{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,2]],"date-time":"2026-08-02T21:20:09Z","timestamp":1785705609417,"version":"3.56.0"},"reference-count":29,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2022,1,7]],"date-time":"2022-01-07T00:00:00Z","timestamp":1641513600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"funder":[{"DOI":"10.13039\/501100004332","name":"Seoul National University Hospital","doi-asserted-by":"crossref","award":["trauma research fund (No. 15-62420)"],"award-info":[{"award-number":["trauma research fund (No. 15-62420)"]}],"id":[{"id":"10.13039\/501100004332","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>Although preventing triceps fragment displacement is essential for treating an olecranon fracture, we frequently encounter situations in which only a few screws can be fixed to the triceps fragment. The aim of this study was to compare the stability of double-plate fixation and posterior plate fixation for olecranon fractures when the triceps fragment was small and only 2 screws could be inserted.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>A composite ulna model was used to simulate olecranon fracture. Four groups were formed consisting of double-plate and posterior plates with cortical and locking screws. The cyclic loading test was conducted for 500 cyclic loads of 5 to 50 N on a specimen to measure micromotion and displacement of the gap caused by light exercise. The load-to-failure test was performed by applying a load until fixation loss, defined as when the fracture gap increased by 2\u200amm or more or catastrophic failure occurred, to measure the maximum load.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Eight samples per group were tested through the pilot study. All groups were stable with a micromotion of &lt;0.5\u200amm. However, the mean micromotion showed significant differences between the 4 groups (<jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&lt;\u200a.001, Table 1\n                                 \n                                    \n                                       \n                                    \n                                 ). In the mean micromotion during exercise, posterior plating with cortical screws was the most stable (0.09\u200a\u00b1\u200a0.02\u200amm) while double-plating with cortical screws was the most unstable (0.42\u200a\u00b1\u200a0.11\u200amm). At the maximum load, posterior plating with locking screws was the strongest (205.3\u200a\u00b1\u200a2.8\u200aN) while double-plating with cortical screws was the weakest (143.3\u200a\u00b1\u200a27.1\u200aN). There was no significant difference in displacement after light exercise between the groups.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>This study showed that when 2 triceps screws were used, both groups were stable during light exercise, but posterior-plating was stronger than double-plating.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000028313","type":"journal-article","created":{"date-parts":[[2022,1,7]],"date-time":"2022-01-07T13:13:46Z","timestamp":1641561226000},"page":"e28313","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["Biomechanical comparison between double-plate fixation and posterior plate fixation for comminuted olecranon fracture using two triceps screws in synthetic bone model"],"prefix":"10.1097","volume":"101","author":[{"given":"Yohan","family":"Lee","sequence":"first","affiliation":[{"name":"College of Medicine, Seoul National University, Seoul, South Korea"},{"name":"Department of Orthopedic Surgery, Seoul National University Boramae Hospital, Seoul, South Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bong Wan","family":"Cho","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Seoul Jaeil Hospital, Pyeongtaek, South Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Min Bom","family":"Kim","sequence":"additional","affiliation":[{"name":"College of Medicine, Seoul National University, Seoul, South Korea"},{"name":"Department of Orthopedic Surgery, Seoul National University Hospital, Seoul, South Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2544-6183","authenticated-orcid":false,"given":"Young Ho","family":"Lee","sequence":"additional","affiliation":[{"name":"College of Medicine, Seoul National University, Seoul, South Korea"},{"name":"Department of Orthopedic Surgery, Seoul National University