{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,27]],"date-time":"2025-09-27T04:09:03Z","timestamp":1758946143818,"version":"3.40.4"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"51","license":[{"start":{"date-parts":[[2021,12,23]],"date-time":"2021-12-23T00:00:00Z","timestamp":1640217600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>Abstract<\/jats:title>\n            <jats:p>The aim of this study was to assess in-stent restenosis (ISR) of coronary artery for patients with CoCr stent using subtraction coronary computed tomography angiography (CCTA) with one-breath-hold scan on 320-row area detector CT, invasive coronary angiography (ICA) as clinical standard.<\/jats:p>\n            <jats:p>Patients who were referred for CCTA from January 2020 to May 2021 were retrospectively analyzed. Pre-contrast and CCTA was performed with dedicated one-breath-hold subtraction scan protocol and post processing to get subtracted-CCTA image without stent. Subjective image qualities and diagnosable rate were analyzed for CCTA and subtracted-CCTA respectively. The ISR degree of each stent was evaluated both on CCTA and subtracted-CCTA images. The receiver-operating characteristic curve with sensitivity, specificity, accuracy of CCTA, and subtracted-CCTA in the diagnosis of ISR were calculated with ICA as reference.<\/jats:p>\n            <jats:p>Forty patients with 85 CoCr coronary stents of 3 to 3.5\u200amm diameter with ICA confirmation within 1 month were finally included. Subtracted-CCTA showed more diagnosable segments of stent (91.76% [78\/85]) than those of CCTA (50.59% [43\/85]) (<jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&lt;\u200a.001). The subjective image quality score of CCTA was 2.23\u200a\u00b1\u200a1.32 while 3.41\u200a\u00b1\u200a0.90 on subtracted-CCTA (<jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&lt;\u200a.001). Both subtracted-CCTA and CCTA showed high consistency with ICA (Kappa\u200a=\u200a0.795 and 0.918 respectively). The area under the curve was 0.607 for CCTA and 0.757 for subtracted-CCTA (<jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&lt;\u200a.001) for stent based diagnose, respectively. The sensitivity, specificity, accuracy of CCTA, and subtracted-CCTA were 90.0%, 97.0%, 95.3%, and 87.5%, 100.0%, 97.43%, respectively.<\/jats:p>\n            <jats:p>Subtracted-CCTA showed improved diagnose performance for ISR, which potentially reduce further follow-up ICA procedures for patients with CoCr stents.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000028345","type":"journal-article","created":{"date-parts":[[2021,12,23]],"date-time":"2021-12-23T19:09:25Z","timestamp":1640286565000},"page":"e28345","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["The usefulness of subtraction coronary computed tomography angiography for in-stent restenosis assessment of patients with CoCr stent using 320-row area detector CT"],"prefix":"10.1097","volume":"100","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2295-107X","authenticated-orcid":false,"given":"Jian","family":"Li","sequence":"first","affiliation":[{"name":"Department of Radiology, Shaanxi Provincial People's Hospital, Xi\u2019an, Shaanxi, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Man-Tao","family":"Guo","sequence":"additional","affiliation":[{"name":"Department of Radiology, Xianyang Hospital of Yan\u2019an University, Xianyang, Shaanxi, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiao","family":"Yang","sequence":"additional","affiliation":[{"name":"Department of Radiology, Shaanxi Provincial People's Hospital, Xi\u2019an, Shaanxi, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fang","family":"Gao","sequence":"additional","affiliation":[{"name":"Department of Radiology, Shaanxi Provincial People's Hospital, Xi\u2019an, Shaanxi, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Na","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Radiology, Shaanxi Provincial People's Hospital, Xi\u2019an, Shaanxi, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ming-Gang","family":"Huang","sequence":"additional","affiliation":[{"name":"Department of Radiology, Shaanxi Provincial People's Hospital, Xi\u2019an, Shaanxi, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2021,12,23]]},"reference":[{"key":"R1-20250504","first-page":"211","article-title":"In-stent restenosis","volume":"5","author":"Lee","year":"2016","journal-title":"Interv Cardiol Clin"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"33","DOI":"10.3390\/jpm8040033","article-title":"40\u200ayears of percutaneous coronary intervention: history and future directions","volume":"8","author":"Canfield","year":"2018","journal-title":"J Pers Med"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1161\/CIRCULATIONAHA.119.039797","article-title":"Guiding principles for chronic total occlusion percutaneous coronary intervention","volume":"140","author":"Brilakis","year":"2019","journal-title":"Circulation"},{"issue":"(suppl)","key":"R4-20250504","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1007\/s10554-014-0417-9","article-title":"The evolution and investigation of native coronary arteries in patients after coronary stent implantation: a study by 320-detector CT angiography","volume":"30","author":"Juan","year":"2014","journal-title":"Int J Cardiovasc Imaging"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1016\/j.jcct.2019.06.005","article-title":"How accurate is atherosclerosis imaging by coronary computed tomography angiography?","volume":"13","author":"Nakanishi","year":"2019","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"12","DOI":"10.25259\/JCIS_153_2019","article-title":"Diagnostic