{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T00:05:19Z","timestamp":1747181119728,"version":"3.40.5"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"11","license":[{"start":{"date-parts":[[2024,3,15]],"date-time":"2024-03-15T00:00:00Z","timestamp":1710460800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,3,15]]},"abstract":"<jats:p>The study aimed to determine the optimal entry points and trajectories for posterior subaxial cervical pedicle screw (CPS) fixation. Computed tomography (CT) and Mimics software were used to evaluate the subaxial cervical pedicle in 42 cervical spine CT scans. The width of the cervical pedicle was measured and compared at medial angulations of 30\u00b0, 35\u00b0, 40\u00b0, 45\u00b0, 50\u00b0, 55\u00b0, and 60\u00b0 relative to the midline sagittal plane. Based on an observational examination of the positions of all cervical 3-dimensional models and screws, the proposed entry point for C3\u20137 CPS was analyzed. Although the variations in C3\u20136 pedicle width (PW) among 45\u00b0, 50\u00b0, and 55\u00b0 were not statistically significant, they were significantly larger than the differences among 30\u00b0, 35\u00b0, 40\u00b0, and 60\u00b0 angles (<jats:italic toggle=\"yes\">P\u2005&lt;\u2005<\/jats:italic>.05). The differences in C7 PW between the 30\u00b0, 35\u00b0, 40\u00b0, and 45\u00b0 angles were not statistically different even though the 30\u00b0, 35\u00b0, 40\u00b0, and 45\u00b0 angles were significantly bigger. (<jats:italic toggle=\"yes\">P\u2005&lt;\u2005<\/jats:italic>.05). The proposed entry point for C3\u20137 CPS was below the junction of the lateral and lower borders of the superior articular process joint surface. The entry point for C3\u20137 levels was below the junction of the lateral and lower borders of the superior articular process joint surface. The optimal medial angulation for the posterior C3\u20136 CPS was 45\u00b0\u201355\u00b0 and that for the posterior C7 CPS was 30\u00b0\u201345\u00b0. The sagittal angle of the posterior C3\u20137 CPS was parallel to the corresponding upper endplate.<\/jats:p>","DOI":"10.1097\/md.0000000000034646","type":"journal-article","created":{"date-parts":[[2024,3,15]],"date-time":"2024-03-15T21:01:07Z","timestamp":1710536467000},"page":"e34646","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Research into the anatomy of the subaxial cervical pedicle for ensuring screw insertion safety"],"prefix":"10.1097","volume":"103","author":[{"given":"Wei-Xin","family":"Dong","sequence":"first","affiliation":[{"name":"Department of Spinal Surgery, Ningbo No.6 Hospital, Ningbo, Zhejiang Province, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2423-9513","authenticated-orcid":false,"given":"Yong","family":"Hu","sequence":"additional","affiliation":[{"name":"Department of Spinal Surgery, Ningbo No.6 Hospital, Ningbo, Zhejiang Province, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhen-Shan","family":"Yuan","sequence":"additional","affiliation":[{"name":"Department of Spinal Surgery, Ningbo No.6 Hospital, Ningbo, Zhejiang Province, China."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250503","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1097\/00002517-199407010-00003","article-title":"Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report.","volume":"7","author":"Abumi","year":"1994","journal-title":"J Spinal Disord"},{"key":"R2-20250503","doi-asserted-by":"crossref","first-page":"962","DOI":"10.1097\/00007632-200004150-00011","article-title":"Complications of pedicle screw fixation in reconstructive surgery of the cervical spine.","volume":"25","author":"Abumi","year":"2000","journal-title":"Spine"},{"key":"R3-20250503","doi-asserted-by":"crossref","first-page":"488","DOI":"10.3171\/spi.2006.5.6.488","article-title":"Cervical pedicle screw fixation in 100 cases of unstable cervical injuries: pedicle axis views obtained using fluoroscopy.","volume":"5","author":"Yukawa","year":"2006","journal-title":"J Neurosurg Spine"},{"key":"R4-20250503","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1097\/BSD.0b013e31824e65f4","article-title":"Pedicle screws can be 4 times stronger than lateral mass screws for insertion in the midcervical spine: a biomechanical study on strength of fixation.","volume":"27","author":"Ito","year":"2014","journal-title":"J Spinal Disord Tech"},{"key":"R5-20250503","doi-asserted-by":"crossref","first-page":"1217","DOI":"10.1080\/03007995.2017.1385450","article-title":"A review of translational medicine. The future paradigm: how can we connect the orthopedic dots better?.","volume":"34","author":"Mediouni","year":"2018","journal-title":"Curr Med Res Opin"},{"key":"R6-20250503","doi-asserted-by":"crossref","first-page":"2166","DOI":"10.1007\/s00586-014-3470-0","article-title":"A