{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,20]],"date-time":"2026-02-20T05:27:37Z","timestamp":1771565257061,"version":"3.50.1"},"reference-count":22,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"45","license":[{"start":{"date-parts":[[2022,11,11]],"date-time":"2022-11-11T00:00:00Z","timestamp":1668124800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,11,11]]},"abstract":"<jats:p>The purpose of this study was to identify the criteria for atlantoaxial (AA) fusion by comparing follow-up lateral radiographs and computed tomography (CT) images. We retrospectively analyzed data from 161 consecutive patients undergoing AA fusion. Patients with a minimum of 1 year of CT follow-up after AA fusion surgery using C2 pedicle screws or translaminar screws (C2TLS) were included. Patients were followed up radiographically at 3, 6, and 12 months after surgery, and dynamic lateral radiographs were also evaluated. A total of 49 patients were analyzed, with a mean CT image follow-up of 41.6\u2005\u00b1\u200537.6 months. Thirty eight patients had C2 pedicle screw placement, and 11 patients underwent planned C2TLS. AA fusion with bridging bone mass formation was achieved in 45\/49 (91.8%) patients. Screw halos were observed in 14\/49 (28.6%) patients. Among them, final fusion failure occurred in 2 (14.3%) patients. The last follow-up CT showed no difference in the fusion failure rate according to the presence or absence of a screw halo (no halo, 5.7%; halo, 14.3%; <jats:italic toggle=\"yes\">P<\/jats:italic>\u2005=\u2005.33). The differences in C1-2 segmental angles (SA) in flexion-extension dynamic lateral radiographs were 1.99\u2005\u00b1\u20051.62\u00b0 in the fusion group and 4.37\u2005\u00b1\u20052.13\u00b0 in the non-fusion group (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2005=\u2005.01). The likelihood of fusion failure increased when the SA gap was greater than 2.62\u00b0 (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2005=\u2005.05). C2TLS placement had a significantly higher incidence of screw halos. However, the halo sign was not significantly related to final bone fusion. Bone fusion could be predicted when the SA gap of C1-2 was less than 2.62\u00b0 on the dynamic radiograph.<\/jats:p>","DOI":"10.1097\/md.0000000000031496","type":"journal-article","created":{"date-parts":[[2022,11,17]],"date-time":"2022-11-17T14:03:59Z","timestamp":1668693839000},"page":"e31496","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["Radiological evaluation of atlantoaxial fusion using C2 translaminar screws and C2 pedicle screws: Does the screw halo sign imply fusion failure?"],"prefix":"10.1097","volume":"101","author":[{"given":"Subum","family":"Lee","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Korea University Anam Hospital, College of Medicine Korea University, Seoul, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Junseok W","family":"Hur","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Korea University Anam Hospital, College of Medicine Korea University, Seoul, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jang-Bo","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Korea University Anam Hospital, College of Medicine Korea University, Seoul, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jin Hoon","family":"Park","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daewon","family":"Park","sequence":"additional","affiliation":[{"name":"Spine Center, Good Moonhwa Hospital, Busan, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sang-Jin","family":"Park","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Charmjoeun Spine and Joint Hospital, Daegu, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kyoung-Tae","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, School of Medicine, Kyungpook National University, Kyungpook National University Hospital, Daegu, Republic of Korea."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2899-8015","authenticated-orcid":false,"given":"Dae-Chul","family":"Cho","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, School of Medicine, Kyungpook National University, Kyungpook National University Hospital, Daegu, Republic of Korea."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250504","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1007\/BF01400872","article-title":"Plate and screw fixation for atlanto-axial subluxation","volume":"129","author":"Goel","year":"1994","journal-title":"Acta Neurochir (Wien)"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"2467","DOI":"10.1097\/00007632-200111150-00014","article-title":"Posterior C1-C2 fusion with polyaxial screw and rod fixation","volume":"26","author":"Harms","year":"2001","journal-title":"Spine (Phila Pa 1976)"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1016\/j.clineuro.2011.11.001","article-title":"Clinical outcome of posterior fixation of the C1 lateral mass and C2 pedicle by polyaxial screw and rod","volume":"114","author":"Jeon","year":"2012","journal-title":"Clin Neurol Neurosurg"},{"key":"R4-20250504","doi-asserted-by":"crossref","first-page":"1592","DOI":"10.1016\/j.jocn.2009.03.026","article-title":"Posterior C1 lateral mass and C2 pedicle screw internal fixation for atlantoaxial instability","volume":"16","author":"Xie","year":"2009","journal-title":"J Clin Neurosci"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"52","DOI":"10.3171\/2018.6.SPINE171390","article-title":"Differences in fixation strength among constructs of atlantoaxial fixation","volume":"30","author":"Chang","year":"2018","journal-title":"J Neurosurg