{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,5]],"date-time":"2025-05-05T04:01:56Z","timestamp":1746417716083,"version":"3.40.4"},"reference-count":12,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","license":[{"start":{"date-parts":[[2022,1,28]],"date-time":"2022-01-28T00:00:00Z","timestamp":1643328000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Rationale:<\/jats:title>\n            <jats:p>Resurfacing arthroplasty using the J&amp;J DePuy ASR system was withdrawn from surgical treatment due to the necessity of frequent revision procedures after its application. There have been many studies concerning treatment of acetabular bone loss using different operating techniques. However, we felt that data of custom - made implant usage in such cases is highly insufficient, and there is lack of evidence on its application in treatment of loosening of the previous implant. The aim of the study was to evaluate the effectiveness of surgical treatment with a custom-made implant in a patient with extensive acetabular bone loss after aseptic loosening of the acetabular component of the J&amp;J DePuy ASR surface prosthesis in the early period of observation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patient concerns:<\/jats:title>\n            <jats:p>A 74-year-old patient was taken to the Orthopaedic Trauma Emergency Room due to increasing pain in the right hip for about 3\u200amonths. Nine years earlier he underwent resurfacing arthroplasty of the right hip using the J&amp;J DePuy ASR method.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Diagnoses:<\/jats:title>\n            <jats:p>The imaging diagnostics (X-ray, computed tomography, ultrasound) revealed the presence of a pseudotumor and lysis around the acetabular implant, which caused a fracture in the acetabulum.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Interventions:<\/jats:title>\n            <jats:p>Revision arthroplasty of the right hip joint was performed with the removal of the ASR implant. During the procedure extensive bone defects were visualized, preventing the insertion of the revision acetabulum. After extensive plasticization of the defects with the use of allogeneic cancellous chips the \u201changing hip\u201d was left with the intention of making another attempt to insert the implant after the reconstitution of the acetabular bone. A computed tomography examination 2.5\u200ayears after the ASR removal revealed the lack of an adequate degree of bone remodeling for the planned implant. Arthroplasty using custom - made aMace Acetabular Revision System by Materialize was performed 3\u200ayears after the removal of ASR.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Outcomes:<\/jats:title>\n            <jats:p>Optimal implant adherence to the bone base and full osseointegration with the pelvic bone bearing has been achieved. Significant improvement in clinical parameters has been noted, with no complications in the postoperative period.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Lessons:<\/jats:title>\n            <jats:p>The use of an individual custom-made implant in extensive acetabular bone loss after aseptic loosening of the acetabular component of the J&amp;J DePuy ASR surface prosthesis in patients is an effective method of surgical treatment.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000028475","type":"journal-article","created":{"date-parts":[[2022,1,28]],"date-time":"2022-01-28T14:01:50Z","timestamp":1643378510000},"page":"e28475","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Revision arthroplasty using a custom-made implant in the course of acetabular loosening of the J&amp;J DePuy ASR replacement system - case report"],"prefix":"10.1097","volume":"101","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5811-0937","authenticated-orcid":false,"given":"Aleksander","family":"Augustyn","sequence":"first","affiliation":[{"name":"District Hospital of Orthopaedics and Trauma Surgery in Piekary \u015al\u0105skie, Bytomska St. 62, Piekary \u015al\u0105skie, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomasz","family":"Sto\u0142tny","sequence":"additional","affiliation":[{"name":"District Hospital of Orthopaedics and Trauma Surgery in Piekary \u015al\u0105skie, Bytomska St. 62, Piekary \u015al\u0105skie, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dominika","family":"Rokicka","sequence":"additional","affiliation":[{"name":"Department of Internal Diseases, Diabetology, and Cardiometabolic Diseases, School of Medicine with the Division of Dentistry in Zabrze, Medical University of Silesia in Katowice, Silesian Centre for Heart Diseases in Zabrze, M. Curie-Sk\u0142odowskiej St. 9, Zabrze, Poland."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marta","family":"Wr\u00f3bel","sequence":"additional","affiliation":[{"name":"Department of Internal Diseases, Diabetology, and Cardiometabolic Diseases, School of Medicine with the Division of Dentistry in Zabrze, Medical University of Silesia in Katowice, Silesian Centre for Heart Diseases in Zabrze, M. Curie-Sk\u0142odowskiej St. 9, Zabrze, Poland."