{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,8]],"date-time":"2026-02-08T04:00:03Z","timestamp":1770523203321,"version":"3.49.0"},"reference-count":31,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"41","license":[{"start":{"date-parts":[[2022,10,14]],"date-time":"2022-10-14T00:00:00Z","timestamp":1665705600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,10,14]]},"abstract":"<jats:p>Because burst fractures often involve damage to the column and posterior structures of the spine, the fracture block may invade the spinal canal and compress the spinal cord or the cauda equina, causing corresponding neurological dysfunction. When a thoracolumbar burst fracture is accompanied by the presence of bone in the spinal canal, whether posterior surgery requires spinal canal incision decompression is still controversial. Computed tomography images of the thoracolumbar spine of a 31-year-old male with an L1 burst fracture and Mimics 10.0 were used to establish a three-dimensional fracture model for simulating the indirect reduction process. The model was imported into Ansys 10.0 (ANSYS, Inc., Canonsburg, PA), and a 1 to 10 mm displacement was loaded 10\u00b0 behind the Z-axis on the upper endplate of the L1 vertebral body to simulate position reduction and open reduction. The displacement and stress changes in the intervertebral disc, fractured vertebral body and posterior longitudinal ligament were observed during reduction. Under a displacement loaded 10\u00b0 behind the Z-axis, the maximum stress in the vertebral body was concentrated on the upper disc of the injured vertebrae. The maximum displacement was in the anterior edge of the vertebral body of the injured vertebrae, and the vertebral body height and the anterior lobes were essentially restored. When the displacement load was applied in the positive Z-axis direction, the maximum displacement was in the posterior longitudinal ligament behind the injured vertebrae. Under a 6 mm load, the posterior longitudinal ligament displacement was 11.3 mm. Under an 8 mm load, this displacement significantly increased to 15.0 mm, and the vertebral stress was not concentrated on the intervertebral disc. A reduction in the thoracolumbar burst fractures by positioning and distraction allowed the injured vertebrae to be restored to normal height and kyphosis. The reduction in the posterior longitudinal ligament can push the bone block in the spinal canal into the reset space and achieve a good reset.<\/jats:p>","DOI":"10.1097\/md.0000000000030965","type":"journal-article","created":{"date-parts":[[2022,10,14]],"date-time":"2022-10-14T23:13:16Z","timestamp":1665789196000},"page":"e30965","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":7,"title":["Finite element analysis of the indirect reduction of posterior pedicle screw fixation for a thoracolumbar burst fracture"],"prefix":"10.1097","volume":"101","author":[{"given":"Yuanzheng","family":"Song","sequence":"first","affiliation":[{"name":"Department of Orthopaedics, Tengzhou Central People\u2019s Hospital Affiliated to Jining Medical University, Tengzhou, Shandong Province, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xia","family":"Pang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Tengzhou Central People\u2019s Hospital Affiliated to Jining Medical University, Tengzhou, Shandong Province, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1686-7050","authenticated-orcid":false,"given":"Fahao","family":"Zhu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Tengzhou Central People\u2019s Hospital Affiliated to Jining Medical University, Tengzhou, Shandong Province, China."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250504","doi-asserted-by":"crossref","first-page":"193","DOI":"10.23736\/S0390-5616.19.04628-9","article-title":"Reconstruction of vertebral body in thoracolumbar AO type A post-traumatic fractures by balloon kyphoplasty: a series of 85 patients with a long follow-up and review of the literature.","volume":"66","author":"Francaviglia","year":"2022","journal-title":"J Neurosurg Sci"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"150","DOI":"10.4184\/asj.2017.11.1.150","article-title":"Short segment versus long segment pedicle screws fixation in management of thoracolumbar burst fractures: meta-analysis.","volume":"11","author":"Aly","year":"2017","journal-title":"Asian Spine J"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1016\/j.pjnns.2015.08.005","article-title":"Thoracolumbar burst fractures requiring instrumented fusion: should reducted bone fragments be removed? A retrospective study.","volume":"49","author":"Yaldiz","year":"2015","journal-title":"Neurol Neurochir Pol"},{"key":"R4-20250504","doi-asserted-by":"crossref","first-page":"406","DOI":"10.25259\/SNI_611_2021","article-title":"Transdural