{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T00:04:50Z","timestamp":1747181090188,"version":"3.40.5"},"reference-count":34,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","license":[{"start":{"date-parts":[[2023,3,24]],"date-time":"2023-03-24T00:00:00Z","timestamp":1679616000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,3,24]]},"abstract":"<jats:p>To evaluate the effects of various patient characteristics on vessel enhancement on arterio-venous fistula (AVF) computed tomography (CT) angiography (AVF-CT angiography). A total of 127 patients with suspected or confirmed shunt stenosis and internal AVF complications were considered for inclusion in a retrospective cohort study. The tube voltage was 120 kVp, and the tube current was changed from 300 to 770 mA to maintain the image quality (noise index: 14) using automatic tube current modulation. To evaluate the effects of age, sex, body size, and scan delay on the CT number of the brachial artery or vein, we used correlation coefficients and multivariate regression analyses. There was a significant positive correlation between the CT number of the brachial artery or vein and age (<jats:italic toggle=\"yes\">R<\/jats:italic>\u2005=\u20050.21 or 0.23, <jats:italic toggle=\"yes\">P<\/jats:italic>\u2005&lt;\u2005.01). The correlations were inverse with the height (r\u2005=\u2005\u22120.45 or \u22120.42), total body weight (r\u2005=\u2005\u22120.52 or \u22120.50), body mass index (r\u2005=\u2005\u22120.21 or \u22120.23), body surface area (body surface area [BSA]; r\u2005=\u2005\u22120.56 or \u22120.54), and lean body weight (r\u2005=\u2005\u22120.55 or \u22120.53) in linear regression analysis (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2005&lt;\u2005.01 for all). There was a significant correlation between the CT number of the brachial artery or vein and scan delay (<jats:italic toggle=\"yes\">R<\/jats:italic>\u2005=\u20050.19 or 01.9, <jats:italic toggle=\"yes\">P<\/jats:italic>\u2005&lt;\u2005.01). Only the BSA had significant effects on the CT number in multivariate regression analysis (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2005&lt;\u2005.01). The BSA was significantly correlated with the CT number of the brachial artery or vein on AVF-CT angiography.<\/jats:p>","DOI":"10.1097\/md.0000000000033328","type":"journal-article","created":{"date-parts":[[2023,3,24]],"date-time":"2023-03-24T13:10:50Z","timestamp":1679663450000},"page":"e33328","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Effect of patient characteristics on vessel enhancement on arterio-venous fistula CT angiography in a retrospective cohort study"],"prefix":"10.1097","volume":"102","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4164-4369","authenticated-orcid":false,"given":"Takanori","family":"Masuda","sequence":"first","affiliation":[{"name":"Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki, Okayama, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takeshi","family":"Nakaura","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshinori","family":"Funama","sequence":"additional","affiliation":[{"name":"Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2941-8449","authenticated-orcid":false,"given":"Tomoyasu","family":"Sato","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, Tsuchiya General Hospital, Naka-ku, Hiroshima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shouko","family":"Masuda","sequence":"additional","affiliation":[{"name":"Department of Radiological Technologist, Kawamura Clinic, Hiroshima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takayuki","family":"Yoshiura","sequence":"additional","affiliation":[{"name":"Department of Radiological Technology, Tsuchiya General Hospital, Naka-ku, Hiroshima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rumi","family":"Gotanda","sequence":"additional","affiliation":[{"name":"Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki, Okayama, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Keiko","family":"Arao","sequence":"additional","affiliation":[{"name":"Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki, Okayama, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiromasa","family":"Imaizumi","sequence":"additional","affiliation":[{"name":"Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki, Okayama, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shinichi","family":"Arao","sequence":"additional","affiliation":[{"name":"Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki, Okayama, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Atsushi","family":"Ono","sequence":"additional","affiliation":[{"name":"Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki, Okayama, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Junichi","family":"Hiratsuka","sequence":"additional","affiliation":[{"name":"Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki, Okayama, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazuo","family":"Awai","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"issue":"4, Supplement 2","key":"R1-20250504","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1053\/j.ajkd.2019.12.001","article-title":"KDOQI