{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T17:58:47Z","timestamp":1793901527330,"version":"4.8.0"},"reference-count":33,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","license":[{"start":{"date-parts":[[2022,3,4]],"date-time":"2022-03-04T00:00:00Z","timestamp":1646352000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>This meta-analysis was conducted to compare the safety and diagnostic performance between computed tomography (CT)-guided core needle biopsy (CNB) and fine-needle aspiration biopsy (FNAB) in lung nodules\/masses patients.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>All relevant studies in the Pubmed, Embase, and Cochrane Library databases that were published as of June 2020 were identified. RevMan version 5.3 was used for all data analyses.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>In total, 9 relevant studies were included in the present meta-analysis. These studies were all retrospective and analyzed outcomes associated with 2175 procedures, including both CT-guided CNB (n\u200a=\u200a819) and FNAB (n\u200a=\u200a1356) procedures. CNB was associated with significantly higher sample adequacy rates than was FNAB (95.7% vs 85.8%, OR: 0.26; <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a&lt;\u200a.00001), while diagnostic accuracy rates did not differ between these groups (90.1% vs 87.6%, OR: 0.8; <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a=\u200a.46). In addition, no differences in rates of pneumothorax (28.6% vs 23.0%, OR: 1.15; <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a=\u200a.71), hemorrhage (17.3% vs 20.1%, OR: 0.91; <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a=\u200a.62), and chest tube insertion (5.9% vs 4.9%, OR: 1.01; <jats:italic toggle=\"yes\">P<\/jats:italic>\u200a=\u200a.97) were detected between these groups. Significant heterogeneity among included studies was detected for the diagnostic accuracy (I<jats:sup>2<\/jats:sup>\u200a=\u200a57%) and pneumothorax (I<jats:sup>2<\/jats:sup>\u200a=\u200a77%) endpoints. There were no significant differences between CNB and FNAB with respect to diagnostic accuracy rates for lung nodules (<jats:italic toggle=\"yes\">P<\/jats:italic>\u200a=\u200a.90). In addition, we detected no evidence of significant publication bias.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>CT-guided CNB could achieve better sample adequacy than FNAB did during the lung biopsy procedure. However, the CNB did not show any superiorities in items of diagnostic accuracy and safety.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000029016","type":"journal-article","created":{"date-parts":[[2022,3,4]],"date-time":"2022-03-04T13:03:19Z","timestamp":1646398999000},"page":"e29016","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":20,"title":["Comparison between computed tomography-guided core and fine needle lung biopsy"],"prefix":"10.1097","volume":"101","author":[{"given":"Yong","family":"Li","sequence":"first","affiliation":[{"name":"Sichuan Key Laboratory of Medical Imaging and Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fang","family":"Yang","sequence":"additional","affiliation":[{"name":"Sichuan Key Laboratory of Medical Imaging and Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7995-1156","authenticated-orcid":false,"given":"Ya-Yong","family":"Huang","sequence":"additional","affiliation":[{"name":"Department of Radiology, Xuzhou Central Hospital, 199 South Jiefang Road, Xuzhou, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Cao","sequence":"additional","affiliation":[{"name":"Department of Radiology, Xuzhou Central Hospital, 199 South Jiefang Road, Xuzhou, China."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,3,4]]},"reference":[{"key":"R1-20250504","doi-asserted-by":"crossref","first-page":"823","DOI":"10.1148\/radiol.2253011465","article-title":"CT-guided percutaneous fine-needle aspiration biopsy of small (< or\u200a=\u200a1-cm) pulmonary lesions","volume":"225","author":"Wallace","year":"2002","journal-title":"Radiology"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"1130","DOI":"10.1016\/j.acra.2016.05.013","article-title":"Instituting a low-dose CT-guided lung biopsy protocol","volume":"23","author":"Kallianos","year":"2016","journal-title":"Acad Radiol"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"909","DOI":"10.1177\/0284185113485937","article-title":"Comparison of lung lesion biopsies between low-dose CT-guided and conventional CT-guided techniques","volume":"54","author":"Meng","year":"2013","journal-title":"Acta Radiol"},{"key":"R4-20250504","doi-asserted-by":"crossref","first-page":"323","DOI":"10.3348\/kjr.2018.0064","article-title":"Analysis of complications of percutaneous transthoracic needle biopsy using CT-guidance modalities in a multicenter cohort