reduction of a bone fragment protruding into the spinal canal during surgical treatment of lumbar burst fracture: a case report.","volume":"12","author":"Saruta","year":"2021","journal-title":"Surg Neurol Int"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.jocn.2020.11.044","article-title":"Orthosis versus no orthosis for the treatment of thoracolumbar burst fractures: a systematic review.","volume":"85","author":"Mulcahy","year":"2021","journal-title":"J Clin Neurosci"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1016\/j.jor.2016.06.007","article-title":"Management of burst fractures in the thoracolumbar spine.","volume":"13","author":"Cahueque","year":"2016","journal-title":"J Orthop"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"e99156","DOI":"10.1371\/journal.pone.0099156","article-title":"Treatment of unstable thoracolumbar fractures through short segment pedicle screw fixation techniques using pedicle fixation at the level of the fracture: a finite element analysis.","volume":"9","author":"Li","year":"2014","journal-title":"PLoS One"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"21514593221107509","DOI":"10.1177\/21514593221107509","article-title":"Efficacy and safety of posterior long-segment fixation versus posterior short-segment fixation for kummell disease: a meta-analysis.","volume":"13","author":"Yu","year":"2022","journal-title":"Geriatr Orthop Surg Rehabil"},{"key":"R9-20250504","doi-asserted-by":"crossref","first-page":"669","DOI":"10.21037\/atm-21-881","article-title":"A comparison of monoaxial pedicle screw versus polyaxial pedicle screw in short-segment posterior fixation for the treatment of thoracolumbar fractured vertebra.","volume":"9","author":"Yao","year":"2021","journal-title":"Ann Transl Med"},{"key":"R10-20250504","doi-asserted-by":"crossref","first-page":"55","DOI":"10.14444\/8006","article-title":"Outcomes of thoracolumbar fracture-dislocation managed by short-segment and long-segment posterior fixation: a single-center retrospective study.","volume":"15","author":"Mittal","year":"2021","journal-title":"Int J Spine Surg"},{"key":"R11-20250504","doi-asserted-by":"crossref","first-page":"2195","DOI":"10.1007\/s00586-011-1875-6","article-title":"Thoracolumbar burst fractures with a neurological deficit treated with posterior decompression and interlaminar fusion.","volume":"20","author":"Ge","year":"2011","journal-title":"Eur Spine J"},{"key":"R12-20250504","doi-asserted-by":"crossref","first-page":"38","DOI":"10.21037\/acr.2018.07.02","article-title":"Surgical reduction technique (transpedicle) for unstable thoracolumbar burst fractures with retropulsion resulting in severe spinal canal stenosis: a preliminary case report.","volume":"2","author":"Choo","year":"2018","journal-title":"AME Case Rep"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"e20276","DOI":"10.1097\/MD.0000000000020276","article-title":"Percutaneous pedicle screw fixation combined with transforaminal endoscopic spinal canal decompression for the treatment of thoracolumbar burst fracture with severe neurologic deficit: a case report.","volume":"99","author":"Huang","year":"2020","journal-title":"Medicine (Baltim)"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"532","DOI":"10.1186\/s13018-020-02075-w","article-title":"Effect of manual reduction and indirect decompression on thoracolumbar burst fracture: a comparison study.","volume":"15","author":"Huang","year":"2020","journal-title":"J Orthop Surg Res"},{"key":"R15-20250504","first-page":"973","article-title":"Efficiency of distraction and ligamentotaxis in posterior spinal instrumentation of thoracolumbar retropulsed fractures.","volume":"31","author":"Benek","year":"2021","journal-title":"Turk Neurosurg"},{"key":"R16-20250504","doi-asserted-by":"crossref","first-page":"1329","DOI":"10.1007\/s00264-008-0626-8","article-title":"Fluoroscopically-guided indirect posterior reduction and fixation of thoracolumbar burst fractures without fusion.","volume":"33","author":"Yang","year":"2009","journal-title":"Int Orthop"},{"key":"R17-20250504","doi-asserted-by":"crossref","first-page":"1482","DOI":"10.1097\/BRS.0b013e318297bdb7","article-title":"Short-segment fixation without fusion for thoracolumbar burst fractures with neurological deficit can preserve thoracolumbar motion without resulting in post-traumatic disc degeneration: a 10-year follow-up study.","volume":"38","author":"Toyone","year":"2013","journal-title":"Spine (Phila Pa 1976)"},{"key":"R18-20250504","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1016\/0021-9290(74)90019-0","article-title":"Finite element stress analysis of an intervertebral disc.","volume":"7","author":"Belytschko","year":"1974","journal-title":"J