{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T00:05:29Z","timestamp":1747181129270,"version":"3.40.5"},"reference-count":34,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"44","license":[{"start":{"date-parts":[[2023,11,3]],"date-time":"2023-11-03T00:00:00Z","timestamp":1698969600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,11,3]]},"abstract":"<jats:p>To explore the feasibility of using micro-bolus pulse injection method to reduce the dilution effect of pipeline on high concentration injection, and to understand low liquid volume bolus injection based on low injection speed. Using a programmable pulse injection pump, a 25-cm \u2013 long pipeline containing water-soluble fluorescent agent was flushed using different volumes of bolus, and the time spent for the complete disappearance of the fluorescent agent was recorded to evaluate the flushing efficiency. The finite element simulation of 2-phase flow was carried out using computational fluid dynamics (CFD) technology, and the difference of shear rate and pressure distribution in the vein of pulse injection and direct injection of bolus under hemostasis was compared and simulated. Micro-bolus pulse flushing has advantages in completing perfusion imaging applications, such as small volume imaging agent injection. Compared with non-pulse injection, the effective flushing volume decreases by 49.7%, the average injection speed decreases by 56%, and the maintenance time of high shear rate is shorter when using micro-bolus pulse injection. The impact of micro-bolus pulse injection on the vein can achieve the same or even lower negative effects as other injection methods after increasing the hemostatic distance to 100\u2009mm. In the case of bolus injection requiring high concentration and small volume, such as for radiopharmaceutical dynamic imaging, the application of micro-bolus pulse injection is an effective way to overcome the dilution phenomenon of the imaging agent in the pipeline. During hemostasis, the micro-bolus pulse injection needs to control a longer hemostasis distance to reduce the potential impact on peripheral veins.<\/jats:p>","DOI":"10.1097\/md.0000000000035607","type":"journal-article","created":{"date-parts":[[2023,11,28]],"date-time":"2023-11-28T09:01:35Z","timestamp":1701162095000},"page":"e35607","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Flushing effect of micro-bolus pulse injection and its potential impact on peripheral veins under hemostasis"],"prefix":"10.1097","volume":"102","author":[{"given":"Jin","family":"Li","sequence":"first","affiliation":[{"name":"Tianjin Hospital, Tianjin University, Tianjin, People\u2019s Republic of China"},{"name":"CNNC High Energy Equipment (Tianjin) Co., Ltd., Tianjin, People\u2019s Republic of China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yan","family":"Wang","sequence":"additional","affiliation":[{"name":"Tianjin Hospital, Tianjin University, Tianjin, People\u2019s Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6346-6316","authenticated-orcid":false,"given":"Jian-xiong","family":"Ma","sequence":"additional","affiliation":[{"name":"Tianjin Hospital, Tianjin University, Tianjin, People\u2019s Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ben-chao","family":"Dong","sequence":"additional","affiliation":[{"name":"Tianjin Hospital, Tianjin University, Tianjin, People\u2019s Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lei","family":"Sun","sequence":"additional","affiliation":[{"name":"Tianjin Hospital, Tianjin University, Tianjin, People\u2019s Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Zhou","sequence":"additional","affiliation":[{"name":"CNNC High Energy Equipment (Tianjin) Co., Ltd., Tianjin, People\u2019s Republic of China."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250504","doi-asserted-by":"crossref","first-page":"140","DOI":"10.5152\/etd.2018.0014","article-title":"Evaluation of the efficiency of 99mTc-DMSA as a radiopharmaceutical in dynamic renal scans.","volume":"40","author":"Fahmy","year":"2018","journal-title":"Erciyes Med J"},{"key":"R2-20250504","first-page":"99","article-title":"Bone scan and MRI findings in a case of paediatric multifocal osteomyelitis.","volume":"1","author":"Marripudi","year":"2021","journal-title":"Clin Radiol Extra"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s13139-016-0441-x","article-title":"Comparative analysis of (99m)Tc-MDP three-phase bone scan with SPECT\/CT and (99m)Tc-HMPAO-labeled WBC SPECT\/CT in the differential diagnosis of clinically suspicious post-traumatic osteomyelitis.","volume":"51","author":"Kim","year":"2017","journal-title":"Nucl Med Mol Imaging"},{"key":"R4-20250504","first-page":"2590","article-title":"99mTc-HMPAO