value of intraluminal stent enhancement in estimating coronary in-stent restenosis","volume":"10","author":"Nogourani","year":"2020","journal-title":"J Clin Imaging Sci"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"848","DOI":"10.1136\/hrt.2007.126474","article-title":"Dual source coronary computed tomography angiography for detecting in-stent restenosis","volume":"94","author":"Pugliese","year":"2008","journal-title":"Heart"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1016\/j.jcct.2015.03.016","article-title":"Feasibility of coronary calcium and stent image subtraction using 320-detector row CT angiography","volume":"9","author":"Fuchs","year":"2015","journal-title":"J Cardiovasc Comput Tomogr"},{"issue":"(suppl)","key":"R11-20250504","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1002\/ccd.28705","article-title":"Two-year follow-up of a randomized multicenter study comparing a drug-coated balloon with a drug-eluting stent in native small coronary vessels: the RESTORE small vessel disease china trial","volume":"95","author":"Tian","year":"2020","journal-title":"Catheter Cardiovasc Interv"},{"key":"R12-20250504","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.acra.2016.08.025","article-title":"A new contrast enhancement protocol for subtraction coronary computed tomography requiring a short breath-holding time","volume":"24","author":"Yamaguchi","year":"2017","journal-title":"Acad Radiol"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"1170","DOI":"10.1016\/j.acra.2016.04.012","article-title":"Modified subtraction coronary CT angiography method for patients unable to perform long breath-holds: a preliminary study","volume":"23","author":"Yoshioka","year":"2016","journal-title":"Acad Radiol"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.jjcc.2018.05.015","article-title":"The usefulness of low radiation dose subtraction coronary computed tomography angiography for patients with calcification using 320-row area detector CT","volume":"73","author":"Takamura","year":"2019","journal-title":"J Cardiol"},{"key":"R15-20250504","doi-asserted-by":"crossref","first-page":"943","DOI":"10.1007\/s10554-011-9902-6","article-title":"Influence of coronary calcification on the diagnosticaccuracy of 64-slice computed tomography coronary angiography: a systematic review andmeta-analysis","volume":"28","author":"Abdulla","year":"2012","journal-title":"Int J Cardiovasc Imaging"},{"key":"R16-20250504","doi-asserted-by":"crossref","first-page":"1090","DOI":"10.21037\/cdt.2020.04.04","article-title":"Dual-energy CT and coronary imaging","volume":"10","author":"Kay","year":"2020","journal-title":"Cardiovasc Diagn Ther"},{"key":"R17-20250504","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.ejrad.2018.05.028","article-title":"Dual-energy CT of the heart current and future status","volume":"105","author":"Albrecht","year":"2018","journal-title":"Eur J Radiol"},{"key":"R18-20250504","doi-asserted-by":"crossref","first-page":"02","DOI":"10.1186\/s13244-019-0685-y","article-title":"Ultra-high-resolution subtraction CT angiography in the follow-up of treated intracranial aneurysms","volume":"10","author":"Meijer","year":"2019","journal-title":"Insights Imaging"},{"key":"R19-20250504","doi-asserted-by":"crossref","first-page":"20170631","DOI":"10.1259\/bjr.20170631","article-title":"Subtraction CT angiography in head and neck with low radiation and contrast dose dual-energy spectral CT using rapid kV-switching technique","volume":"91","author":"Ma","year":"2018","journal-title":"Br J Radiol"},{"key":"R20-20250504","doi-asserted-by":"crossref","first-page":"1635","DOI":"10.1007\/s10554-015-0746-3","article-title":"Subtraction coronary computed tomography in patients with severe calcification","volume":"31","author":"Amanuma","year":"2015","journal-title":"Int J Cardiovasc Imaging"},{"key":"R21-20250504","doi-asserted-by":"crossref","first-page":"4077","DOI":"10.1007\/s00330-018-5418-y","article-title":"Subtraction CT angiography improves evaluation of significant coronary artery disease in patients with severe calcifications or stents-the C-Sub 320 multicenter trial","volume":"28","author":"Fuchs","year":"2018","journal-title":"Eur Radiol"},{"key":"R22-20250504","doi-asserted-by":"crossref","first-page":"3208","DOI":"10.1007\/s00330-015-4130-4","article-title":"Reliability of a new method for coronary artery calcium or metal subtraction by 320-row cardiac CT","volume":"26","author":"Vilades Medel","year":"2016","journal-title":"Eur Radiol"},{"key":"R23-20250504","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1007\/s10554-015-0826-4","article-title":"Assessment of coronary in-stent restenosis: value of subtractioncoronary computed tomography angiography","volume":"32","author":"Amanuma","year":"2016","journal-title":"Int J Cardiovasc Imaging"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000028345","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T06:06:22Z","timestamp":1746338782000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000028345"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12,23]]},"references-count":21,"journal-issue":{"issue":"51","published-online":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000028345","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"type":"print","value":"0025-7974"},{"type":"electronic","value":"1536-5964"}],"subject":[],"published":{"date-parts":[[2021,12,23]]},"assertion":[{"value":"2021-08-16","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-12-01","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}