Hospital, Seoul, South Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,1,7]]},"reference":[{"key":"R1-20250504","doi-asserted-by":"crossref","first-page":"1149","DOI":"10.1016\/j.injury.2003.12.002","article-title":"Olecranon fractures in adults: factors influencing outcome","volume":"35","author":"Rommens","year":"2004","journal-title":"Injury"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"266","DOI":"10.5435\/00124635-200007000-00007","article-title":"Olecranon fractures: treatment options","volume":"8","author":"Hak","year":"2000","journal-title":"J Am Acad Orthop Surg"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1097\/BOT.0000000000001423","article-title":"Effect of elbow position on load to failure in olecranon fracture fixation: a biomechanical cadaveric study","volume":"33","author":"Lindeman","year":"2019","journal-title":"J Orthop Trauma"},{"key":"R4-20250504","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1016\/j.injury.2008.12.013","article-title":"Olecranon fractures","volume":"40","author":"Newman","year":"2009","journal-title":"Injury"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1097\/BOT.0b013e318214e64c","article-title":"An off-loading triceps suture for augmentation of plate fixation in comminuted osteoporotic fractures of the olecranon","volume":"26","author":"Izzi","year":"2012","journal-title":"J Orthop Trauma"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1097\/BOT.0b013e3180ce831e","article-title":"Congruent elbow plate fixation of olecranon fractures","volume":"21","author":"Anderson","year":"2007","journal-title":"J Orthop Trauma"},{"key":"R7-20250504","first-page":"149","article-title":"Management of fractures of the proximal ulna","volume":"21","author":"Rouleau","year":"2013","journal-title":"J Am Acad Orthop Surg"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1097\/00005131-200111000-00002","article-title":"Outcome of plate fixation of olecranon fractures","volume":"15","author":"Bailey","year":"2001","journal-title":"J Orthop Trauma"},{"key":"R9-20250504","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1016\/j.jse.2013.09.014","article-title":"Wound complications after distal humerus fracture fixation: incidence, risk factors, and outcome","volume":"23","author":"Lawrence","year":"2014","journal-title":"J Shoulder Elbow Surg"},{"key":"R10-20250504","doi-asserted-by":"crossref","first-page":"1466","DOI":"10.1016\/j.injury.2016.04.015","article-title":"Outcomes after plating of olecranon fractures: a multicenter evaluation","volume":"47","author":"De Giacomo","year":"2016","journal-title":"Injury"},{"key":"R11-20250504","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1016\/S1058-2746(96)80015-2","article-title":"Plate fixation of comminuted olecranon fractures: an in vitro biomechanical study","volume":"5","author":"King","year":"1996","journal-title":"J Shoulder Elbow Surg"},{"key":"R12-20250504","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1016\/j.jse.2005.06.003","article-title":"Comminuted olecranon fractures: a comparison of plating methods","volume":"15","author":"Gordon","year":"2006","journal-title":"J Shoulder Elbow Surg"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"1636","DOI":"10.1016\/j.injury.2016.05.010","article-title":"Reconstruction of Monteggia-like proximal ulna fractures using different fixation devices: a biomechanical study","volume":"47","author":"Wegmann","year":"2016","journal-title":"Injury"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"834","DOI":"10.1016\/j.jhsa.2017.05.014","article-title":"Plate osteosynthesis of proximal ulna fractures \u2013 a biomechanical micromotion analysis","volume":"42","author":"Hackl","year":"2017","journal-title":"J Hand Surg Am"},{"key":"R15-20250504","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1007\/s00402-020-03473-9","article-title":"Low-profile double plating versus dorsal LCP in stabilization of the olecranon fractures","volume":"141","author":"Hoelscher-Doht","year":"2020","journal-title":"Arch Orthop Trauma Surg"},{"key":"R16-20250504","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1016\/j.jhsa.2014.12.026","article-title":"Olecranon fractures with sagittal splits treated with dual fixation","volume":"40","author":"Morwood","year":"2015","journal-title":"J Hand Surg Am"},{"key":"R17-20250504","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1097\/BOT.0b013e318239273c","article-title":"Biomechanical