{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,26]],"date-time":"2026-04-26T06:23:28Z","timestamp":1777184608140,"version":"3.51.4"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"26","license":[{"start":{"date-parts":[[2023,6,30]],"date-time":"2023-06-30T00:00:00Z","timestamp":1688083200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,6,30]]},"abstract":"<jats:p>Using the finite element analysis method to help us better understand the biomechanical changes of the spine after surgery and the changes in the stress distribution around the screw implantation area. The finite element model of L1 vertebral compression fracture was constructed by using a large number of finite element programs. On the fracture model, 2 kinds of internal fixation devices are set up, namely: the first type of 4 screws across the injured vertebra through the adjacent upper and lower vertebrae\u2005+\u2005transverse connector; the second type of 4 screws crosses the injured vertebra through the adjacent upper and lower vertebrae\u2005+\u2005non-transverse connector. To study the distribution of the maximum displacement and von Mises stress of the intramedullary pedicle screws and rods of the 2 types of internal fixation devices after implantation in the spine under certain loading conditions. In traditional open pedicle screw fixation, the maximum stress in the pedicle screw fixation system in the direction of 3D movement is higher than in percutaneous pedicle screw fixation. There is no significant difference in the Von Mises stress of the pedicle screw between the 2 procedures when the spine performs flexion-extension and lateral flexion activities. When the spine is rotating axially, the Von Mises stress of the pedicle screw in conventional open surgery is significantly less than that of the screw in percutaneous pedicle screw fixation. Traditional open internal fixation produces stress peaks of 891.7\u2009MPa and 886.34\u2009MPa at the transverse joint during axial rotation. Only when the spine is rotating in the axial direction, the maximum displacement of traditional open pedicle screw fixation is smaller than that of percutaneous pedicle screw fixation. There is no significant difference in the maximum displacement between the 2 procedures when the spine is moving in other directions. Traditional open pedicle screw fixation can strengthen the stability of the spine in the direction of axial rotation, and can also be greater to reduce the maximum stress of the pedicle screw axial rotation, so the clinical treatment of unstable fractures of the thoracolumbar spine instability is of great significance.<\/jats:p>","DOI":"10.1097\/md.0000000000034145","type":"journal-article","created":{"date-parts":[[2023,6,30]],"date-time":"2023-06-30T18:02:54Z","timestamp":1688148174000},"page":"e34145","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Finite element analysis of minimally invasive nail placement and traditional nail placement in the treatment of lumbar 1 vertebral compression fracture"],"prefix":"10.1097","volume":"102","author":[{"given":"Chunbo","family":"Huang","sequence":"first","affiliation":[{"name":"Department of Orthopaedics, Hebei North University, Zhangjiakou, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chunling","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, the First Affiliated Hospital of Hebei North University, Zhangjiakou, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Feng","family":"Su","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, the First Affiliated Hospital of Hebei North University, Zhangjiakou, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Liu","family":"Su","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, the First Affiliated Hospital of Hebei North University, Zhangjiakou, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pengpeng","family":"Ma","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, the First Affiliated Hospital of Hebei North University, Zhangjiakou, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhiguo","family":"Zong","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, the First Affiliated Hospital of Hebei North University, Zhangjiakou, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xin","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, the First Affiliated Hospital of Hebei North University, Zhangjiakou, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, the First Affiliated Hospital of Hebei North University, Zhangjiakou, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ming","family":"Cai","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, the First Affiliated Hospital of Hebei North University, Zhangjiakou, China."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250504","first-page":"3","article-title":"Spinal fractures resulting from traumatic injuries.","volume":"13","author":"Heidari","year":"2010","journal-title":"Chin J Traumatol"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1515\/med-2015-0071","article-title":"Comparative study of the clinical effect and safety of anterior surgical approach and posterior surgical approach in the treatment of thoracolumbar spinal fracture.","volume":"10","author":"Dengfeng","year":"2015","journal-title":"Open Med"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"e1109","DOI":"10.1016\/j.wneu.2019.05.077","article-title":"Finite element analysis of short- versus long-segment posterior fixation for thoracolumbar burst fracture.","volume":"128","author":"Basaran","year":"2019","journal-title":"World Neurosurg"},{"key":"R4-20250504","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1016\/j.spinee.2012.10.041","article-title":"Management of thoracolumbar spine fractures.","volume":"14","author":"Wood","year":"2014","journal-title":"Spine J"},{"key":"R5-20250504","first-page":"5","article-title":"Individualized unilateral nailing combined with bone grafting for thoracolumbar burst fracture.","volume":"27","author":"Li","year":"2019","journal-title":"Chin J Orthop Surg"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1097\/01.brs.0000256473.49791.f4","article-title":"Comparison of one-level posterior lumbar interbody fusion performed with a minimally invasive approach or a traditional open approach.","volume":"32","author":"Park","year":"2007","journal-title":"Spine"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1097\/NCM.0b013e3182529c05","article-title":"Effect of