SPECT imaging reveals brain hypoperfusion during status epilepticus.","volume":"36","author":"Bascuana","year":"2021","journal-title":"Metab Brain Dis"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"1720","DOI":"10.1007\/s00259-012-2174-0","article-title":"Validation of a new protocol for 18F-FDG infusion using an automatic combined dispenser and injector system.","volume":"39","author":"Lecchi","year":"2012","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"2611","DOI":"10.1002\/hed.26732","article-title":"Dynamic contrast-enhanced magnetic resonance imaging for differentiating head and neck paraganglioma and schwannoma.","volume":"43","author":"Malla","year":"2021","journal-title":"Head Neck"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"706","DOI":"10.1007\/s12070-018-1512-3","article-title":"The use of dynamic contrast-enhanced perfusion MRI in differentiating benign and malignant thyroid nodules.","volume":"71","author":"Sakat","year":"2019","journal-title":"Indian J Otolaryngol Head Neck Surg"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"474","DOI":"10.12968\/bjcn.2012.17.10.474","article-title":"Intravenous therapy: guidance on devices, management and care.","volume":"17","author":"Sherri","year":"2012","journal-title":"Br J Community Nurs"},{"key":"R9-20250504","first-page":"379","article-title":"Pulsative flushing as a strategy to prevent bacterial colonization of vascular access devices.","volume":"7","author":"Ferroni","year":"2014","journal-title":"Medical Devices (Auckland, N.Z.)"},{"key":"R10-20250504","first-page":"9","article-title":"Comparison of continuous flush with pulse flush technique in clearing blood contamination of small bore intra vascular catheter: a randomized control trial.","volume":"12","author":"Thandaveshwara","year":"2018","journal-title":"J Clin Diagn Res"},{"key":"R11-20250504","doi-asserted-by":"crossref","first-page":"75","DOI":"10.5301\/JVA.2011.8487","article-title":"Flushing of intravascular access devices (IVADs) - Efficacy of pulsed and continuous infusions.","volume":"13","author":"Guiffant","year":"2012","journal-title":"J Vasc Access"},{"key":"R12-20250504","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1097\/00129804-200605000-00003","article-title":"Technology of flushing vascular access devices.","volume":"29","author":"Hadaway","year":"2006","journal-title":"J Infusion Nurs"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"746","DOI":"10.1002\/jmri.23810","article-title":"A dedicated automated injection system for dynamic contrast-enhanced MRI experiments in mice.","volume":"37","author":"Sedlacik","year":"2013","journal-title":"J Magn Reson Imaging"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"012010","DOI":"10.1088\/1742-6596\/1359\/1\/012010","article-title":"Numerical analysis of the leaflet elasticity effect on the flow in the model of a venous valve.","volume":"1359","author":"Gataulin","year":"2019","journal-title":"J Phys Conf Ser"},{"key":"R15-20250504","doi-asserted-by":"crossref","first-page":"012041","DOI":"10.1088\/1742-6596\/1697\/1\/012041","article-title":"Fluid-structure interaction modelling of the venous valve with elastic leaflets.","volume":"1697","author":"Tikhomolova","year":"2020","journal-title":"J Phys Conf Ser"},{"key":"R16-20250504","doi-asserted-by":"crossref","first-page":"3441","DOI":"10.1038\/s41598-018-21617-1","article-title":"The mechanistic causes of peripheral intravenous catheter failure based on a parametric computational study.","volume":"8","author":"Piper","year":"2018","journal-title":"Sci Rep"},{"key":"R17-20250504","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1152\/advan.00182.2018","article-title":"Understanding basic vein physiology and venous blood pressure through simple physical assessments.","volume":"43","author":"Tansey","year":"2019","journal-title":"AJP Adv Physiol Educ"},{"key":"R18-20250504","doi-asserted-by":"crossref","first-page":"1426","DOI":"10.1007\/s10439-009-9895-7","article-title":"Partitioned fluid\u2013Solid coupling for cardiovascular blood flow.","volume":"38","author":"Krittian","year":"2010","journal-title":"Ann Biomed Eng"},{"key":"R19-20250504","doi-asserted-by":"crossref","first-page":"105560","DOI":"10.1016\/j.cmpb.2020.105560","article-title":"Insight into the significance of blood flow inside stenosis coronary jointed with bypass vein: the case of anemic, normal, and hypertensive individuals.","volume":"196","author":"Rostami","year":"2020","journal-title":"Comput Methods Programs Biomed"},{"key":"R20-20250504","doi-asserted-by":"crossref","first-page":"011003","DOI":"10.1115\/1.2838029","article-title":"Effect of