{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T10:57:26Z","timestamp":1761649046336,"version":"3.40.5"},"reference-count":36,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"29","license":[{"start":{"date-parts":[[2022,7,22]],"date-time":"2022-07-22T00:00:00Z","timestamp":1658448000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>Multilevel cervical corpectomy has raised the concern among surgeons that reconstruction with the anterior cervical screw plate system (ACSPS) alone may fail eventually. As an alternative, the anterior cervical transpedicular screw (ACTPS) has been adopted in clinical practice. We used the finite element analysis to investigate whether ACTPS is a more reasonable choice, in comparison with ACSPS, after a 2-level corpectomy in the subaxial cervical spine. These 2 types of implantation models with the applied 75\u2009N axial pressure and 1\u2009N \u2022 m pure moment of the couple were evaluated. Compared with the intact model, the range of motion (ROM) at the operative segments (C4\u2013C7) decreased by 97.5% in flexion-extension, 91.3% in axial rotation, and 99.3% in lateral bending in the ACTPS model, whereas it decreased by 95.1%, 73.4%, 96.9% in the ACSPS model respectively. The ROM at the adjacent segment (C3\/4) in the ACTPS model decreased in all motions, while that of the ACSPS model increased in axial rotation and flexion-extension compared with the intact model. Compared to the ACSPS model, whose stress concentrated on the interface between the screws and the titanium plate, the stress of the ACTPS model was well-distributed. There was also a significant difference between the maximum stress value of the 2 models. ACTPS and ACSPS are biomechanically favorable. The stability in reducing ROM of ACTPS may be better and the risk of failure for internal fixator is relatively low compared with ACSPS fixation except for under lateral bending in reconstruction the stability of the subaxial cervical spine after 2-level corpectomy.<\/jats:p>","DOI":"10.1097\/md.0000000000029316","type":"journal-article","created":{"date-parts":[[2022,7,22]],"date-time":"2022-07-22T14:04:18Z","timestamp":1658498658000},"page":"e29316","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["Anterior cervical transpedicular screw fixation system in subaxial cervical spine: A finite element comparative study"],"prefix":"10.1097","volume":"101","author":[{"given":"Jie","family":"Li","sequence":"first","affiliation":[{"name":"Department of Orthopedics surgery, Ningbo Medical Center Li Huili Hospital, Affiliated to Ningbo University, Ningbo 315040, Zhejiang, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kaifeng","family":"Gan","sequence":"additional","affiliation":[{"name":"Department of Orthopedics surgery, Ningbo Medical Center Li Huili Hospital, Affiliated to Ningbo University, Ningbo 315040, Zhejiang, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Binhui","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Orthopedics surgery, Ningbo Medical Center Li Huili Hospital, Affiliated to Ningbo University, Ningbo 315040, Zhejiang, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yilei","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou 310016, Zhejiang, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jinjiong","family":"Hong","sequence":"additional","affiliation":[{"name":"Department of spinal surgery, Ningbo 6th hospital, Ningbo 315040, zhejiang, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dikai","family":"Bei","sequence":"additional","affiliation":[{"name":"Department of Orthopedics surgery, Ningbo Medical Center Li Huili Hospital, Affiliated to Ningbo University, Ningbo 315040, Zhejiang, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tengdi","family":"Fan","sequence":"additional","affiliation":[{"name":"Department of Orthopedics surgery, Ningbo Medical Center Li Huili Hospital, Affiliated to Ningbo University, Ningbo 315040, Zhejiang, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Minzhe","family":"Zheng","sequence":"additional","affiliation":[{"name":"Department of Orthopedics surgery, Ningbo Medical Center Li Huili Hospital, Affiliated to Ningbo University, Ningbo 315040, Zhejiang, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Liujun","family":"Zhao","sequence":"additional","affiliation":[{"name":"Department of spinal surgery, Ningbo 6th hospital, Ningbo 315040, zhejiang, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2945-8707","authenticated-orcid":false,"given":"Fengdong","family":"Zhao","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou 310016, Zhejiang, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2022,7,22]]},"reference":[{"key":"R1-20250504","doi-asserted-by":"crossref","first-page":"607","DOI":"10.2106\/00004623-195840030-00009","article-title":"The treatment of certain cervical-spine disorders by anterior removal of the intervertebral disc and interbody fusion","volume":"40-A","author":"Smith","year":"1958","journal-title":"J Bone Joint Surg Am"},{"issue":"22 Suppl 1","key":"R2-20250504","doi-asserted-by":"crossref","first-page":"S173","DOI":"10.1097\/BRS.0b013e3182a7eaaf","article-title":"Anterior versus posterior approach for treatment of cervical spondylotic myelopathy: a systematic review","volume":"38","author":"Lawrence","year":"2013","journal-title":"Spine"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"1974","DOI":"10.1097\/00007632-199310001-00009","article-title":"Anterior