of 10568 biopsies","volume":"20","author":"Yoon","year":"2019","journal-title":"Korean J Radiol"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"333","DOI":"10.21037\/jtd.2017.02.16","article-title":"CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing","volume":"9","author":"Tian","year":"2017","journal-title":"J Thorac Dis"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1097\/01.RVI.0000150032.12842.9E","article-title":"Efficacy of manual aspiration immediately after complicated pneumothorax in CT-guided lung biopsy","volume":"16","author":"Yamagami","year":"2005","journal-title":"J Vasc Interv Radiol"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"1029","DOI":"10.1016\/j.ejrad.2011.01.064","article-title":"CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: accuracy, complications and radiation dose","volume":"81","author":"Prosch","year":"2012","journal-title":"Eur J Radiol"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1097\/JTO.0b013e318233d7dd","article-title":"Percutaneous computed tomography-guided coaxial core biopsy for small pulmonary lesions with ground-glass attenuation","volume":"7","author":"Lu","year":"2012","journal-title":"J Thorac Oncol"},{"key":"R9-20250504","doi-asserted-by":"crossref","first-page":"1071","DOI":"10.1007\/s11547-013-0965-4","article-title":"Predictive factors of diagnostic accuracy of CT-guided transthoracic fine-needle aspiration for solid noncalcified, subsolid and mixed pulmonary nodules","volume":"118","author":"De Filippo","year":"2013","journal-title":"Radiol Med"},{"key":"R10-20250504","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1097\/RCT.0000000000001044","article-title":"Computed tomography fluoroscopy-guided versus conventional computed tomography-guided lung biopsy: a systematic review and meta-analysis","volume":"44","author":"Fu","year":"2020","journal-title":"J Comput Assist Tomogr"},{"key":"R11-20250504","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1016\/S1051-0443(98)70383-5","article-title":"Real-time CT fluoroscopy for guidance of percutaneous drainage procedures","volume":"9","author":"Froelich","year":"1998","journal-title":"J Vasc Interv Radiol"},{"key":"R12-20250504","doi-asserted-by":"crossref","first-page":"1387","DOI":"10.1007\/s00330-006-0152-2","article-title":"Accuracy and complications in computed tomography fluoroscopy-guided needle biopsies of lung masses","volume":"16","author":"Heck","year":"2006","journal-title":"Eur Radiol"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1007\/s002700010067","article-title":"Percutaneous CT-guided biopsy of the lung: comparison between aspiration and automated cutting needles using a coaxial technique","volume":"23","author":"Laurent","year":"2000","journal-title":"Cardiovasc Intervent Radiol"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1016\/S0720-048X(03)00216-X","article-title":"Transthoracic CT-guided biopsy with multiplanar reconstruction image improves diagnostic accuracy of solitary pulmonary nodules","volume":"51","author":"Ohno","year":"2004","journal-title":"Eur J Radiol"},{"key":"R15-20250504","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1590\/S1516-31802006000100003","article-title":"Computed tomography guided needle biopsy: experience from 1,300 procedures","volume":"124","author":"Chojniak","year":"2006","journal-title":"Sao Paulo Med J"},{"key":"R16-20250504","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1016\/S0873-2159(15)30448-7","article-title":"CT-guided percutaneous transthoracic biopsy in the evaluation of undetermined pulmonary lesions","volume":"12","author":"Louren\u00e7o","year":"2006","journal-title":"Rev Port Pneumol"},{"key":"R17-20250504","doi-asserted-by":"crossref","first-page":"19","DOI":"10.2478\/v10019-012-0004-4","article-title":"Percutaneous transthoracic CT guided biopsies of lung lesions; fine needle aspiration biopsy versus core biopsy","volume":"46","author":"Beslic","year":"2012","journal-title":"Radiol Oncol"},{"key":"R18-20250504","first-page":"1553","article-title":"Diagnostic efficacy of computed tomography-guided transthoracic needle aspiration and biopsy in patients with pulmonary disease","volume":"6","author":"Tuna","year":"2013","journal-title":"Onco Targets Ther"},{"key":"R19-20250504","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1007\/s11547-013-0360-1","article-title":"Trans-thoracic biopsy of lung lesions: FNAB or CNB? Our experience and review of the literature","volume":"119","author":"Capalbo","year":"2014","journal-title":"Radiol Med"},{"key":"R20-20250504","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1016\/j.jvir.2016.01.134","article-title":"Diagnostic accuracy and safety of CT-guided percutaneous transthoracic needle biopsies: 14-gauge versus 22-gauge