evaluation of suture-augmented locking plate fixation for proximal third fractures of the olecranon","volume":"26","author":"Wild","year":"2012","journal-title":"J Orthop Trauma"},{"key":"R18-20250504","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.1016\/j.clinbiomech.2007.08.004","article-title":"A review of locking compression plate biomechanics and their advantages as internal fixators in fracture healing","volume":"22","author":"Miller","year":"2007","journal-title":"Clin Biomech"},{"key":"R19-20250504","doi-asserted-by":"crossref","first-page":"705","DOI":"10.5312\/wjo.v6.i9.705","article-title":"Comminuted olecranon fracture fixation with pre-contoured plate: comparison of composite and cadaver bones","volume":"6","author":"Hamilton","year":"2015","journal-title":"World J Orthop"},{"key":"R20-20250504","doi-asserted-by":"crossref","first-page":"e445","DOI":"10.1097\/BOT.0000000000001279","article-title":"Biomechanical assessment of locking plate fixation of comminuted proximal olecranon fractures","volume":"32","author":"Fantry","year":"2018","journal-title":"J Orthop Trauma"},{"key":"R21-20250504","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1016\/S1058-2746(96)80016-4","article-title":"Biomechanical analysis of tension band fixation for olecranon fracture treatment","volume":"5","author":"Kozin","year":"1996","journal-title":"J Shoulder Elbow Surg"},{"key":"R22-20250504","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1302\/0301-620X.93B2.24613","article-title":"Biomechanical comparison of interfragmentary compression in transverse fractures of the olecranon","volume":"93","author":"Wilson","year":"2011","journal-title":"J Bone Joint Surg Br"},{"key":"R23-20250504","doi-asserted-by":"crossref","first-page":"831","DOI":"10.2106\/00004623-200305000-00010","article-title":"Cyclic loading of olecranon fracture fixation constructs","volume":"85","author":"Hutchinson","year":"2003","journal-title":"J Bone Joint Surg Am"},{"key":"R24-20250504","doi-asserted-by":"crossref","first-page":"175","DOI":"10.3758\/BF03193146","article-title":"G\u2217 Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences","volume":"39","author":"Faul","year":"2007","journal-title":"Behav Res Methods"},{"key":"R25-20250504","doi-asserted-by":"crossref","first-page":"1519","DOI":"10.1016\/j.jse.2020.11.008","article-title":"Low-profile double plating of unstable osteoporotic olecranon fractures: a biomechanical comparative study","volume":"30","author":"Wagner","year":"2021","journal-title":"J Shoulder Elbow Surg"},{"key":"R26-20250504","doi-asserted-by":"crossref","first-page":"1313","DOI":"10.3928\/0147-7447-19931201-04","article-title":"The treatment of olecranon fractures by excision of fragments and repair of the extensor mechanism: historical review and report of 12 fractures","volume":"16","author":"Inhofe","year":"1993","journal-title":"Orthopedics"},{"key":"R27-20250504","doi-asserted-by":"crossref","first-page":"949","DOI":"10.2106\/JBJS.H.01873","article-title":"Contribution of the olecranon to elbow stability: an in vitro biomechanical study","volume":"92","author":"Bell","year":"2010","journal-title":"J Bone Joint Surg Am"},{"key":"R28-20250504","doi-asserted-by":"crossref","first-page":"1601","DOI":"10.1016\/j.otsr.2019.08.019","article-title":"Clinical evaluation of double-plate osteosynthesis for olecranon fractures: a retrospective case-control study","volume":"105","author":"Ellwein","year":"2019","journal-title":"Orthop Traumatol Surg Res"},{"key":"R29-20250504","doi-asserted-by":"crossref","first-page":"1275","DOI":"10.1016\/j.jse.2020.01.091","article-title":"Can low-profile double-plate osteosynthesis for olecranon fractures reduce implant removal? A retrospective multicenter study","volume":"29","author":"Ellwein","year":"2020","journal-title":"J Shoulder Elbow Surg"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000028313","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T04:11:16Z","timestamp":1746331876000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000028313"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,7]]},"references-count":29,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000028313","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,7]]},"assertion":[{"value":"2021-05-23","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-11-27","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}