{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T23:42:40Z","timestamp":1787010160705,"version":"build-2736575974"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"28","license":[{"start":{"date-parts":[[2022,7,15]],"date-time":"2022-07-15T00:00:00Z","timestamp":1657843200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>The optimal treatment strategy for femoral neck fractures remained controversial, especially the Pauwels type III femoral neck fracture of young patients was a challenge. Femoral neck system (FNS) was a newly developed internal fixation for treating femoral neck fracture and this study aimed to compare the biomechanical advantages and disadvantages between FNS and 3 cannulated configuration screws (CCS) with or without an additional medial buttress plate (MBP).<\/jats:p>\n                  <jats:p>In this study, Pauwels type III femoral neck fracture model with an angle of 70\u00b0 was constructed and 3 different fixation models, FNS, CCS + MBP, CCS alone, were developed. A vertical force of 2100N was applied on the femoral head, then the maximum von Mises stress of whole model, distal femur, femoral head, and internal fixation was recorded, as well as the stress distribution of whole model, proximal fracture section, and internal fixation of the 3 models. Moreover, the maximum displacement of the whole model, distal femur, femoral head, internal fixation, and the relative displacement of the proximal and distal portion was also compared.<\/jats:p>\n                  <jats:p>The maximum von Mises stress value was 318.302\u2009MPa in FNS, 485.226\u2009MPa in CCS + 1\/3 plate, and 425.889\u2009MPa in CCS. The FNS showed lowest maximum von Mises stress values in distal part, femoral head, and internal implant. All fixation configurations were observed stress concentrated at the posteroinferior area of cross-section of femoral head and at the fracture section area of implant; however, FNS had more uniform stress distribution. For displacement, the maximum displacement value was 8.5446\u2009mm in FNS, 8.2863\u2009mm in CCS + 1\/3 plate, and 8.3590\u2009mm in CCS. However, FNS had higher maximum displacement in femoral head and internal implant, but lower maximum displacement in the distal part of fracture model. The FNS represented a significantly higher relative displacement between the femoral head and distal femur when compared with the other 2 fixation configurations.<\/jats:p>\n                  <jats:p>The newly developed FNS could achieve the dual effect of angular stability and sliding compression for the treatment of Pauwels type III femoral neck fractures, which provided superior biomechanical stability than CCS alone and CCS with additional MBP.<\/jats:p>","DOI":"10.1097\/md.0000000000029450","type":"journal-article","created":{"date-parts":[[2022,9,8]],"date-time":"2022-09-08T11:05:26Z","timestamp":1662635126000},"page":"e29450","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":40,"title":["Finite element analysis of femoral neck system in the treatment of Pauwels type III femoral neck fracture"],"prefix":"10.1097","volume":"101","author":[{"given":"Yanbin","family":"Teng","sequence":"first","affiliation":[{"name":"Yanbin Teng, Department of Orthopedics and Trauma Weifang People\u2019s Hospital, Shandong province, People\u2019s Republic of China, Yan Zhang, Department of Nephrology, Weifang People\u2019s Hospital, Shandong province, People\u2019s Republic of China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Zhang","sequence":"additional","affiliation":[{"name":"Yanbin Teng, Department of Orthopedics and Trauma Weifang People\u2019s Hospital, Shandong province, People\u2019s Republic of China, Yan Zhang, Department of Nephrology, Weifang People\u2019s Hospital, Shandong province, People\u2019s Republic of China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7401-6716","authenticated-orcid":false,"given":"Chaowei","family":"Guo","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Luoyang Orthopedic Hospital of Henan Province, Henan Province, People\u2019s Republic of China."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,7,15]]},"reference":[{"key":"R1-20250504","first-page":"618","article-title":"The management of intracapsular fractures of the proximal femur","volume":"83","author":"Parker","year":"2000","journal-title":"Bone Joint J"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"1889","DOI":"10.1016\/j.injury.2019.07.020","article-title":"Biomechanical properties of off-axis screw in Pauwels III femoral neck fracture fixation: bicortical screw construct is superior to unicortical screw construct","volume":"50","author":"Kuan","year":"2019","journal-title":"Injury"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"1895","DOI":"10.1016\/j.injury.2019.08.024","article-title":"Medial anatomical buttress plate in treating displaced femoral neck fracture a finite element analysis","volume":"50","author":"Li","year":"2019","journal-title":"Injury"},{"key":"R4-20250504","doi-asserted-by":"crossref","first-page":"2189","DOI":"10.1016\/j.injury.2017.08.017","article-title":"Medial buttress plate augmentation of cannulated screw fixation in vertically unstable femoral neck fractures: surgical technique and preliminary results","volume":"48","author":"Ye","year":"2017","journal-title":"Injury"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"1837","DOI":"10.1016\/j.injury.2017.06.013","article-title":"Femoral neck shortening in adult patients under the age of 55 years is associated with worse functional outcomes: analysis of the