{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T02:54:31Z","timestamp":1776740071027,"version":"3.51.2"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"14","license":[{"start":{"date-parts":[[2023,4,7]],"date-time":"2023-04-07T00:00:00Z","timestamp":1680825600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,4,7]]},"abstract":"<jats:p>The accuracy of percutaneous pedicle screw (PSS) placement in the lateral decubitus position has seldom been reported. This study aimed to retrospectively compare the accuracy of PPS placement with 3-dimensional (3D) fluoroscopy-based navigation in 2 cohorts of patients who underwent surgery in the lateral decubitus or prone positions at our single institute. A total of 265 consecutive patients underwent spinal surgery with PPS from T1 (thoracic 1) to S (sacrum) under the 3D fluoroscopy-based navigation system at our institute. Patients were divided into 2 groups based on their intraoperative patient positioning: lateral decubitus (Group L) or prone (Group P). A total of 1816 PPSs were placed from T1 to S, and 76 (4.18%) PPSs were assessed as deviated PPS. Twenty-one of 453 (4.64%) PPSs in Group L deviation and 55 of 1363 (4.04%) PPSs in Group P had deviated PPS, but with not significant difference (<jats:italic toggle=\"yes\">P<\/jats:italic> = .580). In Group L, although the PPS deviation rate was not significantly different between the upside and downside PPS, the downside PPS significantly deviated toward the lateral side compared with the upside PPS. The safety and efficacy of PPS insertion in the lateral decubitus position were similar to those in the conventional prone position.<\/jats:p>","DOI":"10.1097\/md.0000000000033451","type":"journal-article","created":{"date-parts":[[2023,4,7]],"date-time":"2023-04-07T13:17:57Z","timestamp":1680873477000},"page":"e33451","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":6,"title":["Accuracy of percutaneous pedicle screw placement with 3-dimensional fluoroscopy-based navigation: Lateral decubitus position versus prone position"],"prefix":"10.1097","volume":"102","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8604-659X","authenticated-orcid":false,"given":"Ryuichiro","family":"Okuda","sequence":"first","affiliation":[{"name":"Department of Orthopaedics Surgery, Kochi Health Sciences Center, Kochi, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hisanori","family":"Ikuma","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Kagawa Prefectural Central Hospital, Takamatsu, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomohiro","family":"Inoue","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Kagawa Prefectural Central Hospital, Takamatsu, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masataka","family":"Ueda","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Kagawa Prefectural Central Hospital, Takamatsu, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomohiko","family":"Hirose","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Kagawa Prefectural Central Hospital, Takamatsu, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazutoshi","family":"Otsuka","sequence":"additional","affiliation":[{"name":"Otsuka Orthopaedic Clinic, Takamatsu, Japan."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Keisuke","family":"Kawasaki","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Kagawa Prefectural Central Hospital, Takamatsu, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250504","doi-asserted-by":"crossref","first-page":"370","DOI":"10.1007\/s00586-009-1258-4","article-title":"Functional outcome of computer-assisted spinal pedicle screw placement: a systematic review and meta-analysis of 23 studies including 5,992 pedicle screws.","volume":"19","author":"Verma","year":"2010","journal-title":"Eur Spine J"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jocn.2020.07.012","article-title":"True accuracy of percutaneous pedicle screw placement in thoracic and lumbar spinal fixation with a CT-based navigation system: intraoperative and postoperative assessment of 763 percutaneous pedicle screws.","volume":"79","author":"Ouchida","year":"2020","journal-title":"J Clin Neurosci"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1186\/s12891-019-2992-3","article-title":"Comparison of radiological changes after single- position versus dual-position for lateral interbody fusion and pedicle screw fixation.","volume":"20","author":"Hiyama","year":"2019","journal-title":"BMC Musculoskelet Disord"},{"key":"R4-20250504","doi-asserted-by":"crossref","first-page":"1277","DOI":"10.1007\/s00586-020-06388-6","article-title":"Simultaneous