minimally invasive technique on return to work and narcotic use following transforaminal lumbar inter-body fusion: a review.","volume":"17","author":"Parker","year":"2012","journal-title":"Prof Case Manag"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1097\/BSD.0b013e31825d68ac","article-title":"Comparison of the clinical outcome in overweight or obese patients after minimally invasive versus open transforaminal lumbar interbody fusion.","volume":"27","author":"Wang","year":"2014","journal-title":"J Spinal Disord Tech"},{"key":"R9-20250504","doi-asserted-by":"crossref","first-page":"2265","DOI":"10.1007\/s00586-012-2281-4","article-title":"Clinical and radiological outcomes of open versus minimally invasive transforaminal lumbar interbody fusion.","volume":"21","author":"Lee","year":"2012","journal-title":"Eur Spine J"},{"key":"R10-20250504","doi-asserted-by":"crossref","first-page":"1171","DOI":"10.1007\/s00586-011-2114-x","article-title":"Mid-term clinical results of minimally invasive decompression and posterolateral fusion with percutaneous pedicle screws versus conventional approach for degenerative spondylolisthesis with spinal stenosis.","volume":"21","author":"Kotani","year":"2012","journal-title":"Eur Spine J"},{"key":"R11-20250504","first-page":"E2","article-title":"Flexion-distraction injuries of the thoracolumbar spine: open fusion versus percutaneous pedicle screw fixation.","volume":"35","author":"Grossbach","year":"2013","journal-title":"Am Assoc Neurol Surg"},{"key":"R12-20250504","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1080\/10255842.2019.1709173","article-title":"Individualized prediction of pedicle screw fixation strength with a finite element model.","volume":"23","author":"Widmer","year":"2020","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1016\/j.clinbiomech.2007.10.001","article-title":"The relation between the instantaneous center of rotation and facet joint forces \u2013 a finite element analysis.","volume":"23","author":"Schmidt","year":"2008","journal-title":"Clin Biomech"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1115\/1.2835106","article-title":"Study on effect of graded facetectomy on change in lumbar motion segment torsional flexibility.","volume":"121","author":"Natarajan","year":"1999","journal-title":"J Biomech Eng"},{"key":"R15-20250504","doi-asserted-by":"crossref","first-page":"1256","DOI":"10.1097\/00007632-198911000-00020","article-title":"Three-D moments of the whole lumbar spoie and lumbosacral joint.","volume":"14","author":"Yamamoto","year":"1989","journal-title":"Spine"},{"key":"R16-20250504","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1186\/1475-925X-11-31","article-title":"Biomechanical evaluation of three surgical scenarios of posterior lumbar interbody fusion by finite element analysis.","volume":"11","author":"Xiao","year":"2012","journal-title":"Biomed Eng Online"},{"key":"R17-20250504","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1097\/01.brs.0000209251.65417.16","article-title":"Combined anterior plus posterior stabilization versus posterior short-segment instrumentation and fusion for mid-lumbar (L2\u2013L4) burst fractures.","volume":"31","author":"Korovessis","year":"2006","journal-title":"Spine"},{"key":"R18-20250504","doi-asserted-by":"crossref","first-page":"72","DOI":"10.4103\/0019-5413.143914","article-title":"Management of thoracolumbar spine trauma an overvie.","volume":"49","author":"Rajasekaran","year":"2015","journal-title":"Indian J Orthop"},{"key":"R20-20250504","first-page":"3","article-title":"Comparison of the efficacy of percutaneous and open pedicle screw instrumentation in thoracolumbar fractures without nerve injury.","volume":"2","author":"Chunxin","year":"2017","journal-title":"Syst Med"},{"key":"R21-20250504","first-page":"5","article-title":"Efficacy of percutaneous pedicle screw fixation in the treatment of thoracolumbar fracture.","volume":"4","author":"Peng","year":"2019","journal-title":"J Orthop Clin Res"},{"key":"R22-20250504","doi-asserted-by":"crossref","first-page":"1485","DOI":"10.1016\/j.spinee.2013.05.022","article-title":"Effectiveness of cross-linking posterior segmental instrumentation in adolescent idiopathic scoliosis: a 2-year follow-up comparative study.","volume":"13","author":"Dhawale","year":"2013","journal-title":"Spine J Off J N Am Spine Soc"},{"key":"R23-20250504","first-page":"4","article-title":"Effect of transverse linking on internal fixation of single-segment short pedicle screws.","volume":"32","author":"Wu","year":"2010","journal-title":"J Ningxia Med Univ"},{"key":"R24-20250504","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3171\/2014.6.SPINE13751","article-title":"Biomechanical analysis of anterior versus posterior instrumentation following a thoracolumbar corpectomy: laboratory investigation.","volume":"21","author":"Viljoen","year":"2014","journal-title":"J Neurosurg Spine"},{"key":"R25-20250504","first-page":"4","article-title":"Domestic and international studies on advanced titanium standards for surgical implants.","volume":"5","author":"Ma","year":"2016","journal-title":"World Nonferr Met"},{"key":"R26-20250504","first-page":"27","article-title":"Current status of the development and application of new medical titanium alloy materials.","volume":"53","author":"Yu","year":"2017","journal-title":"J Met"},{"key":"R27-20250504","first-page":"5","article-title":"Comparison of the efficacy of percutaneous and open pedicle screw internal fixation in the treatment of thoracolumbar type A fractures without nerve injury.","volume":"25","author":"Su","year":"2019","journal-title":"J Pract Orthop"},{"key":"R28-20250504","first-page":"028","article-title":"Comparative study of open and percutaneous pedicle screw internal fixation in the treatment of simple thoracolumbar vertebral fracture.","volume":"005","author":"Hu","year":"2022","journal-title":"J Pract Orthop"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000034145","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T02:08:54Z","timestamp":1746324534000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000034145"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,30]]},"references-count":27,"journal-issue":{"issue":"26","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000034145","relation":{},"ISSN":["0025-7974"],"issn-type":[{"value":"0025-7974","type":"print"}],"subject":[],"published":{"date-parts":[[2023,6,30]]}}}