prospective multi-center study of hip fracture outcomes in China (SHOC)","volume":"48","author":"Slobogean","year":"2017","journal-title":"Injury"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1097\/BLO.0b013e31805b7ec4","article-title":"Shortening after femoral neck fracture fixation: is there a solution?","volume":"461","author":"Zlowodzki","year":"2007","journal-title":"Clin Orthop Relat Res"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"484","DOI":"10.1016\/j.injury.2014.10.010","article-title":"Complications following young femoral neck fractures","volume":"46","author":"Slobogean","year":"2015","journal-title":"Injury"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1097\/01.blo.0000188557.65387.fc","article-title":"Does screw configuration affect subtrochanteric fracture after femoral neck fixation?","volume":"443","author":"Oakey","year":"2006","journal-title":"Clin Orthop Relat Res"},{"key":"R9-20250504","doi-asserted-by":"crossref","first-page":"61","DOI":"10.2106\/JBJS.K.01081","article-title":"Risk factors for nonunion in patients with intracapsular femoral neck fractures treated with three cannulated screws placed in either a triangle or an inverted triangle configuration","volume":"95","author":"Yang","year":"2013","journal-title":"J Bone Joint Surg Am"},{"key":"R10-20250504","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1016\/j.mehy.2015.01.029","article-title":"Application of a medial buttress plate may prevent many treatment failures seen after fixation of vertical femoral neck fractures in young adults","volume":"84","author":"Mir","year":"2015","journal-title":"Med Hypotheses"},{"key":"R11-20250504","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1097\/BTO.0000000000000131","article-title":"Displaced femoral neck fracture in young adults: accessory fixation with buttress plating","volume":"30","author":"Collinge","year":"2015","journal-title":"Tech Orthop"},{"key":"R12-20250504","first-page":"88","article-title":"Higher stability and more predictive fixation with the femoral neck system versus Hansson pins in femoral neck fractures Pauwels II","volume":"24","author":"Schopper","year":"2020","journal-title":"J Orthop Transl"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1097\/BOT.0000000000000739","article-title":"Biomechanical evaluation of the femoral neck system in unstable Pauwels III femoral neck fractures: a comparison with the dynamic hip screw and cannulated screws","volume":"31","author":"Stoffel","year":"2017","journal-title":"J Orthop Trauma"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"1969","DOI":"10.1016\/j.injury.2015.06.016","article-title":"Using a modified Pauwels method to predict the outcome of femoral neck fracture in relatively young patients","volume":"46","author":"Wang","year":"2015","journal-title":"Injury"},{"key":"R15-20250504","doi-asserted-by":"crossref","first-page":"1271762","DOI":"10.1155\/2018\/1271762","article-title":"Optimum configuration of cannulated compression screws for the fixation of unstable femoral neck fractures: finite element analysis evaluation","volume":"2018","author":"Li","year":"2018","journal-title":"Biomed Res Int"},{"key":"R16-20250504","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1097\/BOT.0000000000001377","article-title":"Vascular anatomy of the medial femoral neck and implications for surface plate fixation","volume":"33","author":"Putnam","year":"2019","journal-title":"J Orthop Trauma"},{"key":"R17-20250504","doi-asserted-by":"crossref","first-page":"e21","DOI":"10.2106\/JBJS.CC.18.00135","article-title":"Femoral neck fracture fixation with a medial buttress plate that led to impingement with hip flexion","volume":"9","author":"Marchand","year":"2019","journal-title":"JBJS Case Connect"},{"key":"R18-20250504","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1007\/s00068-016-0659-4","article-title":"Low failure rate by means of DLBP fixation of undisplaced femoral neck fractures","volume":"43","author":"van Walsum","year":"2017","journal-title":"Eur J Trauma Emerg Surg"},{"key":"R19-20250504","doi-asserted-by":"crossref","first-page":"2495","DOI":"10.1016\/j.injury.2016.09.013","article-title":"Three-year outcomes of intracapsular femoral neck fractures fixed with sliding hip screws in adults aged under sixty-five years","volume":"47","author":"Dargan","year":"2016","journal-title":"Injury"},{"key":"R20-20250504","doi-asserted-by":"crossref","first-page":"1802","DOI":"10.1111\/os.13098","article-title":"Comparison of early clinical results for femoral neck system and cannulated screws in the treatment of unstable femoral neck fractures","volume":"13","author":"Zhou","year":"2021","journal-title":"Orthop Surg"},{"key":"R21-20250504","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1186\/s13018-021-02659-0","article-title":"Femoral neck system versus inverted cannulated cancellous screw for the treatment of femoral neck fractures in adults: a preliminary comparative study","volume":"16","author":"Tang","year":"2021","journal-title":"J Orthop Surg Res"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000029450","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T00:13:32Z","timestamp":1746317612000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000029450"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,15]]},"references-count":21,"journal-issue":{"issue":"28","published-online":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000029450","relation":{},"ISSN":["1536-5964"],"issn-type":[{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,15]]}}}