blood viscosity on oxygen transport in residual stenosed artery following angioplasty.","volume":"130","author":"Kwon","year":"2008","journal-title":"J Biomech Eng"},{"key":"R21-20250504","doi-asserted-by":"crossref","first-page":"1116","DOI":"10.1016\/j.jbiomech.2005.01.034","article-title":"Non-Newtonian blood flow in human right coronary arteries: transient simulations.","volume":"39","author":"Johnston","year":"2006","journal-title":"J Biomech"},{"key":"R22-20250504","first-page":"171","article-title":"Non-newtonian blood flow in portal vein with thrombosis: a study by computational fluid dynamics.","volume":"1","author":"Soares","year":"2011","journal-title":"Am Institute Phys Conf Serives"},{"key":"R24-20250504","doi-asserted-by":"crossref","first-page":"1599","DOI":"10.1016\/S0021-9290(02)00231-2","article-title":"Computational model of the fluid dynamics of a cannula inserted in a vessel incidence of the presence of side holes in blood flow.","volume":"35","author":"Grigioni","year":"2002","journal-title":"J Biomech"},{"key":"R25-20250504","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1093\/rpd\/ncv077","article-title":"Evaluation of an automated FDG dose infuser to PET-CT patients.","volume":"165","author":"S\u00e1nchez","year":"2015","journal-title":"Radiat Prot Dosim"},{"key":"R26-20250504","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1038\/s42256-020-0148-7","article-title":"Deep learning robotic guidance for autonomous vascular access.","volume":"2","author":"Chen","year":"2020","journal-title":"Nat Mach Intell"},{"key":"R27-20250504","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1097\/NAN.0000000000000311","article-title":"Pulsatile flushing: a review of the literature.","volume":"42","author":"Boord","year":"2019","journal-title":"J Infusion Nurs"},{"key":"R28-20250504","doi-asserted-by":"crossref","first-page":"803","DOI":"10.1016\/j.cherd.2011.10.004","article-title":"The fouling and cleaning of venous catheters: a possible optimization of the process using intermittent flushing.","volume":"90","author":"Royon","year":"2012","journal-title":"Chem Eng Res Des"},{"key":"R29-20250504","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1097\/NAN.0b013e31825af099","article-title":"Short peripheral intravenous catheters and infections.","volume":"35","author":"Hadaway","year":"2012","journal-title":"J Infusion Nurs"},{"key":"R30-20250504","doi-asserted-by":"crossref","first-page":"S38","DOI":"10.1016\/S0924-8579(09)70565-5","article-title":"Peripheral venous catheters: an under-evaluated problem.","volume":"34","author":"Zingg","year":"2009","journal-title":"Int J Antimicrob Agents"},{"key":"R31-20250504","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1111\/hdi.12029","article-title":"The flow field near a venous needle in hemodialysis: a computational study.","volume":"17","author":"Fulker","year":"2013","journal-title":"Hemodial Int Int Symp Home Hemodial"},{"key":"R32-20250504","first-page":"1","article-title":"Mechanical compression effects on the secretion of vWF and IL-8 by cultured human vein endothelium.","volume":"12","author":"Dar","year":"2017","journal-title":"PLoS One"},{"key":"R33-20250504","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s13063-016-1470-6","article-title":"Varied flushing frequency and volume to prevent peripheral intravenous catheter failure: a pilot, factorial randomised controlled trial in adult medical-surgical hospital patients.","volume":"17","author":"Keogh","year":"2016","journal-title":"Trials"},{"key":"R34-20250504","doi-asserted-by":"crossref","first-page":"105103","DOI":"10.1016\/j.clinbiomech.2020.105103","article-title":"Mechanism of pulsatile flushing technique for saline injection via a peripheral intravenous catheter.","volume":"80","author":"Zhu","year":"2020","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"R35-20250504","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1097\/NAN.0000000000000100","article-title":"Accepted but unacceptable: peripheral IV catheter failure.","volume":"38","author":"Klemperer","year":"2015","journal-title":"J Infus Nurs"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000035607","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T02:16:50Z","timestamp":1746325010000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000035607"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,3]]},"references-count":34,"journal-issue":{"issue":"44","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000035607","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"type":"print","value":"0025-7974"},{"type":"electronic","value":"1536-5964"}],"subject":[],"published":{"date-parts":[[2023,11,3]]}}}