{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T18:45:54Z","timestamp":1792089954791,"version":"4.4.0"},"reference-count":39,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"36","license":[{"start":{"date-parts":[[2023,9,8]],"date-time":"2023-09-08T00:00:00Z","timestamp":1694131200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,9,8]]},"abstract":"<jats:p>Metacarpal neck fracture is one of the most common types of hand fractures; the literature suggests that applying a bone plate on the dorsal side provides higher fixation strength than that provided by other fixation methods. However, bone plate fixation on the dorsal side may result in postoperative tendon adhesion. So far, no studies have investigated the fixation of metacarpal neck fractures on the volar side by using a bone plate. The objective of this study was to investigate the differences in the fixation results between bone plate fixation on the dorsal side and bone plate fixation on the volar side of the metacarpal in the case of a metacarpal neck fracture. A saw blade was used to create a transverse metacarpal neck fracture on 14 artificial metacarpal bone specimens. The specimens were divided into 2 groups depending on the fixation method: a volar locking plate (VLP) group and a dorsal locking plate (DLP) group. All specimens were subjected to a cantilever bending test on a material testing system, and a force\u2013displacement curve was used to measure the yield force and stiffness, which served as an indicator of the fixation ability of the 2 fracture fixation methods. For the experimental results, the Mann\u2013Whitney <jats:italic toggle=\"yes\">U<\/jats:italic> test was used to compare the fixation abilities of the 2 fixation methods. In terms of yield force, the DLP group (266.9\u2009\u00b1\u200968.3\u2009N) scored significantly higher than the VLP group (32.6\u2009\u00b1\u20092.7\u2009N) (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; .05); expressed in terms of median, the DLP group scored 8.2 times higher than the VLP group. Similarly, in terms of stiffness, the DLP group (69.0\u2009\u00b1\u200913.4\u2009N\/mm, median <jats:bold>\u00b1<\/jats:bold> interquartile range) scored significantly higher than the VLP group (12.9\u2009\u00b1\u20091.4\u2009N\/mm) (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; .05); expressed in terms of median, the DLP group scored 5.3 times higher than the VLP group. The fixation strength of volar bone plates is only about one-third of that of dorsal bone plates.<\/jats:p>","DOI":"10.1097\/md.0000000000034981","type":"journal-article","created":{"date-parts":[[2023,9,8]],"date-time":"2023-09-08T14:10:53Z","timestamp":1694182253000},"page":"e34981","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["Biomechanical study of the fixation ability of the dorsal and volar locking plate for transverse metacarpal neck fractures"],"prefix":"10.1097","volume":"102","author":[{"given":"Tsung-Yu","family":"Ho","sequence":"first","affiliation":[{"name":"School of Medicine, China Medical University, Taichung, Taiwan"},{"name":"Department of Orthopedic Surgery, China Medical University Hospital, Taichung, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cheng-En","family":"Hsu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Taichung Veterans General Hospital, Taichung, Taiwan"},{"name":"Sports Recreation and Health Management Continuing Studies-Bachelor\u2019s Degree Completion Program, Tunghai University, Taichung, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei-Chih","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, China Medical University Hospital, Taichung, Taiwan"},{"name":"Department of Orthopedic Surgery, China Medical University Hsinchu Hospital, Hsinchu, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yen-Nien","family":"Ting","sequence":"additional","affiliation":[{"name":"3D Printing Medical Research Center, China Medical University Hospital, Taichung, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ming-Tzu","family":"Tsai","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Hungkuang University, Taichung, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yung-Cheng","family":"Chiu","sequence":"additional","affiliation":[{"name":"School of Medicine, China Medical University, Taichung, Taiwan"},{"name":"Department of Orthopedic Surgery, China Medical University Hospital, Taichung, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jui-Ting","family":"Hsu","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, China Medical University, Taichung, Taiwan"},{"name":"School of Dentistry, China Medical University, Taichung, Taiwan."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250504","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1177\/1558944718798854","article-title":"A comparison of locking plates and intramedullary pinning for fixation of metacarpal shaft fractures.","volume":"14","author":"Dreyfuss","year":"2019","journal-title":"Hand"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1055\/s-0042-1751077","article-title":"A biomechanical comparison of fixation techniques in metacarpal shaft fractures.","volume":"12","author":"Albanese","year":"2023","journal-title":"J Wrist Surg"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"187","DOI":"10.11604\/pamj.2014.18.187.3347","article-title":"Fractures of the neck of the fifth metacarpal bone, treated by percutaneous intramedullary nailing: surgical technique, radiological and clinical results study (28 