{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T06:37:15Z","timestamp":1780468635096,"version":"3.54.1"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"36","license":[{"start":{"date-parts":[[2022,9,9]],"date-time":"2022-09-09T00:00:00Z","timestamp":1662681600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,9,9]]},"abstract":"<jats:p>Myocardial computed tomography perfusion (CTP) imaging is a noninvasive method for detecting myocardial ischemia. This study aimed to compare the diagnostic performance of dynamic and static adenosine-stress CTPs for detecting hemodynamically significant coronary stenosis. We prospectively enrolled 42 patients (mean age, 59.7 \u00b1 8.8 years; 31 males) with \u226540% coronary artery stenosis. All patients underwent dynamic CTP for adenosine stress. The static CTP was simulated by choosing the seventh dynamic dataset after the initiation of the contrast injection. Diagnostic performance was compared with invasive fractional flow reserve (FFR) &lt;0.8 as the reference. Of the 125 coronary vessels in 42 patients, 20 (16.0%) in 16 (38.1%) patients were categorized as hemodynamically significant. Dynamic and static CTP yielded similar diagnostic accuracy (90.4% vs 88.8% using visual analysis, <jats:italic toggle=\"yes\">P<\/jats:italic> = .558; 77.6% vs 80.8% using quantitative analysis, <jats:italic toggle=\"yes\">P<\/jats:italic> = .534; 78.4% vs 82.4% using combined visual and quantitative analyses, <jats:italic toggle=\"yes\">P<\/jats:italic> = .426). The diagnostic accuracy of combined coronary computed tomography angiography (CCTA) and dynamic CTP (89.6% using visual analysis, <jats:italic toggle=\"yes\">P<\/jats:italic> = .011; 88.8% using quantitative analysis, <jats:italic toggle=\"yes\">P<\/jats:italic> = .018; 89.6% using combined visual and quantitative analyses, <jats:italic toggle=\"yes\">P<\/jats:italic> = .011) and that of combined CCTA and static CTP (88.8% using visual analysis, <jats:italic toggle=\"yes\">P<\/jats:italic> = .018; 90.4% using quantitative analysis, <jats:italic toggle=\"yes\">P<\/jats:italic> = .006; 91.2% using combined visual and quantitative analyses, <jats:italic toggle=\"yes\">P<\/jats:italic> = .003) were significantly higher than that of CCTA alone (77.6%). Dynamic CTP and static CTP showed similar diagnostic performance in the detection of hemodynamically significant stenosis.<\/jats:p>","DOI":"10.1097\/md.0000000000030477","type":"journal-article","created":{"date-parts":[[2022,9,9]],"date-time":"2022-09-09T19:20:44Z","timestamp":1662751244000},"page":"e30477","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Comparison of diagnostic performance between dynamic versus static adenosine-stress myocardial CT perfusion to detect hemodynamically significant coronary artery stenosis: A prospective multicenter study"],"prefix":"10.1097","volume":"101","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1800-8548","authenticated-orcid":false,"given":"Ji Won","family":"Lee","sequence":"first","affiliation":[{"name":"Department of Radiology, Pusan National University School of Medicine and Medical Research Institute, Pusan National University Hospital, Busan, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yeon Hyeon","family":"Choe","sequence":"additional","affiliation":[{"name":"Department of Radiology, Sungkyunkwan University School of Medicine, Seoul, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sung Mok","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Radiology, Sungkyunkwan University School of Medicine, Seoul, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin-Ho","family":"Choi","sequence":"additional","affiliation":[{"name":"Emergency Medicine and Cardiovascular Imaging Center, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seongyong","family":"Pak","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ki Seok","family":"Choo","sequence":"additional","affiliation":[{"name":"Department of Radiology, Pusan National University School of Medicine and Medical Research Institute, Pusan National University Yangsan Hospital, Yangsan-si, Gyeongsangnam-do, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeong Su","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Pusan National University School of Medicine and Medical Research Institute, Pusan National University Yangsan