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jan","family":"Paj\u0105k","sequence":"additional","affiliation":[{"name":"District Hospital of Orthopaedics and Trauma Surgery in Piekary \u015al\u0105skie, Bytomska St. 62, Piekary \u015al\u0105skie, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Krystian","family":"Werner","sequence":"additional","affiliation":[{"name":"District Hospital of Orthopaedics and Trauma Surgery in Piekary \u015al\u0105skie, Bytomska St. 62, Piekary \u015al\u0105skie, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Karol","family":"Ochocki","sequence":"additional","affiliation":[{"name":"District Hospital of Orthopaedics and Trauma Surgery in Piekary \u015al\u0105skie, Bytomska St. 62, Piekary \u015al\u0105skie, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Krzysztof","family":"Strojek","sequence":"additional","affiliation":[{"name":"Department of Internal Diseases, Diabetology, and Cardiometabolic Diseases, School of Medicine with the Division of Dentistry in Zabrze, Medical University of Silesia in Katowice, Silesian Centre for Heart Diseases in Zabrze, M. Curie-Sk\u0142odowskiej St. 9, Zabrze, Poland."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bogdan","family":"Koczy","sequence":"additional","affiliation":[{"name":"District Hospital of Orthopaedics and Trauma Surgery in Piekary \u015al\u0105skie, Bytomska St. 62, Piekary \u015al\u0105skie, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2022,1,28]]},"reference":[{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1186\/s40504-014-0019-2","article-title":"Precaution, governance and the failure of the medical implants: the ASRTm hip in the UK","volume":"10","author":"Wienroth","year":"2014","journal-title":"Life Sci Soc Policy"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1007\/s00132-020-03909-5","article-title":"Custom-made acetabular implants in revision total hip arthroplasty","volume":"49","author":"Von Lewinski","year":"2020","journal-title":"Orthopade"},{"key":"R4-20250504","doi-asserted-by":"crossref","first-page":"3725","DOI":"10.1007\/s11999-013-3264-4","article-title":"Classifications in brief: Paprosky classification of acetabular bone loss","volume":"471","author":"Telleria","year":"2013","journal-title":"Clin Orthop Relat Res"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"570","DOI":"10.1302\/2046-3758.710.BJR-2017-0319.R1","article-title":"Use of Stimulan absorbable calcium sulphate beads in revision lower limb arthroplasty: safety profile and complication rates","volume":"7","author":"Kallala","year":"2018","journal-title":"Bone Joint Res"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"2287","DOI":"10.2106\/JBJS.J.01727","article-title":"Five-year results of the ASR XL acetabular system and the ASR Hip Resurfacing sytem","volume":"93","author":"De Steiger","year":"2011","journal-title":"J Bone Joint Surg Am"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"128","DOI":"10.2106\/JBJS.H.00155","article-title":"The epidemiology of revision total hip arthroplasty in the United States","volume":"91","author":"Bozic","year":"2009","journal-title":"J Bone Joint Surg Am"},{"key":"R9-20250504","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1177\/112070000501500411","article-title":"Bone loss at hip resurfacing: a comparison with total hip arthroplasty","volume":"15","author":"Crawford","year":"2005","journal-title":"Hip Int"},{"key":"R10-20250504","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1302\/0301-620X.92B8.24194","article-title":"Optimal acetabular orientation for hip resurfacing","volume":"92","author":"Grammatopoulos","year":"2010","journal-title":"J Bone Joint Surg Br"},{"key":"R11-20250504","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.jcot.2019.11.004","article-title":"Acetabular reconstruction in revision total hip arthroplasty","volume":"11","author":"Fryhofer","year":"2020","journal-title":"J Clin Orthop Trauma"},{"key":"R12-20250504","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1177\/1120700019874442","article-title":"lsolated acetabular revisions of articular surface replacement (ASR) XL implants with highly porous titanium cups and Delta bearings","volume":"31","author":"Castagnini","year":"2021","journal-title":"Hip Int"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1007\/s00402-019-03318-0","article-title":"Mid-term results after revision total hip arthroplasty with custom-made acetabular implants in patients with Paprosky III acetabular bone loss","volume":"140","author":"Fr\u00f6schen","year":"2020","journal-title":"Arch Orthop Trauma Surg"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1177\/1457496914568408","article-title":"Acetabular reconstruction with impaction bone grafting and cemented polyethylene socket in total hip revision arthroplasty","volume":"104","author":"Kostensalo","year":"2015","journal-title":"Scand J Surg"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000028475","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T04:27:12Z","timestamp":1746332832000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000028475"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,28]]},"references-count":12,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000028475","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"type":"print","value":"0025-7974"},{"type":"electronic","value":"1536-5964"}],"subject":[],"published":{"date-parts":[[2022,1,28]]},"assertion":[{"value":"2021-11-09","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-12-15","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}