multicenter study on accuracy and complications of freehand placement of cervical pedicle screws under lateral fluoroscopy in different pathological conditions: CT-based evaluation of more than 1,000 screws.","volume":"23","author":"Hojo","year":"2014","journal-title":"Eur Spine J"},{"key":"R7-20250503","doi-asserted-by":"crossref","first-page":"390","DOI":"10.4103\/jcvjs.JCVJS_92_17","article-title":"Easy method to simplify \u201cfreehand\u201d subaxial cervical pedicle screw insertion.","volume":"8","author":"Burcev","year":"2017","journal-title":"J Craniovertebr Junction Spine"},{"key":"R8-20250503","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1007\/s00586-010-1655-8","article-title":"Optimal entry points and trajectories for cervical pedicle screw placement into subaxial cervical vertebrae.","volume":"20","author":"Lee","year":"2011","journal-title":"Eur Spine J"},{"key":"R9-20250503","doi-asserted-by":"crossref","first-page":"262","DOI":"10.21037\/jss.2020.03.07","article-title":"Anatomic techniques for cervical pedicle screw placement.","volume":"6","author":"Tan","year":"2020","journal-title":"J Spine Surg"},{"key":"R10-20250503","doi-asserted-by":"crossref","first-page":"2510","DOI":"10.1097\/01.brs.0000144404.68486.85","article-title":"Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle.","volume":"29","author":"Sakamoto","year":"2004","journal-title":"Spine"},{"key":"R11-20250503","doi-asserted-by":"crossref","first-page":"472","DOI":"10.3171\/spi.2006.4.6.472","article-title":"Anatomical considerations for cervical pedicle screw insertion: the use of multiplanar computerized tomography reconstruction measurements.","volume":"4","author":"Chazono","year":"2006","journal-title":"J Neurosurg Spine"},{"key":"R12-20250503","doi-asserted-by":"crossref","first-page":"2456","DOI":"10.1097\/00007632-200111150-00012","article-title":"Accuracy of cervical pedicle screw placement using the funnel technique.","volume":"26","author":"Karaikovic","year":"2001","journal-title":"Spine"},{"key":"R13-20250503","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1097\/00002517-199407030-00004","article-title":"Transpedicular screw fixation of articular mass fracture-separation: results of an anatomical study and operative technique.","volume":"7","author":"Jeanneret","year":"1994","journal-title":"J Spinal Disord"},{"key":"R14-20250503","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1097\/00007632-199703010-00005","article-title":"Morphologic characteristics of human cervical pedicles.","volume":"22","author":"Karaikovic","year":"1997","journal-title":"Spine"},{"key":"R15-20250503","doi-asserted-by":"crossref","first-page":"729","DOI":"10.1016\/j.spinee.2009.04.021","article-title":"Anatomical considerations for cervical pedicle screw insertion: the use of multiplanar computerized tomography measurements in 122 consecutive clinical cases.","volume":"9","author":"Onibokun","year":"2009","journal-title":"Spine J"},{"key":"R16-20250503","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1016\/j.spinee.2016.11.011","article-title":"Perforations and angulations of 324 cervical medial cortical pedicle screws: a possible guide to avoid lateral perforations with use of pedicle screws in lower cervical spine.","volume":"17","author":"Mahesh","year":"2017","journal-title":"Spine J"},{"key":"R17-20250503","doi-asserted-by":"crossref","first-page":"1457","DOI":"10.1007\/s00586-008-0756-0","article-title":"The contralateral lamina: a reliable guide in subaxial, cervical pedicle screw placement.","volume":"17","author":"Hacker","year":"2008","journal-title":"Eur Spine J"},{"key":"R18-20250503","doi-asserted-by":"crossref","first-page":"901","DOI":"10.1007\/s00402-013-1752-3","article-title":"Computed tomography assessment of lateral pedicle wall perforation by free-hand subaxial cervical pedicle screw placement.","volume":"133","author":"Wang","year":"2013","journal-title":"Arch Orthop Trauma Surg"},{"key":"R19-20250503","doi-asserted-by":"crossref","first-page":"2280","DOI":"10.1097\/01.brs.0000182275.31425.cd","article-title":"Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws.","volume":"30","author":"Richter","year":"2005","journal-title":"Spine"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000034646","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T00:04:21Z","timestamp":1746317061000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000034646"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,15]]},"references-count":19,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000034646","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"type":"print","value":"0025-7974"},{"type":"electronic","value":"1536-5964"}],"subject":[],"published":{"date-parts":[[2024,3,15]]}}}