Hospital, Yangsan-si, Gyeongsangnam-do, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chong Eun","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Radiology, Chonnam National University Hospital, Chonnam National University Medical School, Gwangju, Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yun-Hyeon","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Radiology, Chonnam National University Hospital, Chonnam National University Medical School, Gwangju, Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250504","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1007\/s10554-010-9690-4","article-title":"Diagnostic accuracy of first generation dual-source computed tomography in the assessment of coronary artery disease: a meta-analysis from 24 studies.","volume":"27","author":"Guo","year":"2011","journal-title":"Int J Cardiovasc Imaging"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"2345","DOI":"10.1007\/s00330-014-3221-y","article-title":"Meta-analysis: diagnostic accuracy of coronary CT angiography with prospective ECG gating based on step-and-shoot, Flash and volume modes for detection of coronary artery disease.","volume":"24","author":"Yang","year":"2014","journal-title":"Eur Radiol"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"2816","DOI":"10.1016\/j.jacc.2009.11.096","article-title":"Angiographic versus functional severity of coronary artery stenoses in the FAME study fractional flow reserve versus angiography in multivessel evaluation.","volume":"55","author":"Tonino","year":"2010","journal-title":"J Am Coll Cardiol"},{"key":"R4-20250504","doi-asserted-by":"crossref","first-page":"636","DOI":"10.1016\/j.jacc.2008.05.024","article-title":"Comprehensive assessment of coronary artery stenoses: computed tomography coronary angiography versus conventional coronary angiography and correlation with fractional flow reserve in patients with stable angina.","volume":"52","author":"Meijboom","year":"2008","journal-title":"J Am Coll Cardiol"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1016\/j.jcin.2009.03.009","article-title":"On the inappropriateness of noninvasive multidetector computed tomography coronary angiography to trigger coronary revascularization: a comparison with invasive angiography.","volume":"2","author":"Sarno","year":"2009","journal-title":"JACC Cardiovasc Interv"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"11658","DOI":"10.1038\/s41598-020-68292-9","article-title":"Blood residence time to assess significance of coronary artery stenosis.","volume":"10","author":"Hashemi","year":"2020","journal-title":"Sci Rep"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1056\/NEJMoa0807611","article-title":"Fractional flow reserve versus angiography for guiding percutaneous coronary intervention.","volume":"360","author":"Tonino","year":"2009","journal-title":"N Engl J Med"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"2105","DOI":"10.1016\/j.jacc.2007.01.087","article-title":"Percutaneous coronary intervention of functionally nonsignificant stenosis: 5-year follow-up of the DEFER Study.","volume":"49","author":"Pijls","year":"2007","journal-title":"J Am Coll Cardiol"},{"key":"R9-20250504","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1056\/NEJMoa1205361","article-title":"Fractional flow reserve-guided PCI versus medical therapy in stable coronary disease.","volume":"367","author":"De Bruyne","year":"2012","journal-title":"N Engl J Med"},{"key":"R10-20250504","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1016\/j.jcct.2016.09.003","article-title":"Diagnostic accuracy of static CT perfusion for the detection of myocardial ischemia. A systematic review and meta-analysis.","volume":"10","author":"Sorgaard","year":"2016","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"R11-20250504","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1016\/j.ijcard.2018.01.095","article-title":"Dynamic stress computed tomography myocardial perfusion for detecting myocardial ischemia: a systematic review and meta-analysis.","volume":"258","author":"Lu","year":"2018","journal-title":"Int J Cardiol"},{"key":"R12-20250504","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1007\/s12410-018-9456-2","article-title":"Myocardial assessment with cardiac CT: ischemic heart disease and beyond.","volume":"11","author":"Ramsey","year":"2018","journal-title":"Curr