clinical practice guideline for vascular access: 2019 update.","volume":"75","author":"Lok","year":"2020","journal-title":"Am J Kidney Dis"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"77","DOI":"10.5414\/CNP69077","article-title":"Early and late fistula failure.","volume":"69","author":"Mercado","year":"2008","journal-title":"Clin Nephrol"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"1261","DOI":"10.1016\/j.transproceed.2006.02.066","article-title":"Complications of arteriovenous fistula in dialysis patients.","volume":"38","author":"Salahi","year":"2006","journal-title":"Transplant Proc"},{"issue":"Suppl 1","key":"R4-20250504","first-page":"S248","article-title":"Clinical practice guidelines for vascular access.","volume":"48","year":"2006","journal-title":"Am J Kidney Dis"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"999","DOI":"10.1053\/j.ajkd.2004.02.012","article-title":"Predialysis nephrologic care and a functioning arteriovenous fistula at entry are associated with better survival in incident hemodialysis patients: an observational cohort study.","volume":"43","author":"Lorenzo","year":"2004","journal-title":"Am J Kidney Dis"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1111\/j.1542-4758.2009.00359.x","article-title":"Hemodialysis vascular access monitoring: current concepts.","volume":"13","author":"Allon","year":"2009","journal-title":"Hemodial Int"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1111\/1744-9987.12073","article-title":"Complications of native arteriovenous fistula: the role of color doppler ultrasonography.","volume":"18","author":"Visciano","year":"2014","journal-title":"Ther Apher Dial"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"1079","DOI":"10.2214\/AJR.08.1620","article-title":"Stenosis detection in native hemodialysis fistulas with MDCT angiography.","volume":"192","author":"Heye","year":"2009","journal-title":"AJR Am J Roentgenol"},{"key":"R9-20250504","doi-asserted-by":"crossref","first-page":"1268","DOI":"10.2214\/AJR.04.1553","article-title":"MDCT angiography for evaluation of the complete vascular tree of hemodialysis fistulas.","volume":"185","author":"Ko","year":"2005","journal-title":"AJR Am J Roentgenol"},{"key":"R10-20250504","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1016\/j.ejrad.2007.09.014","article-title":"Evaluation of failing hemodialysis fistulas with multidetector CT angiography: comparison of different 3D planes.","volume":"69","author":"Karadeli","year":"2009","journal-title":"Eur J Radiol"},{"key":"R11-20250504","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1097\/01.rct.0000191688.43591.20","article-title":"Hemodialysis fistula occlusion: demonstration with 64-slice CT angiography.","volume":"30","author":"Neyman","year":"2006","journal-title":"J Comput Assist Tomogr"},{"key":"R12-20250504","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.diii.2014.06.011","article-title":"Three-dimensional MDCT angiography of splanchnic arteries: pearls and pitfalls.","volume":"96","author":"Dohan","year":"2015","journal-title":"Diagn Interventional Imaging"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1148\/radiol.10090908","article-title":"Intravenous contrast medium administration and scan timing at CT: considerations and approaches.","volume":"256","author":"Bae","year":"2010","journal-title":"Radiology"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"903","DOI":"10.2214\/AJR.09.3460","article-title":"Contrast material injection protocol with the dose adjusted to the body surface area for MDCT aortography.","volume":"194","author":"Yanaga","year":"2010","journal-title":"AJR Am J Roentgenol"},{"key":"R15-20250504","first-page":"F632","article-title":"Estimated lean body mass as an index for normalization of body fluid volumes in humans.","volume":"247","author":"Boer","year":"1984","journal-title":"Am J Physiol"},{"key":"R16-20250504","doi-asserted-by":"crossref","first-page":"1098","DOI":"10.1056\/NEJM198710223171717","article-title":"Simplified calculation of body-surface area.","volume":"317","author":"Mosteller","year":"1987","journal-title":"N Engl J Med"},{"key":"R17-20250504","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1136\/jcp.19.4.389","article-title":"Prediction of lean body mass from height and weight.","volume":"19","author":"Hume","year":"1966","journal-title":"J Clin Pathol"},{"key":"R18-20250504","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1111\/j.1365-2125.1981.tb01163.x","article-title":"Should clearance be normalized to body surface or to lean body mass?","volume":"11","author":"Hallynck","year":"1981","journal-title":"Br J Clin Pharmacol"},{"key":"R19-20250504","doi-asserted-by":"crossref","first-page":"777","DOI":"10.2214\/AJR.07.2765","article-title":"Contrast enhancement in cardiovascular MDCT: effect of body weight, height, body surface area, body mass index, and obesity.","volume":"190","author":"Bae","year":"2008","journal-title":"AJR Am J Roentgenol"},{"key":"R20-20250504","doi-asserted-by":"crossref","first-page":"643","DOI":"10.1016\/j.ejrad.2010.08.037","article-title":"Abdominal multi-detector row