Biomech"},{"key":"R19-20250504","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1186\/s40001-022-00769-x","article-title":"Finite element analysis of dynamic changes in spinal mechanics of osteoporotic lumbar fracture.","volume":"27","author":"Yan","year":"2022","journal-title":"Eur J Med Res"},{"key":"R20-20250504","doi-asserted-by":"crossref","first-page":"8872514","DOI":"10.1155\/2021\/8872514","article-title":"A finite element study on the treatment of thoracolumbar fracture with a new spinal fixation system.","volume":"2021","author":"Guo","year":"2021","journal-title":"Biomed Res Int"},{"key":"R21-20250504","doi-asserted-by":"crossref","first-page":"071007","DOI":"10.1115\/1.4050537","article-title":"Comparison of posterior fixation strategies for thoracolumbar burst fracture: a finite element study.","volume":"143","author":"Wong","year":"2021","journal-title":"J Biomech Eng"},{"key":"R22-20250504","doi-asserted-by":"crossref","first-page":"455","DOI":"10.3390\/diagnostics11030455","article-title":"MDCT-based finite element analyses: are measurements at the lumbar spine associated with the biomechanical strength of functional spinal units of incidental osteoporotic fractures along the thoracolumbar spine?","volume":"11","author":"Sollmann","year":"2021","journal-title":"Diagnostics (Basel)"},{"key":"R23-20250504","doi-asserted-by":"crossref","first-page":"6497754","DOI":"10.1155\/2022\/6497754","article-title":"Mechanical analysis of posterior pedicle screw system placement and internal fixation in the treatment of lumbar fractures.","volume":"2022","author":"Mu","year":"2022","journal-title":"Comput Math Methods Med"},{"key":"R24-20250504","doi-asserted-by":"crossref","first-page":"706597","DOI":"10.3389\/fsurg.2021.706597","article-title":"Biomechanical evaluation of the transcortical and transpedicular trajectories for pedicle screw insertion in thoracolumbar fracture fixation for ankylosing spondylitis.","volume":"8","author":"Tong","year":"2021","journal-title":"Front Surg"},{"key":"R25-20250504","doi-asserted-by":"crossref","first-page":"2949419","DOI":"10.1155\/2021\/2949419","article-title":"Finite element analysis of a novel anterior locking plate for thoracolumbar burst fracture.","volume":"2021","author":"Ren","year":"2021","journal-title":"Biomed Res Int"},{"key":"R26-20250504","doi-asserted-by":"crossref","first-page":"2497","DOI":"10.1007\/s00586-015-3955-5","article-title":"Single-stage posterior vertebral column resection and internal fixation for old fracture-dislocations of thoracolumbar spine: a case series and systematic review.","volume":"25","author":"Tang","year":"2016","journal-title":"Eur Spine J"},{"key":"R27-20250504","doi-asserted-by":"crossref","first-page":"4132","DOI":"10.1007\/s00586-016-4738-3","article-title":"Anatomical variations of the foramen transversarium in cervical vertebrae: findings, review of the literature, and clinical significance during cervical spine surgery.","volume":"25","author":"Zibis","year":"2016","journal-title":"Eur Spine J"},{"key":"R28-20250504","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1016\/j.spinee.2016.08.027","article-title":"Commentary on development and assessment of a digital X-ray software tool to determine vertebral rotation in adolescent idiopathic scoliosis.","volume":"17","author":"Jain","year":"2017","journal-title":"Spine J"},{"key":"R29-20250504","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1302\/0301-620X.96B4.33249","article-title":"Short segment pedicle screw instrumentation with an index level screw and cantilevered hyperlordotic reduction in the treatment of type-A fractures of the thoracolumbar spine.","volume":"96-B","author":"Kose","year":"2014","journal-title":"Bone Joint J"},{"key":"R30-20250504","first-page":"2754","article-title":"Correlations between posterior longitudinal ligament status and size of bone fragment in thoracolumbar burst fractures.","volume":"8","author":"Hu","year":"2015","journal-title":"Int J Clin Exp Med"},{"key":"R31-20250504","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.clineuro.2015.05.016","article-title":"Percutaneous versus open pedicle screw fixation for treatment of thoracolumbar fractures: systematic review and meta-analysis of comparative studies.","volume":"135","author":"Phan","year":"2015","journal-title":"Clin Neurol Neurosurg"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000030965","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T05:28:02Z","timestamp":1746336482000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000030965"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,14]]},"references-count":31,"journal-issue":{"issue":"41","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000030965","relation":{},"ISSN":["1536-5964"],"issn-type":[{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,10,14]]}}}