Cardiovasc Imaging Rep"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1148\/radiol.13121441","article-title":"Myocardium: dynamic versus single-shot CT perfusion imaging.","volume":"269","author":"Huber","year":"2013","journal-title":"Radiology"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"1234","DOI":"10.1016\/j.acra.2013.07.003","article-title":"Effect of high-pitch dual-source CT to compensate motion artifacts: a phantom study.","volume":"20","author":"Farshad-Amacker","year":"2013","journal-title":"Acad Radiol"},{"key":"R15-20250504","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/j.jcct.2009.01.001","article-title":"SCCT guidelines for the interpretation and reporting of coronary computed tomographic angiography.","volume":"3","author":"Raff","year":"2009","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"R16-20250504","doi-asserted-by":"crossref","first-page":"338","DOI":"10.1016\/j.jcmg.2017.10.025","article-title":"Incremental diagnostic value of stress computed tomography myocardial perfusion with whole-heart coverage CT scanner in intermediate- to high-risk symptomatic patients suspected of coronary artery disease.","volume":"12","author":"Pontone","year":"2019","journal-title":"JACC Cardiovasc Imag"},{"key":"R17-20250504","first-page":"539","article-title":"Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association.","volume":"18","author":"Cerqueira","year":"2002","journal-title":"Int J Cardiovasc Imaging"},{"key":"R18-20250504","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1016\/j.jcmg.2017.06.006","article-title":"Cardiac-specific conversion factors to estimate radiation effective dose from dose-length product in computed tomography.","volume":"11","author":"Trattner","year":"2018","journal-title":"JACC Cardiovasc Imag"},{"key":"R19-20250504","doi-asserted-by":"crossref","first-page":"e007041","DOI":"10.1161\/CIRCINTERVENTIONS.118.007041","article-title":"Revisiting the optimal fractional flow reserve and instantaneous wave-free ratio thresholds for predicting the physiological significance of coronary artery disease.","volume":"11","author":"Modi","year":"2018","journal-title":"Circ Cardiovasc Interv"},{"key":"R20-20250504","doi-asserted-by":"crossref","first-page":"2928","DOI":"10.1161\/01.CIR.103.24.2928","article-title":"Fractional flow reserve to determine the appropriateness of angioplasty in moderate coronary stenosis: a randomized trial.","volume":"103","author":"Bech","year":"2001","journal-title":"Circulation"},{"key":"R21-20250504","doi-asserted-by":"crossref","first-page":"836","DOI":"10.1093\/ehjci\/jew044","article-title":"Static and dynamic assessment of myocardial perfusion by computed tomography.","volume":"17","author":"Danad","year":"2016","journal-title":"Eur Heart J Cardiovasc Imag"},{"key":"R22-20250504","doi-asserted-by":"crossref","first-page":"1097","DOI":"10.1016\/j.jcmg.2012.09.004","article-title":"Combined CT coronary angiography and stress myocardial perfusion imaging for hemodynamically significant stenoses in patients with suspected coronary artery disease: a comparison with fractional flow reserve.","volume":"5","author":"Ko","year":"2012","journal-title":"JACC Cardiovasc Imag"},{"key":"R23-20250504","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1093\/ehjci\/jet133","article-title":"Diagnostic performance of hyperaemic myocardial blood flow index obtained by dynamic computed tomography: does it predict functionally significant coronary lesions?","volume":"15","author":"Rossi","year":"2014","journal-title":"Eur Heart J Cardiovasc Imag"},{"key":"R24-20250504","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1016\/j.jcct.2019.09.003","article-title":"Dynamic CT myocardial perfusion imaging.","volume":"14","author":"Nieman","year":"2020","journal-title":"J Cardiovasc Comput Tomogr"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000030477","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T05:29:28Z","timestamp":1746336568000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000030477"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,9]]},"references-count":24,"journal-issue":{"issue":"36","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000030477","relation":{},"ISSN":["1536-5964"],"issn-type":[{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,9]]}}}