{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,12]],"date-time":"2026-11-12T19:56:00Z","timestamp":1794513360964,"version":"4.9.1"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"30","license":[{"start":{"date-parts":[[2022,7,29]],"date-time":"2022-07-29T00:00:00Z","timestamp":1659052800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>The risk of displaced and comminuted midshaft clavicle fractures is increased in high-energy traumas such as sport injuries and traffic accidents. Open reduction and plate fixation have been widely used for midshaft clavicle fractures. Among various plates for clavicle shaft fractures, superior locking compression plates (LCPs) have been mostly used. In plate fixation, nonunion caused by implant failure is the most difficult complication. The most common reasons for metal plate failure are excessive stress and stress concentration caused by cantilever bending. These causes were easily addressed using a locking screw cap (LSC).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>The clavicle 3-dimensional image was made from a computed tomography scan, and the clavicle midshaft fracture model was generated with a 10-mm interval. The fracture model was fixed with a superior LCP, and finite element analysis was conducted between the presence (<jats:italic toggle=\"yes\">with LSC model<\/jats:italic>) and absence (<jats:italic toggle=\"yes\">without LSC model<\/jats:italic>) of an LSC on the site of the fracture. The stresses of screw holes in models with and without LSCs were measured under 3 forces: 100\u2009N cantilever bending force, 100\u2009N axial compression force, and 1 N\u00b7m axial torsion force. After the finite element analysis, a validation test was conducted on the cantilever bending force known as the greatest force applied to superior locking plates.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The mean greatest stress under the cantilever bending force was significantly greater than other loading forces. The highest stress site was the screw hole edge on the fracture site in both models under the cantilever bending and axial compression forces. Under the axial torsional force, the maximum stress point was the lateral first screw hole edge. The ultimate plate stress of the <jats:italic toggle=\"yes\">with LSC model<\/jats:italic> is completely lower than that of the <jats:italic toggle=\"yes\">without LSC model<\/jats:italic>. According to the validation test, the stiffness, ultimate load, and yield load of the <jats:italic toggle=\"yes\">with LSC model<\/jats:italic> were higher than those of the <jats:italic toggle=\"yes\">without LSC model<\/jats:italic>.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Therefore, inserting an LSC into an empty screw hole in the fracture area reduces the maximum stress on an LCP and improves biomechanical stability.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000029319","type":"journal-article","created":{"date-parts":[[2022,8,10]],"date-time":"2022-08-10T22:02:37Z","timestamp":1660168957000},"page":"e29319","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":7,"title":["Numerical simulation and biomechanical analysis of locking screw caps on clavicle locking plates"],"prefix":"10.1097","volume":"101","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6355-4105","authenticated-orcid":false,"given":"Dae-Geun","family":"Kim","sequence":"first","affiliation":[{"name":"Department of Orthopedic Surgery, College of Medicine, Soonchunhyang University Gumi Hospital, Gumi, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Soo","family":"Min Kim","sequence":"additional","affiliation":[{"name":"Convergence Material Research Center, Innovative Technology Research Division, Gumi Electronics & Information Technology Research Institute (GERI), Gumi, Republic of Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoonkap","family":"Kim","sequence":"additional","affiliation":[{"name":"Convergence Material Research Center, Innovative Technology Research Division, Gumi Electronics & Information Technology Research Institute (GERI), Gumi, Republic of Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,7,29]]},"reference":[{"key":"R1-20250504","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1097\/00003086-199403000-00016","article-title":"The incidence of fractures of the clavicle.","volume":"300","author":"Nordqvist","year":"1994","journal-title":"Clin Orthop Relat Res"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1302\/0301-620X.80B3.0800476","article-title":"Fractures of the clavicle in the adult. Epidemiology and classification.","volume":"80","author":"Robinson","year":"1998","journal-title":"J Bone Joint Surg Br"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1067\/mse.2002.126613","article-title":"Epidemiology of clavicle fractures.","volume":"11","author":"Postacchini","year":"2002","journal-title":"J Shoulder Elbow Surg"},{"key":"R4-20250504","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1097\/00003086-196805000-00006","article-title":"An atlas of anatomy and treatment of midclavicular fractures.","volume":"58","author":"Rowe","year":"1968","journal-title":"Clin Orthop Relat Res"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/j.jse.2005.08.007","article-title":"Conservative treatment of fractures at the middle third of the clavicle: the relevance of shortening and clinical outcome.","volume":"15","author":"Lazarides","year":"2006","journal-title":"J Shoulder Elbow