{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T00:06:39Z","timestamp":1747181199439,"version":"3.40.5"},"reference-count":28,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"42","license":[{"start":{"date-parts":[[2023,10,20]],"date-time":"2023-10-20T00:00:00Z","timestamp":1697760000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,10,20]]},"abstract":"<jats:p>Many studies have reported electromagnetic navigation bronchoscopy (ENB) diagnostic yields and the importance of size and computed tomography (CT) bronchus sign. This study aimed to determine the diagnostic yield of ENB alone, using forceps biopsy and cytology. We analyzed the factors associated with yield and complications according to gross specimen size. This retrospective study included patients who underwent ENB using forceps for suspected lung lesions on CT between January 2020 and December 2022 in South Korea. Factors related to the ENB diagnostic yield and complications were evaluated, and the impacts of gross specimen size and cytology were analyzed. A total of 276 patients were analyzed. The final diagnostic yield was 75.5% after excluding indeterminate cases. Sensitivity and specificity were 74.2% and 100%, respectively. Pneumothorax developed in 1.4% (4\/276) of cases, with no grade 3 or higher bleeding. Univariable analysis showed that the number of biopsies and the size of the gross specimen were related to the diagnosis. Multivariable analyses showed that a larger lesion size on CT was a significant factor for diagnosis. The gross size of the specimens was not significantly associated with epinephrine use. ENB had acceptable diagnostic yield and safety for diagnosing lung lesions with suspected malignancy. Obtaining more tissue through biopsy may not increase bleeding or pneumothorax complications. Identifying patients with lesion characteristics, including CT bronchus sign, would help increase ENB diagnostic yield.<\/jats:p>","DOI":"10.1097\/md.0000000000035362","type":"journal-article","created":{"date-parts":[[2023,10,20]],"date-time":"2023-10-20T15:20:39Z","timestamp":1697815239000},"page":"e35362","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Outcomes of the electromagnetic navigation bronchoscopy using forceps for lung lesion suspected malignancy: A retrospective study"],"prefix":"10.1097","volume":"102","author":[{"given":"Tae Hun","family":"Kim","sequence":"first","affiliation":[{"name":"Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Keimyung University Dongsan Medical Center, Daegu, South Korea."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mi-Ae","family":"Kim","sequence":"additional","affiliation":[{"name":"Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Keimyung University Dongsan Medical Center, Daegu, South Korea."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hyun Jung","family":"Kim","sequence":"additional","affiliation":[{"name":"Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Keimyung University Dongsan Medical Center, Daegu, South Korea."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yong Shik","family":"Kwon","sequence":"additional","affiliation":[{"name":"Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Keimyung University Dongsan Medical Center, Daegu, South Korea."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jae Seok","family":"Park","sequence":"additional","affiliation":[{"name":"Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Keimyung University Dongsan Medical Center, Daegu, South Korea."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9464-0652","authenticated-orcid":false,"given":"Sun Hyo","family":"Park","sequence":"additional","affiliation":[{"name":"Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Keimyung University Dongsan Medical Center, Daegu, South Korea."