Spine"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"409","DOI":"10.3171\/spi.2005.3.5.0409","article-title":"Translaminar rigid screw fixation of the axis. Technical note","volume":"3","author":"Wright","year":"2005","journal-title":"J Neurosurg Spine"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1097\/BSD.0b013e318218a4f7","article-title":"Feasibility of C2 translaminar screw as an alternative or salvage of C2 pedicle screws in atlantoaxial instability","volume":"25","author":"Park","year":"2012","journal-title":"J Spinal Disord Tech"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"151","DOI":"10.3171\/2014.10.SPINE13805","article-title":"Biomechanical analysis of screw constructs for atlantoaxial fixation in cadavers: a systematic review and meta-analysis","volume":"22","author":"Du","year":"2015","journal-title":"J Neurosurg Spine"},{"key":"R9-20250504","doi-asserted-by":"crossref","first-page":"639","DOI":"10.3171\/2011.1.SPINE10446","article-title":"Biomechanical analysis of Goel technique for C1-2 fusion","volume":"14","author":"Park","year":"2011","journal-title":"J Neurosurg Spine"},{"key":"R10-20250504","doi-asserted-by":"crossref","first-page":"682","DOI":"10.1016\/j.spinee.2006.08.010","article-title":"Atlantoaxial fusion: a biomechanical analysis of two C1-C2 fusion techniques","volume":"7","author":"Claybrooks","year":"2007","journal-title":"Spine J"},{"key":"R11-20250504","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1177\/2192568218765995","article-title":"Biomechanics and clinical application of translaminar screws fixation in spine: a review of the literature","volume":"9","author":"Chan","year":"2019","journal-title":"Global Spine J"},{"key":"R12-20250504","doi-asserted-by":"crossref","first-page":"396","DOI":"10.3171\/2009.5.SPINE08662","article-title":"Use of allograft bone for posterior C1-2 fusion","volume":"11","author":"Hillard","year":"2009","journal-title":"J Neurosurg Spine"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"1491","DOI":"10.1227\/NEU.0b013e318212a4d7","article-title":"7 years of experience with C2 translaminar screw fixation: clinical series and review of the literature","volume":"68","author":"Dorward","year":"2011","journal-title":"Neurosurgery"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"237","DOI":"10.3340\/jkns.2019.0172","article-title":"Comparative analysis of surgical outcomes of C1-2 fusion spine surgery between intraoperative computed tomography image based navigation-guided operation and fluoroscopy-guided operation","volume":"63","author":"Lee","year":"2020","journal-title":"J Korean Neurosurg Soc"},{"key":"R15-20250504","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1016\/j.jocn.2012.01.045","article-title":"Modified C1 lateral mass screw insertion using a high entry point to avoid postoperative occipital neuralgia","volume":"20","author":"Lee","year":"2013","journal-title":"J Clin Neurosci"},{"key":"R16-20250504","doi-asserted-by":"crossref","first-page":"1005","DOI":"10.1007\/s00586-015-3768-6","article-title":"Pedicle screw loosening: a clinically relevant complication?.","volume":"24","author":"Galbusera","year":"2015","journal-title":"Eur Spine J"},{"key":"R17-20250504","doi-asserted-by":"crossref","first-page":"598","DOI":"10.1177\/2192568219864341","article-title":"Screw loosening in posterior spine fusion: prevalence and risk factors","volume":"10","author":"Marie-Hardy","year":"2019","journal-title":"Global Spine J"},{"key":"R18-20250504","doi-asserted-by":"crossref","first-page":"1895","DOI":"10.1097\/BRS.0000000000002305","article-title":"Pedicle screw loosening after posterior spinal fusion for adolescent idiopathic scoliosis in upper and lower instrumented vertebrae having major perforation","volume":"42","author":"Uehara","year":"2017","journal-title":"Spine"},{"key":"R19-20250504","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1302\/0301-620X.86B3.14323","article-title":"The significance of radiolucent zones surrounding pedicle screws. Definition of screw loosening in spinal instrumentation","volume":"86","author":"Sand\u00e9n","year":"2004","journal-title":"J Bone Joint Surg Br"},{"key":"R20-20250504","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1097\/BRS.0b013e3181976aa9","article-title":"Acute and long-term stability of atlantoaxial fixation methods: a biomechanical comparison of pars, pedicle, and intralaminar fixation in an intact and odontoid fracture model","volume":"34","author":"Dmitriev","year":"2009","journal-title":"Spine (Phila Pa 1976)"},{"key":"R21-20250504","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1097\/BCO.0000000000000846","article-title":"Translational medicine: challenges and new orthopaedic vision (mediouni-model)","volume":"31","author":"Mediouni","year":"2020","journal-title":"Curr Orthop Pract"},{"key":"R22-20250504","doi-asserted-by":"crossref","first-page":"1217","DOI":"10.1080\/03007995.2017.1385450","article-title":"A review of translational medicine. The future paradigm: how can we connect the orthopedic dots better?.","volume":"34","author":"Mediouni","year":"2018","journal-title":"Curr Med Res Opin"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000031496","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T05:02:28Z","timestamp":1746334948000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000031496"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,11]]},"references-count":22,"journal-issue":{"issue":"45","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000031496","relation":{},"ISSN":["1536-5964"],"issn-type":[{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,11,11]]}}}