cases).","volume":"18","author":"Boussakri","year":"2014","journal-title":"Pan Afr Med J"},{"key":"R4-20250504","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1016\/j.otsr.2010.02.009","article-title":"Fifth metacarpal neck fracture fixation: locking plate versus K-wire?","volume":"96","author":"Facca","year":"2010","journal-title":"Orthop Traumatol Surg Res"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"1068","DOI":"10.1016\/j.jhsa.2006.06.006","article-title":"Incidence and demographics of hand fractures in British Columbia, Canada: a population-based study.","volume":"31","author":"Feehan","year":"2006","journal-title":"J Hand Surg Am"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1177\/17531934221079182","article-title":"Palmar approach for fixation of metacarpal fractures.","volume":"47","author":"Nazerani","year":"2022","journal-title":"J Hand Surg Eur Vol"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1007\/s11552-013-9562-1","article-title":"Metacarpal fractures: treatment and complications.","volume":"9","author":"Kollitz","year":"2014","journal-title":"Hand"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"1362","DOI":"10.1016\/j.jhsa.2008.04.010","article-title":"Comparison of 2 methods of immobilization of fifth metacarpal neck fractures: a prospective randomized study.","volume":"33","author":"Hofmeister","year":"2008","journal-title":"J Hand Surg Am"},{"key":"R9-20250504","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/j.cjtee.2016.06.009","article-title":"Biomechanical analysis of tension band wiring (TBW) of transverse fractures of patella.","volume":"19","author":"Ali","year":"2016","journal-title":"Chin J Traumatol"},{"key":"R10-20250504","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1016\/J.JHSB.2005.09.013","article-title":"External fixation of closed metacarpal and phalangeal fractures of digits. A prospective study of one hundred consecutive patients.","volume":"31","author":"Margi\u0107","year":"2006","journal-title":"J Hand Surg Br"},{"key":"R11-20250504","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1016\/S0363-5023(85)80067-8","article-title":"Comparison of internal fixation techniques in metacarpal fractures.","volume":"10","author":"Black","year":"1985","journal-title":"J Hand Surg Am"},{"key":"R12-20250504","first-page":"e9442","article-title":"Management of fifth metacarpal neck fracture (boxer\u2019s fracture): a literature review.","volume":"12","author":"Hussain","year":"2020","journal-title":"Cureus"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"e32933","DOI":"10.5812\/atr.32933","article-title":"Metacarpal neck fractures: a review of surgical indications and techniques.","volume":"5","author":"Padegimas","year":"2016","journal-title":"Arch Trauma Res"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1016\/j.injury.2011.10.036","article-title":"Fractures of the neck of the fifth metacarpal bone. Medium-term results in 28 cases treated by percutaneous transverse pinning.","volume":"43","author":"Potenza","year":"2012","journal-title":"Injury"},{"key":"R15-20250504","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1111\/os.12195","article-title":"Fixation of metacarpal shaft fractures: biomechanical comparison of intramedullary nail crossed K-wires and plate-screw constructs.","volume":"7","author":"Curtis","year":"2015","journal-title":"Orthop Surg"},{"key":"R16-20250504","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1186\/s13018-021-02575-3","article-title":"Bone plate fixation ability on the dorsal and lateral sides of a metacarpal shaft transverse fracture.","volume":"16","author":"Chiu","year":"2021","journal-title":"J Orthop Surg Res"},{"key":"R17-20250504","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1186\/s13018-018-0890-2","article-title":"New fixation approach for transverse metacarpal neck fracture: a biomechanical study.","volume":"13","author":"Chiu","year":"2018","journal-title":"J Orthop Surg Res"},{"key":"R18-20250504","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1186\/s13018-021-02627-8","article-title":"The curative effect analysis of a modified Kirschner wires and locking plate internal fixation method for the fifth metacarpal neck fracture.","volume":"16","author":"Gu","year":"2021","journal-title":"J Orthop Surg Res"},{"key":"R19-20250504","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1007\/s11552-015-9744-0","article-title":"Fixation for metacarpal neck fracture: a biomechanical study.","volume":"10","author":"Malasitt","year":"2015","journal-title":"Hand"},{"key":"R20-20250504","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1007\/s00402-015-2164-3","article-title":"Comparison of treatment of oblique and spiral metacarpal and phalangeal fractures with mini plate plus screw or screw only.","volume":"135","author":"Ba\u015far","year":"2015","journal-title":"Arch Orthop Trauma Surg"},{"key":"R21-20250504","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1016\/S0894-1130(03)80009-1","article-title":"Management of metacarpal fractures.","volume":"16","author":"McNemar","year":"2003","journal-title":"J Hand Ther"},{"key":"R22-20250504","doi-asserted-by":"crossref","first-page":"648787","DOI":"10.1155\/2014\/648787","article-title":"Biomechanical analysis of the efficacy of locking plates during cyclic loading in metacarpal fractures.","volume":"2014","author":"Doht","year":"2014","journal-title":"ScientificWorldJournal"},{"key":"R23-20250504","doi-asserted-by":"crossref","first-page":"1692","DOI":"10.1100\/2011\/465371","article-title":"Experimental