"Metcalfe","year":"2016","journal-title":"J Hand Surg Eur Vol"},{"key":"R24-20250504","doi-asserted-by":"crossref","first-page":"844","DOI":"10.1016\/S0363-5023(10)80147-9","article-title":"Pilon fractures of the proximal interphalangeal joint","volume":"16","author":"Stern","year":"1991","journal-title":"J Hand Surg Am"},{"key":"R25-20250504","doi-asserted-by":"crossref","first-page":"902","DOI":"10.1097\/00005373-199312000-00017","article-title":"Correction osteotomies of phalanges and metacarpals for rotational and angular malunion: a long-term follow-up and a review of the literature","volume":"35","author":"van der Lei","year":"1993","journal-title":"J Trauma"},{"key":"R26-20250504","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1097\/PRS.0000000000007056","article-title":"Closed metacarpal neck fractures: a review of resource use in operative and nonoperative management","volume":"146","author":"Hooper","year":"2020","journal-title":"Plast Reconstr Surg"},{"key":"R27-20250504","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1016\/j.jhsa.2011.01.023","article-title":"Complications of K-wire fixation in procedures involving the hand and wrist","volume":"36","author":"Hsu","year":"2011","journal-title":"J Hand Surg Am"},{"key":"R28-20250504","doi-asserted-by":"crossref","first-page":"474","DOI":"10.5435\/00124635-200708000-00004","article-title":"Percutaneous fixation of scaphoid fractures","volume":"15","author":"Gutow","year":"2007","journal-title":"J Am Acad Orthop Surg"},{"key":"R29-20250504","doi-asserted-by":"crossref","first-page":"2309499017716278","DOI":"10.1177\/2309499017716278","article-title":"Prospective study of surgical fixation of radial head fractures using cannulated headless compression screws for simple and complex radial head fractures","volume":"25","author":"Wu","year":"2017","journal-title":"J Orthop Surg (Hong Kong)"},{"key":"R30-20250504","first-page":"111","article-title":"Composite bone models in orthopaedic surgery research and education","volume":"22","author":"Elfar","year":"2014","journal-title":"J Am Acad Orthop Surg"},{"key":"R31-20250504","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1186\/s13018-018-0890-2","article-title":"New fixation approach for transverse metacarpal neck fracture: a biomechanical study","volume":"13","author":"Chiu","year":"2018","journal-title":"J Orthop Surg Res"},{"key":"R32-20250504","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1007\/s11552-014-9673-3","article-title":"Biomechanical evaluation of metacarpal fracture fixation: application of a 90 internal fixation model","volume":"10","author":"Watt","year":"2015","journal-title":"Hand"},{"key":"R33-20250504","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1007\/s11552-013-9544-3","article-title":"Plating of metacarpal fractures with locked or nonlocked screws, a biomechanical study: how many cortices are really necessary?","volume":"8","author":"Barr","year":"2013","journal-title":"Hand"},{"key":"R34-20250504","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1111\/os.12195","article-title":"Fixation of metacarpal shaft fractures: biomechanical comparison of intramedullary nail crossed K-Wires and plate-screw constructs","volume":"7","author":"Curtis","year":"2015","journal-title":"Orthop Surg"},{"key":"R35-20250504","doi-asserted-by":"crossref","DOI":"10.1155\/2014\/648787","article-title":"Biomechanical analysis of the efficacy of locking plates during cyclic loading in metacarpal fractures","volume":"2014","author":"Doht","year":"2014","journal-title":"ScientificWorldJournal"},{"key":"R36-20250504","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/j.cjtee.2016.06.009","article-title":"Biomechanical analysis of tension band wiring (TBW) of transverse fractures of patella","volume":"19","author":"Ali","year":"2016","journal-title":"Chin J Traumatol"},{"key":"R37-20250504","doi-asserted-by":"crossref","first-page":"S211","DOI":"10.1016\/j.jor.2015.10.003","article-title":"The headless compression screw\u2013technical challenges in scaphoid fracture fixation","volume":"12","author":"Ahmed","year":"2015","journal-title":"J Orthop"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000027375","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T05:11:18Z","timestamp":1746335478000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000027375"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10,1]]},"references-count":37,"journal-issue":{"issue":"39","published-online":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000027375","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,10,1]]},"assertion":[{"value":"2021-06-08","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-09-11","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}