cervical discectomy, fusion, and plating. A comparative animal study","volume":"18","author":"Zdeblick","year":"1993","journal-title":"Spine"},{"key":"R4-20250504","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1097\/01.brs.0000250304.24001.24","article-title":"Comparison of multisegment anterior cervical fixation using bone strut graft versus a titanium rod and buttress prosthesis: analysis of outcome with long-term follow-up and interview by independent physician","volume":"32","author":"Brazenor","year":"2007","journal-title":"Spine"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1097\/BSD.0b013e3180654205","article-title":"Long-term biomechanical stability and clinical improvement after extended multilevel corpectomy and circumferential reconstruction of the cervical spine using titanium mesh cages","volume":"21","author":"Acosta","year":"2008","journal-title":"J Spinal Disord Tech"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"2055","DOI":"10.1007\/s00586-007-0398-7","article-title":"4- and 5-level anterior fusions of the cervical spine: review of literature and clinical results","volume":"16","author":"Koller","year":"2007","journal-title":"Eur Spine J"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"1300","DOI":"10.1007\/s00586-009-1054-1","article-title":"In vitro study of accuracy of cervical pedicle screw insertion using an electronic conductivity device (ATPS part III)","volume":"18","author":"Koller","year":"2009","journal-title":"Eur Spine J"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1007\/s00586-007-0572-y","article-title":"Cervical anterior transpedicular screw fixation. Part I: Study on morphological feasibility, indications, and technical prerequisites","volume":"17","author":"Koller","year":"2008","journal-title":"Eur Spine J"},{"key":"R9-20250504","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1007\/s00586-007-0573-x","article-title":"Cervical anterior transpedicular screw fixation (ATPS)--Part II. Accuracy of manual insertion and pull-out strength of ATPS","volume":"17","author":"Koller","year":"2008","journal-title":"Euro Spine J"},{"key":"R10-20250504","first-page":"1337","article-title":"The study of anterior cervical pedicle screw channel in the lower cervical spine","volume":"31","author":"Xu","year":"2011","journal-title":"Chin J Orthop"},{"key":"R11-20250504","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1111\/j.1757-7861.2011.00145.x","article-title":"A new technique for anterior cervical pedicle screw implantation","volume":"3","author":"Zhao","year":"2011","journal-title":"Orthop Surg"},{"key":"R12-20250504","doi-asserted-by":"crossref","first-page":"911","DOI":"10.1007\/s00586-009-0949-1","article-title":"Anterior cervical pedicle screw and plate fixation using fluoroscope-assisted pedicle axis view imaging: a preliminary report of a new cervical reconstruction technique","volume":"18","author":"Yukawa","year":"2009","journal-title":"Eur Spine J"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1007\/s00701-008-1574-1","article-title":"Anterior pedicle screw fixation for multilevel cervical corpectomy and spinal fusion.","volume":"150","author":"Aramomi","year":"2008","journal-title":"Acta neurochirurgica"},{"key":"R15-20250504","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1115\/1.3138670","article-title":"A three-dimensional nonlinear finite element model of lumbar intervertebral joint in torsion","volume":"109","author":"Ueno","year":"1987","journal-title":"J Biomech Eng"},{"key":"R16-20250504","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1097\/00007632-198403000-00003","article-title":"Stress analysis of the lumbar disc-body unit in compression. A three-dimensional nonlinear finite element study","volume":"9","author":"Shirazi-Adl","year":"1984","journal-title":"Spine"},{"key":"R17-20250504","doi-asserted-by":"crossref","first-page":"887","DOI":"10.1097\/00007632-199504150-00003","article-title":"Role of ligaments and facets in lumbar spinal stability","volume":"20","author":"Sharma","year":"1995","journal-title":"Spine"},{"key":"R18-20250504","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1097\/00007632-199105000-00002","article-title":"Analysis and prevention of spinal column deformity following cervical laminectomy. I. Pathogenetic analysis of postlaminectomy deformities","volume":"16","author":"Saito","year":"1991","journal-title":"Spine"},{"key":"R19-20250504","doi-asserted-by":"crossref","first-page":"E7","DOI":"10.3171\/foc.2004.17.3.7","article-title":"In vitro biomechanics of cervical disc arthroplasty with the ProDisc-C total disc implant","volume":"17","author":"DiAngelo","year":"2004","journal-title":"Neurosurg Focus"},{"key":"R20-20250504","doi-asserted-by":"crossref","first-page":"1737","DOI":"10.1097\/01.BRS.0000134574.36487.EB","article-title":"Biomechanical effects of C2-C7 intersegmental stability due to laminectomy with unilateral and bilateral facetectomy.","volume":"29","author":"Hong-Wan","year":"2004","journal-title":"Spine"},{"key":"R21-20250504","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1115\/1.1322034","article-title":"Geometric and mechanical properties of human cervical spine ligaments","volume":"122","author":"Yoganandan","year":"2000","journal-title":"J Biomech Eng"},{"key":"R22-20250504","doi-asserted-by":"crossref","first-page":"1458","DOI":"10.1007\/s10439-008-9534-8","article-title":"Validation