fracture model versus osteotomy model in metacarpal bone plate fixation.","volume":"11","author":"Ochman","year":"2011","journal-title":"ScientificWorldJournal"},{"key":"R24-20250504","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1007\/s11552-013-9544-3","article-title":"Plating of metacarpal fractures with locked or nonlocked screws, a biomechanical study: how many cortices are really necessary?","volume":"8","author":"Barr","year":"2013","journal-title":"Hand (N Y)"},{"key":"R25-20250504","doi-asserted-by":"crossref","first-page":"e6926","DOI":"10.1097\/MD.0000000000006926","article-title":"A biomechanical analysis of plate fixation using unicortical and bicortical screws in transverse metacarpal fracture models subjected to 4-point bending and dynamical bending test.","volume":"96","author":"Liodaki","year":"2017","journal-title":"Medicine (Baltim)"},{"key":"R27-20250504","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1007\/s40846-022-00742-3","article-title":"Insertion speed affects the initial stability of dental implants.","volume":"42","author":"Hsu","year":"2022","journal-title":"J Med Biol Eng"},{"key":"R28-20250504","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1007\/s40846-022-00737-0","article-title":"The effects of diameter, length and insertion method on the stability of orthodontic miniscrew.","volume":"42","author":"Yu","year":"2022","journal-title":"J Med Biol Eng"},{"key":"R29-20250504","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1053\/jhsu.2001.24145","article-title":"Mechanical testing of bioresorbable implants for use in metacarpal fracture fixation.","volume":"26","author":"Bozic","year":"2001","journal-title":"J Hand Surg Am"},{"key":"R30-20250504","doi-asserted-by":"crossref","first-page":"1851","DOI":"10.1016\/j.jhsa.2009.07.005","article-title":"Biomechanical comparison of double-row locking plates versus single-and double-row non-locking plates in a comminuted metacarpal fracture model.","volume":"34","author":"Gajendran","year":"2009","journal-title":"J Hand Surg Am"},{"key":"R31-20250504","doi-asserted-by":"crossref","first-page":"e159","DOI":"10.1016\/j.jhsa.2017.01.003","article-title":"Comparison of 2-dimensional and 3-dimensional metacarpal fracture plating constructs under cyclic loading.","volume":"42","author":"Tannenbaum","year":"2017","journal-title":"J Hand Surg Am"},{"key":"R32-20250504","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1186\/s12891-021-04276-8","article-title":"Effect of a figure-of-eight cerclage wire with two Kirschner wires on fixation strength for transverse metacarpal shaft fractures: an in vitro study with artificial bone.","volume":"22","author":"Chiu","year":"2021","journal-title":"BMC Musculoskelet Disord"},{"key":"R33-20250504","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1016\/j.jhsa.2007.11.001","article-title":"Comparison of metacarpal plating methods.","volume":"33","author":"Sohn","year":"2008","journal-title":"J Hand Surg Am"},{"key":"R34-20250504","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1142\/S0218810415500148","article-title":"Surgical outcomes of fifth metacarpal neck fractures \u2013 a comparative analysis of dorsal plating versus tension band wiring.","volume":"20","author":"Wong","year":"2015","journal-title":"Hand Surg"},{"key":"R35-20250504","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1097\/00003086-198701000-00009","article-title":"Use of a minicondylar plate for metacarpal and phalangeal periarticular injuries.","volume":"214","author":"B\u00fcchler","year":"1987","journal-title":"Clin Orthop Relat Res"},{"key":"R36-20250504","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1007\/s00068-015-0507-y","article-title":"Open reduction and internal fixation versus percutaneous transverse Kirschner wire fixation for single, closed second to fifth metacarpal shaft fractures: a systematic review.","volume":"42","author":"Greeven","year":"2016","journal-title":"Eur J Trauma Emerg Surg"},{"key":"R37-20250504","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1007\/s40846-022-00713-8","article-title":"Biomechanical analysis of new cross locking plates for metacarpal neck fracture.","volume":"42","author":"Yang","year":"2022","journal-title":"J Med Biol Eng"},{"key":"R38-20250504","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1177\/1558944717731859","article-title":"Headless screw fixation of metacarpal neck fractures: a mechanical comparative analysis.","volume":"14","author":"Jones","year":"2019","journal-title":"Hand"},{"key":"R39-20250504","doi-asserted-by":"crossref","first-page":"1299","DOI":"10.1016\/j.jhsa.2007.07.020","article-title":"Volar plating for intra-articular fracture of the base of the proximal phalanx.","volume":"32","author":"Hattori","year":"2007","journal-title":"J Hand Surg Am"},{"key":"R40-20250504","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1177\/1558944718813730","article-title":"The effect of age on fracture healing time in metacarpal fractures.","volume":"15","author":"Wollstein","year":"2020","journal-title":"Hand"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000034981","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T02:29:01Z","timestamp":1746325741000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000034981"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,8]]},"references-count":39,"journal-issue":{"issue":"36","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000034981","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9,8]]}}}