{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T15:37:18Z","timestamp":1787585838806,"version":"build-2736575974"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"28","license":[{"start":{"date-parts":[[2022,7,15]],"date-time":"2022-07-15T00:00:00Z","timestamp":1657843200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>We aimed to compare the reliability of laboratory blood tests using 2 sampling methods, via a peripheral venous catheter (PVC) vs direct venipuncture stab (DVS), we evaluated the effect of time elapsed since PVC insertion, PVC diameter, and administration of saline and\/or antibiotic infusion through PVC on the blood test results.<\/jats:p>\n          <jats:p>A prospective comparative study was conducted between May 2018 and July 2019. Patients aged\u2005\u2265\u200518 years and admitted to our department with a 20G\/22G PVC inserted within the last 24 hours were enrolled.<\/jats:p>\n          <jats:p>Blood samples were collected from each participant in the morning, and a second sample was drawn using PVC. Dependent variables included the percentage of hemolysis, failure rate, complete blood count, biochemical testing parameters, and coagulation functions.<\/jats:p>\n          <jats:p>A total of 211 patients participated in the study. In total, 237 blood tests were conducted, of which 167 were performed on day 1 and the remaining on day 2, with a second blood sample collected from 26 patients on day 2. Twenty-one participants received 22G PVC, and 23 participants received active infusion. No significant differences were found in failure rates when each subgroup was compared with the primary day 1 group. The intraclass correlation coefficient indicated significant correlations among all the indices in all groups.<\/jats:p>\n          <jats:p>Both blood sampling methods (PVC and direct venipuncture) can be used interchangeably for routine laboratory tests on days 1 and 2 after PVC insertion using 20G\/22G PVC or infused PVC.<\/jats:p>","DOI":"10.1097\/md.0000000000029268","type":"journal-article","created":{"date-parts":[[2022,9,8]],"date-time":"2022-09-08T15:05:48Z","timestamp":1662649548000},"page":"e29268","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Reliability of blood tests taken from the peripheral intravenous catheter"],"prefix":"10.1097","volume":"101","author":[{"given":"Idan","family":"Ben Shabat","sequence":"first","affiliation":[{"name":"Internal Medicine Division, Soroka University Medical Center, Ben-Gurion University of the Negev, Beer-Sheva, Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michal Hoffman","family":"Ben Shabat","sequence":"additional","affiliation":[{"name":"Internal Medicine Division, Soroka University Medical Center, Ben-Gurion University of the Negev, Beer-Sheva, Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shai","family":"Ben Abraham","sequence":"additional","affiliation":[{"name":"Internal Medicine Division, Soroka University Medical Center, Ben-Gurion University of the Negev, Beer-Sheva, Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Iftach","family":"Sagy","sequence":"additional","affiliation":[{"name":"Internal Medicine Division, Soroka University Medical Center, Ben-Gurion University of the Negev, Beer-Sheva, Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gal","family":"Tsaban","sequence":"additional","affiliation":[{"name":"Internal Medicine Division, Soroka University Medical Center, Ben-Gurion University of the Negev, Beer-Sheva, Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Merav","family":"Cohen-Lahav","sequence":"additional","affiliation":[{"name":"Division of Biochemistry Laboratory, Soroka University Medical Center, Ben-Gurion University of the Negev, Beer-Sheva, Israel."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gil","family":"Goldinger","sequence":"additional","affiliation":[{"name":"Internal Medicine Division, Soroka University Medical Center, Ben-Gurion University of the Negev, Beer-Sheva, Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michal","family":"Peled","sequence":"additional","affiliation":[{"name":"Internal Medicine Division, Soroka University Medical Center, Ben-Gurion University of the Negev, Beer-Sheva, Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carmi","family":"Bartal","sequence":"additional","affiliation":[{"name":"Internal Medicine Division, Soroka University Medical Center, Ben-Gurion University of the Negev, Beer-Sheva, Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,7,15]]},"reference":[{"key":"R1-20250504","doi-asserted-by":"crossref","first-page":"566","DOI":"10.1016\/S0099-1767(96)80213-3","article-title":"A comparison of hemolysis rates using intravenous catheters versus venipuncture tubes for obtaining blood samples.","volume":"22","author":"Kennedy","year":"1996","journal-title":"J Emerg Nurs"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"193","DOI":"10.11613\/BM.2013.022","article-title":"Critical