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250504","doi-asserted-by":"crossref","first-page":"394","DOI":"10.3322\/caac.21492","article-title":"Global cancer statistics 2018: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries.","volume":"68","author":"Bray","year":"2018","journal-title":"CA Cancer J Clin"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1056\/NEJMoa1102873","article-title":"Reduced lung-cancer mortality with low-dose computed tomographic screening.","volume":"365","author":"Aberle","year":"2011","journal-title":"N Engl J Med"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"956","DOI":"10.1164\/rccm.200802-336OC","article-title":"The Pittsburgh Lung Screening Study (PLuSS): outcomes within 3 years of a first computed tomography scan.","volume":"178","author":"Wilson","year":"2008","journal-title":"Am J Respir Crit Care Med"},{"key":"R4-20250504","doi-asserted-by":"crossref","first-page":"497","DOI":"10.6004\/jnccn.2022.0025","article-title":"Non-small cell lung cancer, Version 3.2022, NCCN clinical practice guidelines in oncology.","volume":"20","author":"Ettinger","year":"2022","journal-title":"J Natl Compr Canc Netw"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"864","DOI":"10.3390\/biology10090864","article-title":"Next generation sequencing technology in lung cancer diagnosis.","volume":"10","author":"Cainap","year":"2021","journal-title":"Biology"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"920","DOI":"10.1136\/thorax.58.11.920","article-title":"Guidelines for radiologically guided lung biopsy.","volume":"58","author":"Manhire","year":"2003","journal-title":"Thorax"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1164\/rccm.200612-1866OC","article-title":"Multimodality bronchoscopic diagnosis of peripheral lung lesions: a randomized controlled trial.","volume":"176","author":"Eberhardt","year":"2007","journal-title":"Am J Respir Crit Care Med"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1159\/000355710","article-title":"Diagnostic yield and safety of electromagnetic navigation bronchoscopy for lung nodules: a systematic review and meta-analysis.","volume":"87","author":"Gex","year":"2014","journal-title":"Respiration"},{"key":"R9-20250504","doi-asserted-by":"crossref","first-page":"3263","DOI":"10.21037\/jtd-2019-ndt-11","article-title":"Navigational bronchoscopy: a guide through history, current use, and developing technology.","volume":"12","author":"Cicenia","year":"2020","journal-title":"J Thorac Dis"},{"key":"R10-20250504","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/j.jtho.2018.11.013","article-title":"Electromagnetic navigation bronchoscopy for peripheral pulmonary lesions: one-year results of the prospective, multicenter NAVIGATE study.","volume":"14","author":"Folch","year":"2019","journal-title":"J Thorac Oncol"},{"key":"R11-20250504","doi-asserted-by":"crossref","first-page":"978","DOI":"10.1513\/AnnalsATS.201711-856OC","article-title":"Computed tomography bronchus sign and the diagnostic yield of guided bronchoscopy for peripheral pulmonary lesions. a systematic review and meta-analysis.","volume":"15","author":"Ali","year":"2018","journal-title":"Ann Am Thorac Soc"},{"key":"R12-20250504","doi-asserted-by":"crossref","first-page":"462","DOI":"10.21037\/tlcr-21-846","article-title":"Utility and safety of sole electromagnetic navigation bronchoscopy under moderate sedation for lung cancer diagnosis.","volume":"11","author":"Kim","year":"2022","journal-title":"Transl Lung Cancer Res"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/j.resinv.2016.04.004","article-title":"Computed tomography-guided bronchoscopy in the diagnosis of small peripheral pulmonary lesions: a retrospective study of 240 examinations in a single academic center.","volume":"54","author":"Tokoro","year":"2016","journal-title":"Respir Investig"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"848","DOI":"10.1164\/rccm.201209-1651OC","article-title":"Characteristics of lung cancers detected by computer tomography screening in the randomized NELSON trial.","volume":"187","author":"Horeweg","year":"2013","journal-title":"Am J Respir Crit Care Med"},{"key":"R15-20250504","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1016\/j.chest.2020.01.036","article-title":"Standardized definitions of bleeding after transbronchial lung biopsy: a delphi consensus statement from the nashville working group.","volume":"158","author":"Folch","year":"2020","journal-title":"Chest"},{"key":"R16-20250504","doi-asserted-by":"crossref","first-page":"33","DOI":"10.25259\/JCIS_53_2020","article-title":"Role of computed tomography-guided biopsies in the era of electromagnetic navigational bronchoscopy: a retrospective study of factors predicting diagnostic yield in