{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T10:35:09Z","timestamp":1787654109095,"version":"build-2736575974"},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","license":[{"start":{"date-parts":[[2023,2,10]],"date-time":"2023-02-10T00:00:00Z","timestamp":1675987200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,2,10]]},"abstract":"<jats:p>Studies comparing the detection of clean mucosal areas in capsule endoscopy (CE) using human judgment versus artificial intelligence (AI) are rare. This study statistically analyzed gastroenterologist judgments and AI results. Three hundred CE video clips (100 patients) were prepared. Five gastroenterologists classified the video clips into 3 groups (\u226575% [high], 50%\u201375% [middle], and\u2005&lt;\u200550% [low]) according to their subjective judgment of cleanliness. Visualization scores were calculated using an AI algorithm based on the predicted visible area, and the 5 gastroenterologists\u2019 judgments and AI results were compared. The 5 gastroenterologists evaluated CE clip video quality as \u201chigh\u201d in 10.7% to 36.7% and as \u201clow\u201d in 28.7% to 60.3% and 29.7% of cases, respectively. The AI evaluated CE clip video quality as \u201chigh\u201d in 27.7% and as \u201clow\u201d in 29.7% of cases. Repeated-measures analysis of variance (ANOVA) revealed significant differences in the 6 evaluation indicators (5 gastroenterologists and 1 AI) (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2005&lt;\u2005.001). Among the 300 judgments, 90 (30%) were consistent with 5 gastroenterologists\u2019 judgments, and 82 (91.1%) agreed with the AI judgments. The \u201chigh\u201d and \u201clow\u201d judgments of the gastroenterologists and AI agreed in 95.0% and 94.9% of cases, respectively. Bonferroni\u2019s multiple comparison test showed no significant difference between 3 gastroenterologists and AI (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2005=\u2005.0961, <jats:italic toggle=\"yes\">P<\/jats:italic>\u2005=\u20051.0000, and <jats:italic toggle=\"yes\">P<\/jats:italic>\u2005=\u2005.0676, respectively) but a significant difference between the other 2 with AI (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2005&lt;\u2005.0001). When evaluating CE images for cleanliness, the judgments of 5 gastroenterologists were relatively diverse. The AI produced a relatively universal judgment that was consistent with the gastroenterologists\u2019 judgements.<\/jats:p>","DOI":"10.1097\/md.0000000000032883","type":"journal-article","created":{"date-parts":[[2023,2,10]],"date-time":"2023-02-10T16:38:53Z","timestamp":1676047133000},"page":"e32883","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":11,"title":["Clean mucosal area detection of gastroenterologists versus artificial intelligence in small bowel capsule endoscopy"],"prefix":"10.1097","volume":"102","author":[{"given":"Jeongwoo","family":"Ju","sequence":"first","affiliation":[{"name":"Captos Co., Ltd., Yangsan, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hyun Sook","family":"Oh","sequence":"additional","affiliation":[{"name":"Department of Applied Statistics, School of Social Science, Gachon University, Seongnam, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8012-5433","authenticated-orcid":false,"given":"Yeoun Joo","family":"Lee","sequence":"additional","affiliation":[{"name":"Captos Co., Ltd., Yangsan, Korea"},{"name":"Department of Pediatrics, Pusan National University School of Medicine, Pusan National University Yangsan Hospital, Yangsan, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Heechul","family":"Jung","sequence":"additional","affiliation":[{"name":"Captos Co., Ltd., Yangsan, Korea"},{"name":"Department of Artificial Intelligence, Kyungpook National University, Daegu, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jong-Hyuck","family":"Lee","sequence":"additional","affiliation":[{"name":"Captos Co., Ltd., Yangsan, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ben","family":"Kang","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, Kyungpook National University School of Medicine, Kyungpook National University Chilgok Hospital, Daegu, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sujin","family":"Choi","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, Kyungpook National University School of Medicine, Kyungpook National University Chilgok Hospital, Daegu, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ji Hyun","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Kangwon National University School of Medicine, Kangwon National University Hospital, Chuncheon, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyeong Ok","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Yeungnam University College of Medicine, Yeungnam University Medical Center, Daegu, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yun Jin","family":"Chung","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Kyungpook National University Chilgok Hospital, Daegu, Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250504","doi-asserted-by":"crossref","first-page":"e0154149","DOI":"10.1371\/journal.pone.0154149","article-title":"Meta-Analysis of the effect of bowel preparation on adenoma detection: early adenomas affected stronger than advanced