review and meta-analysis of spurious hemolysis in blood samples collected from intravenous catheters.","volume":"23","author":"Lippi","year":"2013","journal-title":"Biochem Med (Zagreb)"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.jen.2007.02.006","article-title":"Nursing blood specimen collection techniques and hemolysis rates in an emergency department: analysis of venipuncture versus intravenous catheter collection techniques.","volume":"34","author":"Lowe","year":"2008","journal-title":"J Emerg Nurs"},{"key":"R4-20250504","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1309\/LM2XCV5SQML1ONTM","article-title":"Blood collection from intravenous lines: is one drawing site better than others?","volume":"45","author":"Lippi","year":"2014","journal-title":"Lab Med"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1067\/men.2003.66","article-title":"The effect of blood drawing techniques and equipment on the hemolysis of ED laboratory blood samples.","volume":"29","author":"Grant","year":"2003","journal-title":"J Emerg Nurs"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"1142","DOI":"10.1016\/j.clinbiochem.2013.04.005","article-title":"Low vacuum and discard tubes reduce hemolysis in samples drawn from intravenous catheters.","volume":"46","author":"Heiligers-Duckers","year":"2013","journal-title":"Clin Biochem"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1016\/S0196-0644(05)81705-6","article-title":"Intravenous catheter aspiration for obtaining basic analytes during intravenous infusion.","volume":"19","author":"Herr","year":"1990","journal-title":"Ann Emerg Med"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"e004250","DOI":"10.1136\/bmjopen-2013-004250","article-title":"A cross-sectional study to compare two blood collection methods: direct venous puncture and peripheral venous catheter.","volume":"4","author":"Ortells-Abuye","year":"2014","journal-title":"BMJ Open"},{"key":"R9-20250504","doi-asserted-by":"crossref","first-page":"93","DOI":"10.5539\/gjhs.v8n7p93","article-title":"Blood samples of peripheral venous catheter or the usual way: do infusion fluid alters the biochemical test results?","volume":"8","author":"Taghizadeganzadeh","year":"2015","journal-title":"Glob J Health Sci"},{"key":"R10-20250504","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1197\/j.aem.2006.06.053","article-title":"Comparison of laboratory values obtained by phlebotomy versus saline lock devices.","volume":"14","author":"Corbo","year":"2007","journal-title":"Acad Emerg Med"},{"key":"R11-20250504","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/j.jen.2012.03.014","article-title":"Venipuncture versus peripheral catheter: do infusions alter laboratory results?","volume":"40","author":"Hambleton","year":"2014","journal-title":"J Emerg Nurs"},{"key":"R12-20250504","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1067\/mem.2001.118015","article-title":"Comparison of laboratory values obtained by means of routine venipuncture versus peripheral intravenous catheter after a normal saline solution bolus.","volume":"38","author":"Zlotowski","year":"2001","journal-title":"Ann Emerg Med"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"250","DOI":"10.4037\/ajcc1999.8.4.250","article-title":"Obtaining blood samples for coagulation studies from a normal saline lock.","volume":"8","author":"Powers","year":"1999","journal-title":"Am J Crit Care"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1111\/j.1365-2702.2006.01858.x","article-title":"Comparison of two blood sampling methods in anticoagulation therapy: venipuncture and peripheral venous catheter.","volume":"17","author":"Zengin","year":"2008","journal-title":"J Clin Nurs"},{"key":"R15-20250504","doi-asserted-by":"crossref","first-page":"e179","DOI":"10.1542\/peds.2009-2920","article-title":"Blood sampling through peripheral venous catheters is reliable for selected basic analytes in children.","volume":"126","author":"Berger-Achituv","year":"2010","journal-title":"Pediatrics"},{"key":"R16-20250504","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1177\/2054270419894817","article-title":"\u201cBlood sampled from existing peripheral IV cannulae yields results equivalent to venepuncture: a systematic review.\u201d","volume":"11","author":"Lesser","year":"2020","journal-title":"JRSM open"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000029268","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T04:13:45Z","timestamp":1746332025000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000029268"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,15]]},"references-count":16,"journal-issue":{"issue":"28","published-online":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000029268","relation":{},"ISSN":["1536-5964"],"issn-type":[{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,15]]}}}