of a finite element model of the young normal lower cervical spine","volume":"36","author":"Wheeldon","year":"2008","journal-title":"Ann Biomed Eng"},{"key":"R23-20250504","doi-asserted-by":"crossref","first-page":"726","DOI":"10.1097\/00007632-198807000-00003","article-title":"Three-dimensional movements of the upper cervical spine","volume":"13","author":"Panjabi","year":"1988","journal-title":"Spine"},{"key":"R24-20250504","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1002\/jor.1100150305","article-title":"Uncinate processes and Luschka joints influence the biomechanics of the cervical spine: quantification using a finite element model of the C5-C6 segment","volume":"15","author":"Clausen","year":"1997","journal-title":"J Orthop Res"},{"key":"R25-20250504","doi-asserted-by":"crossref","first-page":"2692","DOI":"10.1097\/00007632-200112150-00012","article-title":"Mechanical properties of the human cervical spine as shown by three-dimensional load-displacement curves","volume":"26","author":"Panjabi","year":"2001","journal-title":"Spine"},{"key":"R26-20250504","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1016\/0021-9290(88)90285-0","article-title":"Load-displacement properties of lower cervical spine motion segments","volume":"21","author":"Moroney","year":"1988","journal-title":"J Biomech"},{"key":"R27-20250504","doi-asserted-by":"crossref","first-page":"1520","DOI":"10.1007\/s00586-009-1085-7","article-title":"Local and global subaxial cervical spine biomechanics after single-level fusion or cervical arthroplasty","volume":"18","author":"Finn","year":"2009","journal-title":"Eur Spine J"},{"key":"R28-20250504","doi-asserted-by":"crossref","first-page":"2637","DOI":"10.1097\/00007632-199412000-00007","article-title":"Vertebral artery location in relation to the vertebral body as determined by two-dimensional computed tomography evaluation","volume":"19","author":"Vaccaro","year":"1994","journal-title":"Spine"},{"key":"R29-20250504","doi-asserted-by":"crossref","first-page":"2040","DOI":"10.1097\/00007632-200008150-00007","article-title":"Three- and four-level anterior cervical discectomy and fusion with plate fixation: a prospective study","volume":"25","author":"Bolesta","year":"2000","journal-title":"Spine"},{"key":"R30-20250504","doi-asserted-by":"crossref","first-page":"1402","DOI":"10.1097\/01.brs.0000166526.78058.3c","article-title":"Early failures following cervical corpectomy reconstruction with titanium mesh cages and anterior plating","volume":"30","author":"Daubs","year":"2005","journal-title":"Spine"},{"key":"R31-20250504","doi-asserted-by":"crossref","first-page":"1551","DOI":"10.1007\/s00586-012-2296-x","article-title":"Efficacy of multilevel anterior cervical discectomy and fusion versus corpectomy and fusion for multilevel cervical spondylotic myelopathy: a minimum 5-year follow-up study","volume":"21","author":"Song","year":"2012","journal-title":"Eur Spine J"},{"key":"R32-20250504","doi-asserted-by":"crossref","first-page":"172","DOI":"10.3171\/2011.10.SPINE11116","article-title":"Adjacent-level biomechanics after single versus multilevel cervical spine fusion","volume":"16","author":"Prasarn","year":"2012","journal-title":"J neurosurg Spine"},{"key":"R33-20250504","doi-asserted-by":"crossref","first-page":"1016","DOI":"10.1097\/01.BRS.0000061998.62204.D7","article-title":"Graft migration or displacement after multilevel cervical corpectomy and strut grafting.","volume":"28","author":"Wang","year":"2003","journal-title":"Spine"},{"key":"R34-20250504","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1055\/s-0028-1082061","article-title":"Analysis of reoperations after surgical treatment of degenerative cervical spine disorders: a report on 900 cases","volume":"70","author":"Greiner-Perth","year":"2009","journal-title":"Cent Eur neurosurg"},{"key":"R35-20250504","doi-asserted-by":"crossref","first-page":"2137","DOI":"10.1007\/s00586-010-1503-x","article-title":"The stabilizing potential of anterior, posterior and combined techniques for the reconstruction of a 2-level cervical corpectomy model: biomechanical study and first results of ATPS prototyping","volume":"19","author":"Koller","year":"2010","journal-title":"Eur Spine J"},{"key":"R36-20250504","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1007\/978-3-319-01830-0_1","article-title":"Navigation, robotics, and intraoperative imaging in spinal surgery","volume":"41","author":"Ringel","year":"2014","journal-title":"Adv Tech Stand Neurosurg"},{"key":"R37-20250504","doi-asserted-by":"crossref","first-page":"e53580","DOI":"10.1371\/journal.pone.0053580","article-title":"Construction and accuracy assessment of patient-specific biocompatible drill template for cervical anterior transpedicular screw (ATPS) insertion: an in vitro study","volume":"8","author":"Fu","year":"2013","journal-title":"PLoS One"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000029316","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T04:21:00Z","timestamp":1746332460000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000029316"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,22]]},"references-count":36,"journal-issue":{"issue":"29","published-online":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000029316","relation":{},"ISSN":["1536-5964"],"issn-type":[{"type":"electronic","value":"1536-5964"}],"subject":[],"published":{"date-parts":[[2022,7,22]]}}}