single-position lateral interbody fusion and percutaneous pedicle screw fixation using O-arm-based navigation reduces the occupancy time of the operating room.","volume":"29","author":"Ouchida","year":"2020","journal-title":"Eur Spine J"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1186\/s13018-019-1354-z","article-title":"The analysis of percutaneous pedicle screw technique with guide wire-less in lateral decubitus position following extreme lateral interbody fusion.","volume":"14","author":"Hiyama","year":"2019","journal-title":"J Orthop Surg Res"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1097\/BRS.0000000000002330","article-title":"MIS single-position lateral and oblique lateral lumbar interbody fusion and bilateral pedicle screw fixation: feasibility and perioperative results.","volume":"43","author":"Blizzard","year":"2018","journal-title":"Spine. (Phila Pa 1976)"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1097\/BRS.0b013e3181cbfd09","article-title":"Clinical accuracy of computer-assisted two-dimensional fluoroscopy for the percutaneous placement of lumbosacral pedicle screws.","volume":"36","author":"Ravi","year":"2010","journal-title":"Spine"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"S361","DOI":"10.1097\/BRS.0b013e318202308b","article-title":"Biomechanical analysis and review of lateral lumbar fusion constructs.","volume":"35","author":"Cappuccino","year":"2010","journal-title":"Spine"},{"key":"R9-20250504","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1186\/s41016-019-0154-y","article-title":"Accuracy of pedicle screw placement in the thoracic and lumbosacral spines using O-arm-based navigation versus conventional freehand technique.","volume":"5","author":"Jing","year":"2019","journal-title":"Chin Neurosurg J"},{"key":"R10-20250504","doi-asserted-by":"crossref","first-page":"875","DOI":"10.1007\/s00586-010-1683-4","article-title":"Computer tomography assessment of pedicle screw placement in lumbar and sacral spine: comparison between free-hand and O-arm based navigation techniques.","volume":"20","author":"Silbermann","year":"2011","journal-title":"Eur Spine J"},{"key":"R11-20250504","doi-asserted-by":"crossref","first-page":"E7","DOI":"10.3171\/2014.1.FOCUS13499","article-title":"Thoracolumbar instrumentation with CT-guided navigation (O-arm) in 270 consecutive patients: accuracy rates and lessons learned.","volume":"36","author":"Rivkin","year":"2014","journal-title":"Neurosurg Focus"},{"key":"R12-20250504","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1007\/s00586-011-2011-3","article-title":"Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques.","volume":"21","author":"Gelalis","year":"2012","journal-title":"Eur Spine J"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"628","DOI":"10.3171\/2016.10.SPINE16373","article-title":"Clinical outcomes following spinal fusion using an intraoperative computed tomographic 3D imaging system.","volume":"26","author":"Xiao","year":"2017","journal-title":"J Neurosurg Spine"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"340","DOI":"10.31616\/asj.2020.0089","article-title":"Treatment of thoracolumbar spinal fracture accompanied by diffuse idiopathic skeletal hyperostosis using transdiscal screws for diffuse idiopathic skeletal hyperostosis: preliminary results.","volume":"15","author":"Ikuma","year":"2021","journal-title":"Asian Spine J"},{"key":"R15-20250504","doi-asserted-by":"crossref","first-page":"103008","DOI":"10.1016\/j.otsr.2021.103008","article-title":"Spinopelvic fixation with retention of external fixation in a lateral position for unstable pelvic fracture.","volume":"107","author":"Yamamoto","year":"2021","journal-title":"Orthop Traumatol Surg Res"},{"key":"R16-20250504","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1016\/j.spinee.2016.10.019","article-title":"Are pedicle screw perforation rates influenced by distance from the reference frame in multilevel registration using a computed tomography-based navigation system in the setting of scoliosis?","volume":"17","author":"Uehara","year":"2017","journal-title":"Spine J"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000033451","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T02:25:07Z","timestamp":1746325507000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000033451"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4,7]]},"references-count":16,"journal-issue":{"issue":"14","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000033451","relation":{},"ISSN":["0025-7974"],"issn-type":[{"value":"0025-7974","type":"print"}],"subject":[],"published":{"date-parts":[[2023,4,7]]}}}