adenomas.","volume":"11","author":"Sulz","year":"2016","journal-title":"PLoS One"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1016\/j.gie.2017.06.012","article-title":"Inadequate Boston Bowel Preparation Scale scores predict the risk of missed neoplasia on the next colonoscopy.","volume":"87","author":"Kluge","year":"2018","journal-title":"Gastrointest Endosc"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"534","DOI":"10.1016\/S0016-5107(04)01879-6","article-title":"Bowel preparation increases the diagnostic yield of capsule endoscopy: a prospective, randomized, controlled study.","volume":"60","author":"Viazis","year":"2004","journal-title":"Gastrointest Endosc"},{"key":"R4-20250504","doi-asserted-by":"crossref","first-page":"E1658","DOI":"10.1055\/a-1529-5814","article-title":"Efficacy of bowel preparation regimens for colon capsule endoscopy: a systematic review and meta-analysis.","volume":"9","author":"Bjoersum-Meyer","year":"2021","journal-title":"Endosc Int Open"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1055\/s-0043-125207","article-title":"Meta-analysis of randomized controlled trials challenging the usefulness of purgative preparation before small-bowel video capsule endoscopy.","volume":"50","author":"Gkolfakis","year":"2018","journal-title":"Endoscopy"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"2400","DOI":"10.3390\/diagnostics12102400","article-title":"Inter\/intra-observer agreement in video-capsule endoscopy: are we getting it all wrong? a systematic review and meta-analysis.","volume":"12","author":"Cortegoso Valdivia","year":"2022","journal-title":"Diagnostics"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"2833","DOI":"10.3748\/wjg.v24.i26.2833","article-title":"Bowel preparation quality scales for colonoscopy.","volume":"24","author":"Kastenberg","year":"2018","journal-title":"World J Gastroenterol"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1016\/j.gie.2008.05.057","article-title":"The Boston bowel preparation scale: a valid and reliable instrument for colonoscopy-oriented research.","volume":"69","author":"Lai","year":"2009","journal-title":"Gastrointest Endosc"},{"key":"R9-20250504","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1093\/gastro\/goz054","article-title":"Evaluating a combined bowel preparation for small-bowel capsule endoscopy: a prospective randomized\u2013controlled study.","volume":"8","author":"Hansel","year":"2019","journal-title":"Gastroenterol Rep"},{"key":"R10-20250504","doi-asserted-by":"crossref","first-page":"979","DOI":"10.1080\/17474124.2017.1359540","article-title":"Systematic review and meta-analysis: is bowel preparation still necessary in small bowel capsule endoscopy?","volume":"11","author":"Yung","year":"2017","journal-title":"Expert Rev Gastroenterol Hepatol"},{"key":"R11-20250504","doi-asserted-by":"crossref","first-page":"397","DOI":"10.3390\/medicina58030397","article-title":"Semantic segmentation dataset for AI-based quantification of clean mucosa in capsule endoscopy.","volume":"58","author":"Ju","year":"2022","journal-title":"Medicina"},{"key":"R12-20250504","doi-asserted-by":"crossref","first-page":"834","DOI":"10.1109\/TPAMI.2017.2699184","article-title":"DeepLab: semantic image segmentation with deep convolutional nets, atrous convolution, and fully connected CRFs.","volume":"40","author":"Chen","year":"2018","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1016\/j.gie.2022.08.039","article-title":"Quality indicators for capsule endoscopy and deep enteroscopy.","volume":"96","author":"Leighton","year":"2022","journal-title":"Gastrointest Endosc"},{"key":"R15-20250504","doi-asserted-by":"crossref","first-page":"E122","DOI":"10.1055\/a-1319-0742","article-title":"Quality performance measures for small capsule endoscopy: are the ESGE quality standards met?","volume":"9","author":"Rondonotti","year":"2021","journal-title":"Endosc Int Open"},{"key":"R16-20250504","doi-asserted-by":"crossref","first-page":"16802810","DOI":"10.1155\/2016\/6802810","article-title":"Optimal bowel preparation for video capsule endoscopy.","volume":"2016","author":"Song","year":"2016","journal-title":"Gastroenterol Res Pract"},{"key":"R17-20250504","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.gie.2020.05.066","article-title":"Ulcer severity grading in video capsule images of patients with Crohn\u2019s disease: an ordinal neural network solution.","volume":"93","author":"Barash","year":"2021","journal-title":"Gastrointest Endosc"},{"key":"R18-20250504","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1093\/jcag\/gwy027","article-title":"Comparison of the boston bowel preparation scale with an auditable application of the US multi-society task force guidelines.","volume":"2","author":"Heron","year":"2019","journal-title":"J Can Assoc Gastroenterol"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000032883","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T03:02:00Z","timestamp":1746327720000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000032883"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2,10]]},"references-count":17,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000032883","relation":{},"ISSN":["0025-7974"],"issn-type":[{"value":"0025-7974","type":"print"}],"subject":[],"published":{"date-parts":[[2023,2,10]]}}}