CT: effectiveness of determining contrast medium dose on basis of body surface area.","volume":"80","author":"Onishi","year":"2011","journal-title":"Eur J Radiol"},{"key":"R21-20250504","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1097\/RCT.0b013e31827dbc08","article-title":"Contrast enhancement during hepatic computed tomography: effect of total body weight, height, body mass index, blood volume, lean body weight, and body surface area.","volume":"37","author":"Kidoh","year":"2013","journal-title":"J Comput Assist Tomogr"},{"key":"R22-20250504","doi-asserted-by":"crossref","first-page":"265","DOI":"10.3348\/kjr.2018.19.2.265","article-title":"Effect of patient characteristics on vessel enhancement at lower extremity CT angiography.","volume":"19","author":"Masuda","year":"2018","journal-title":"Korean J Radiol"},{"key":"R23-20250504","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1148\/radiology.207.3.9609887","article-title":"Aortic and hepatic contrast medium enhancement at CT. Part II. Effect of reduced cardiac output in a porcine model.","volume":"207","author":"Bae","year":"1998","journal-title":"Radiology"},{"key":"R24-20250504","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1016\/S0899-7071(00)00225-4","article-title":"Diffuse perfusion abnormality of the liver parenchyma on angiography-assisted helical CT in relation to cirrhosis and previous treatments: a potential diagnostic pitfall for detecting hepatocellular carcinoma.","volume":"24","author":"Makita","year":"2000","journal-title":"Clin Imaging"},{"key":"R25-20250504","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1097\/RCT.0000000000000513","article-title":"Aortic and hepatic contrast enhancement during hepatic-arterial and portal venous phase computed tomography scanning: multivariate linear regression analysis using age, sex, total body weight, height, and cardiac output.","volume":"41","author":"Masuda","year":"2017","journal-title":"J Comput Assist Tomogr"},{"key":"R26-20250504","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1023\/A:1010639201787","article-title":"Body surface area as a determinant of pharmacokinetics and drug dosing.","volume":"19","author":"Sawyer","year":"2001","journal-title":"Invest New Drugs"},{"key":"R27-20250504","doi-asserted-by":"crossref","first-page":"1837","DOI":"10.1161\/01.CIR.95.7.1837","article-title":"Stroke volume and cardiac output in normotensive children and adults. Assessment of relations with body size and impact of overweight.","volume":"95","author":"de Simone","year":"1997","journal-title":"Circulation"},{"key":"R28-20250504","doi-asserted-by":"crossref","first-page":"2621","DOI":"10.1681\/ASN.2014101017","article-title":"Maintenance dialysis throughout the world in years 1990 and 2010.","volume":"26","author":"Thomas","year":"2015","journal-title":"J Am Soc Nephrol"},{"key":"R29-20250504","doi-asserted-by":"crossref","first-page":"2287","DOI":"10.1056\/NEJMoa1001593","article-title":"In-center hemodialysis six times per week versus three times per week.","volume":"363","author":"Chertow","year":"2010","journal-title":"N Engl J Med"},{"key":"R30-20250504","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1001\/jama.298.11.1291","article-title":"Effect of frequent nocturnal hemodialysis vs conventional hemodialysis on left ventricular mass and quality of life: a randomized controlled trial.","volume":"298","author":"Culleton","year":"2007","journal-title":"JAMA"},{"key":"R31-20250504","doi-asserted-by":"crossref","first-page":"2235","DOI":"10.1046\/j.1523-1755.2002.00362.x","article-title":"Regression of left ventricular hypertrophy after conversion to nocturnal hemodialysis.","volume":"61","author":"Chan","year":"2002","journal-title":"Kidney Int"},{"key":"R32-20250504","doi-asserted-by":"crossref","first-page":"984","DOI":"10.1038\/ki.2009.291","article-title":"Survival and hospitalization among patients using nocturnal and short daily compared to conventional hemodialysis: a USRDS study.","volume":"76","author":"Johansen","year":"2009","journal-title":"Kidney Int"},{"key":"R33-20250504","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1681\/ASN.2011070674","article-title":"Survival with three-times weekly in-center nocturnal versus conventional hemodialysis.","volume":"23","author":"Lacson","year":"2012","journal-title":"J Am Soc Nephrol"},{"key":"R34-20250504","doi-asserted-by":"crossref","first-page":"696","DOI":"10.1681\/ASN.2011070676","article-title":"Intensive hemodialysis associates with improved survival compared with conventional hemodialysis.","volume":"23","author":"Nesrallah","year":"2012","journal-title":"J Am Soc Nephrol"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000033328","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T02:38:19Z","timestamp":1746326299000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000033328"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,24]]},"references-count":34,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000033328","relation":{},"ISSN":["0025-7974"],"issn-type":[{"type":"print","value":"0025-7974"}],"subject":[],"published":{"date-parts":[[2023,3,24]]}}}