electromagnetic navigational bronchoscopy and computed tomography biopsies.","volume":"10","author":"Atkins","year":"2020","journal-title":"J Clin Imaging Sci"},{"key":"R17-20250504","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1097\/LBR.0b013e318216cee6","article-title":"Electromagnetic navigational bronchoscopy: an effective and safe approach to diagnose peripheral lung lesions unreachable by conventional bronchoscopy in high-risk patients.","volume":"18","author":"Mahajan","year":"2011","journal-title":"J Bronchol Interv Pulmonol"},{"key":"R18-20250504","doi-asserted-by":"crossref","first-page":"982","DOI":"10.1164\/rccm.200603-344OC","article-title":"Electromagnetic navigation diagnostic bronchoscopy: a prospective study.","volume":"174","author":"Gildea","year":"2006","journal-title":"Am J Respir Crit Care Med"},{"key":"R19-20250504","doi-asserted-by":"crossref","first-page":"935","DOI":"10.1016\/j.chest.2018.04.029","article-title":"The evolutional history of electromagnetic navigation bronchoscopy: state of the art.","volume":"154","author":"Mehta","year":"2018","journal-title":"Chest"},{"key":"R20-20250504","doi-asserted-by":"crossref","first-page":"212","DOI":"10.4103\/JOC.JOC_51_18","article-title":"Cytopathology of pulmonary lesions: a tertiary care center experience.","volume":"35","author":"Ghildiyal","year":"2018","journal-title":"J Cytol"},{"key":"R21-20250504","doi-asserted-by":"crossref","first-page":"7341","DOI":"10.3390\/jcm11247341","article-title":"Efficacy of combining multiple electromagnetic navigation bronchoscopy modalities for diagnosing lung nodules.","volume":"11","author":"Song","year":"2022","journal-title":"J Clin Med"},{"key":"R22-20250504","doi-asserted-by":"crossref","first-page":"1800","DOI":"10.1378\/chest.06-3016","article-title":"Electromagnetic navigation diagnostic bronchoscopy in peripheral lung lesions.","volume":"131","author":"Eberhardt","year":"2007","journal-title":"Chest"},{"key":"R23-20250504","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1159\/000226128","article-title":"Accuracy and feasibility of electromagnetic navigated bronchoscopy under nitrous oxide sedation for pulmonary peripheral opacities: an outpatient study.","volume":"78","author":"Bertoletti","year":"2009","journal-title":"Respiration"},{"key":"R24-20250504","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1097\/LBR.0b013e3182616ece","article-title":"Multicenter experience with electromagnetic navigation bronchoscopy for the diagnosis of pulmonary nodules.","volume":"19","author":"Jensen","year":"2012","journal-title":"J Bronchol Interv Pulmonol"},{"key":"R25-20250504","doi-asserted-by":"crossref","first-page":"1503","DOI":"10.1111\/1759-7714.13930","article-title":"Diagnostic yield and safety of biopsy guided by electromagnetic navigation bronchoscopy for high-risk pulmonary nodules.","volume":"12","author":"Oh","year":"2021","journal-title":"Thorac Cancer"},{"key":"R26-20250504","doi-asserted-by":"crossref","first-page":"1753","DOI":"10.1016\/j.chest.2020.05.534","article-title":"Sensitivity and safety of electromagnetic navigation bronchoscopy for lung cancer diagnosis: systematic review and meta-analysis.","volume":"158","author":"Folch","year":"2020","journal-title":"Chest"},{"key":"R27-20250504","first-page":"S304","article-title":"Transthoracic needle biopsy of the lung.","volume":"7","author":"DiBardino","year":"2015","journal-title":"J Thorac Dis"},{"key":"R28-20250504","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1007\/s00330-016-4357-8","article-title":"Complication rates of CT-guided transthoracic lung biopsy: meta-analysis.","volume":"27","author":"Heerink","year":"2017","journal-title":"Eur Radiol"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000035362","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T02:31:02Z","timestamp":1746325862000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000035362"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10,20]]},"references-count":28,"journal-issue":{"issue":"42","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000035362","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"type":"print","value":"0025-7974"},{"type":"electronic","value":"1536-5964"}],"subject":[],"published":{"date-parts":[[2023,10,20]]}}}