Surg"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1016\/j.jse.2011.08.053","article-title":"Treatment of clavicle fractures: current concepts review.","volume":"21","author":"van der Meijden","year":"2012","journal-title":"J Shoulder Elbow Surg"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1097\/CORR.0000000000000986","article-title":"What is the best evidence for management of displaced midshaft clavicle fractures? A systematic review and network meta-analysis of 22 randomized controlled trials.","volume":"478","author":"Axelrod","year":"2020","journal-title":"Clin Orthop Relat Res"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"e543","DOI":"10.3928\/01477447-20140528-54","article-title":"Operative versus non-operative treatment in complex proximal humeral fractures: a meta-analysis of randomized controlled trials.","volume":"37","author":"Jia","year":"2014","journal-title":"Orthopedics"},{"key":"R9-20250504","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1097\/01.bot.0000172287.44278.ef","article-title":"Treatment of acute midshaft clavicle fractures: systematic review of 2144 fractures: on behalf of the evidence-based orthopaedic trauma working group.","volume":"19","author":"Zlowodzki","year":"2005","journal-title":"J Orthop Trauma"},{"key":"R10-20250504","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1097\/BOT.0000000000000936","article-title":"Midshaft fractures of the clavicle: a meta-analysis comparing surgical fixation using anteroinferior plating versus superior plating.","volume":"31","author":"Nourian","year":"2017","journal-title":"J Orthop Trauma"},{"key":"R11-20250504","doi-asserted-by":"crossref","first-page":"1051","DOI":"10.2106\/JBJS.16.01068","article-title":"Plate fixation versus nonoperative treatment for displaced midshaft clavicular fractures: a meta-analysis of randomized controlled trials.","volume":"99","author":"Woltz","year":"2017","journal-title":"J Bone Joint Surg Am"},{"key":"R12-20250504","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1186\/s13018-019-1259-x","article-title":"Comparison of implant failure rates of different plates for midshaft clavicular fractures based on fracture classifications.","volume":"14","author":"Chiu","year":"2019","journal-title":"J Orthop Surg Res"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1067\/mse.2002.125805","article-title":"Effects of plate location and selection on the stability of midshaft clavicle osteotomies: a biomechanical study.","volume":"11","author":"Iannotti","year":"2002","journal-title":"J Shoulder Elbow Surg"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1016\/j.injury.2017.01.040","article-title":"Construct failure after open reduction and plate fixation of displaced midshaft clavicular fractures.","volume":"48","author":"Meeuwis","year":"2017","journal-title":"Injury"},{"key":"R15-20250504","doi-asserted-by":"crossref","first-page":"759","DOI":"10.1007\/s11517-015-1288-5","article-title":"Strength analysis of clavicle fracture fixation devices and fixation techniques using finite element analysis with musculoskeletal force input.","volume":"53","author":"Marie","year":"2015","journal-title":"Med Biol Eng Comput"},{"key":"R16-20250504","first-page":"308","article-title":"Clavicle nonunion and plate breakage after locking compression plate fixation of displaced midshaft clavicular fractures.","volume":"19","author":"Huang","year":"2020","journal-title":"Exp Ther Med"},{"key":"R17-20250504","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1186\/s12891-019-2847-y","article-title":"Finite element analysis comparison between superior clavicle locking plate with and without screw holes above fracture zone in midshaft clavicular fracture.","volume":"20","author":"Pengrung","year":"2019","journal-title":"BMC Musculoskelet Disord"},{"key":"R18-20250504","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1016\/j.medengphy.2016.06.021","article-title":"Conceptual finite element study for comparison among superior, anterior, and spiral clavicle plate fixations for midshaft clavicle fracture.","volume":"38","author":"Huang","year":"2016","journal-title":"Med Eng Phys"},{"key":"R19-20250504","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1016\/j.jseint.2020.01.010","article-title":"An evaluation of treatment options for medial, midshaft, and distal clavicle fractures: a systematic review and meta-analysis.","volume":"4","author":"Vannabouathong","year":"2020","journal-title":"JSES Int"},{"key":"R20-20250504","first-page":"1","article-title":"Finite element analysis of dual small plate fixation and single plate fixation for treatment of midshaft clavicle fractures.","volume":"15","author":"Zhang","year":"2020","journal-title":"J Orthop Surg Res"},{"key":"R21-20250504","doi-asserted-by":"crossref","first-page":"e16898","DOI":"10.1097\/MD.0000000000016898","article-title":"Finite element analysis of spiral plate and Herbert screw fixation for treatment of midshaft clavicle fractures.","volume":"98","author":"Zhang","year":"2019","journal-title":"Medicine (Baltimore)"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000029319","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T04:12:59Z","timestamp":1746331979000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000029319"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,29]]},"references-count":21,"journal-issue":{"issue":"30","published-online":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000029319","relation":{},"ISSN":["1536-5964"],"issn-type":[{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,29]]}}}