needles","volume":"27","author":"Ocak","year":"2016","journal-title":"J Vasc Interv Radiol"},{"key":"R21-20250504","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1016\/j.carj.2015.10.005","article-title":"Transthoracic computed tomography-guided lung nodule biopsy: comparison of core needle and fine needle aspiration techniques","volume":"67","author":"Sangha","year":"2016","journal-title":"Can Assoc Radiol J"},{"key":"R22-20250504","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.crad.2015.09.009","article-title":"The diagnostic accuracy of CT-guided percutaneous core needle biopsy and fine needle aspiration in pulmonary lesions: a meta-analysis","volume":"71","author":"Zhang","year":"2016","journal-title":"Clin Radiol"},{"key":"R23-20250504","doi-asserted-by":"crossref","first-page":"1067","DOI":"10.1097\/ACM.0000000000000786","article-title":"Appraising the quality of medical education research methods: the Medical Education Research Study Quality Instrument and the Newcastle\u2013Ottawa Scale-Education","volume":"90","author":"Cook","year":"2015","journal-title":"Acad Med"},{"key":"R24-20250504","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1007\/s00330-010-1936-y","article-title":"CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance","volume":"21","author":"Kim","year":"2011","journal-title":"Eur Radiol"},{"key":"R25-20250504","doi-asserted-by":"crossref","first-page":"e0154","DOI":"10.1097\/MD.0000000000010154","article-title":"Computed tomography-guided percutaneous transthoracic needle biopsy for solitary pulmonary nodules in diameter less than 20\u200amm","volume":"97","author":"Xu","year":"2018","journal-title":"Medicine (Baltimore)"},{"key":"R26-20250504","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1007\/s12032-016-0871-4","article-title":"Extra-pleuric coaxial system for CT-guided percutaneous fine needle aspiration biopsy (FNAB) of small (\u2264 20\u200amm) lung nodules: a novel technique using multiplanar reconstruction (MPR) images","volume":"34","author":"Capasso","year":"2017","journal-title":"Med Oncol"},{"key":"R27-20250504","doi-asserted-by":"crossref","first-page":"e8703","DOI":"10.1097\/MD.0000000000008703","article-title":"Computed tomography-guided percutaneous cutting needle biopsy for small (\u226420\u200amm) lung nodules","volume":"96","author":"Li","year":"2017","journal-title":"Medicine (Baltimore)"},{"key":"R28-20250504","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1111\/crj.13172","article-title":"Computed tomography-guided biopsy for sub-centimetre lung nodules: technical success and diagnostic accuracy","volume":"14","author":"Li","year":"2020","journal-title":"Clin Respir J"},{"key":"R29-20250504","doi-asserted-by":"crossref","first-page":"e43","DOI":"10.1016\/j.crad.2012.09.008","article-title":"CT-guided percutaneous core needle biopsy for small (\u226420\u200amm) pulmonary lesions","volume":"68","author":"Li","year":"2013","journal-title":"Clin Radiol"},{"key":"R30-20250504","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1097\/01.RVI.0000071087.76348.C7","article-title":"Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: retrospective analysis of 631 procedures","volume":"14","author":"Yeow","year":"2003","journal-title":"J Vasc Interv Radiol"},{"key":"R31-20250504","doi-asserted-by":"crossref","first-page":"1356","DOI":"10.1007\/s00330-008-0893-1","article-title":"Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy","volume":"18","author":"Khan","year":"2008","journal-title":"Eur Radiol"},{"key":"R32-20250504","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1007\/s00270-015-1167-3","article-title":"Pneumothorax complicating coaxial and non-coaxial CT-guided lung biopsy: comparative analysis of determining risk factors and management of pneumothorax in a retrospective review of 650 patients","volume":"39","author":"Nour-Eldin","year":"2016","journal-title":"Cardiovasc Intervent Radiol"},{"key":"R33-20250504","doi-asserted-by":"crossref","first-page":"W678","DOI":"10.2214\/AJR.10.4659","article-title":"Complications of CT-guided percutaneous needle biopsy of the chest: prevention and management","volume":"196","author":"Wu","year":"2011","journal-title":"AJR Am J Roentgenol"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000029016","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T04:05:39Z","timestamp":1746331539000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000029016"}},"subtitle":["A meta-analysis"],"short-title":[],"issued":{"date-parts":[[2022,3,4]]},"references-count":33,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000029016","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,3,4]]},"assertion":[{"value":"2020-11-04","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-02-17","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}