{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T05:16:53Z","timestamp":1791523013094,"version":"4.3.4"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"47","license":[{"start":{"date-parts":[[2023,11,24]],"date-time":"2023-11-24T00:00:00Z","timestamp":1700784000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,11,24]]},"abstract":"<jats:p>The purpose of the present study was to evaluate the subjectively perceived patient comfort during magnetic resonance imaging (MRI) examinations and to assess potential differences between a recently introduced low field MRI scanner and a standard MRI scanner. Among other characteristics, the low field MRI scanner differs from the standard MRI scanner by offering more space (wider bore size of 80 centimeter diameter) and producing less noise, which may influence the patient comfort. In total, 177 patients were surveyed after MRI scans with either the low field MRI scanner (n = 91, <jats:italic toggle=\"yes\">MAGNETOM Free.Max, Siemens Healthineers<\/jats:italic>) or the standard MRI scanner (n = 86, <jats:italic toggle=\"yes\">MAGNETOM Avanto Fit, Siemens Healthineers<\/jats:italic>). Patients rated different aspects of comfort on a 5 point Likert scale: (a) claustrophobia, (b) comfort of the scanner table, (c) noise level and (d) vertigo during the scanning procedure. In terms of claustrophobia and comfort of the scanner table, patients rated both MRI scanners similar (e.g., mean ratings for claustrophobia: standard MRI scanner = 4.63\u2009\u00b1\u20091.04, low field MRI scanner = 4.65\u2009\u00b1\u20091.02). However, when asked for a comparison, patients did favor the more spacious low field MRI scanner. In terms of noise level, the low field MRI scanner was rated significantly better (mean ratings: standard MRI scanner = 3.72\u2009\u00b1\u20091.46 [median 4 = \u201crather not unpleasant\u201d], low field MRI scanner = 4.26\u2009\u00b1\u20091.22 [median 5 = \u201cnot unpleasant at all\u201d]). Patients did not perceive any significant difference in terms of vertigo between both MRI scanners. The newly developed low field MRI scanner offers constructional differences compared to standard MRI scanners that are perceived positively by patients. Worth highlighting is the significantly lower noise level and the innovative bore diameter of 80 centimeter, which offers more space to the patients.<\/jats:p>","DOI":"10.1097\/md.0000000000036069","type":"journal-article","created":{"date-parts":[[2023,12,4]],"date-time":"2023-12-04T19:04:28Z","timestamp":1701716668000},"page":"e36069","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":11,"title":["Does bore size matter?\u2014A comparison of the subjective perception of patient comfort during low field (0.55 Tesla) and standard (1.5 Tesla) MRI imaging"],"prefix":"10.1097","volume":"102","author":[{"given":"Arwed Elias","family":"Michael","sequence":"first","affiliation":[{"name":"Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andreas","family":"Heuser","sequence":"additional","affiliation":[{"name":"Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christoph","family":"Moenninghoff","sequence":"additional","affiliation":[{"name":"Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexey","family":"Surov","sequence":"additional","affiliation":[{"name":"Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"Borggrefe","sequence":"additional","affiliation":[{"name":"Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan Robert","family":"Kroeger","sequence":"additional","affiliation":[{"name":"Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0103-3819","authenticated-orcid":false,"given":"Julius Henning","family":"Niehoff","sequence":"additional","affiliation":[{"name":"Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250524","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1007\/s13244-017-0566-1","article-title":"ESR concept paper on value-based radiology.","volume":"8","year":"2017","journal-title":"Insights Imaging"},{"key":"R2-20250524","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1186\/s13244-021-01056-9","article-title":"Value-based radiology: what is the ESR doing, and what should we do in the future?","volume":"12","author":"Brady","year":"2021","journal-title":"Insights Imaging"},{"key":"R3-20250524","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1186\/s13244-020-00943-x","article-title":"Patient survey of value in relation to radiology: results from a survey of the European Society of Radiology (ESR) value-based radiology subcommittee.","volume":"12","author":"Fuchsj\u00e4ger","year":"2021","journal-title":"Insights Imaging"},{"key":"R4-20250524","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1148\/radiology.170.2.2911670","article-title":"Anxiety in patients undergoing MR imaging.","volume":"170","author":"Quirk","year":"1989","journal-title":"Radiology"},{"key":"R5-20250524","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/0005-7916(94)90005-1","article-title":"Anxiety and its determinants in patients undergoing Magnetic Resonance Imaging.","volume":"25","author":"Katz","year":"1994","journal-title":"J Behav Ther Exp Psychiatry"},{"key":"R6-20250524","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1016\/S0009-9260(05)83042-9","article-title":"Patients\u2019 perceptions of magnetic resonance imaging.","volume":"50","author":"Mackenzie","year":"1995","journal-title":"Clin Radiol"},{"key":"R7-20250524","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1002\/jmri.23904","article-title":"Subject tolerance of 7 T MRI examinations.","volume":"38","author":"Versluis","year":"2013","journal-title":"J Magn Reson Imaging"},{"key":"R8-20250524","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1007\/s10334-007-0095-x","article-title":"Subjective acceptance of 7 Tesla MRI for human imaging.","volume":"21","author":"Theysohn","year":"2008","journal-title":"MAGMA"},{"key":"R9-20250524","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1002\/bem.20680","article-title":"A large-scale study on subjective perception of discomfort during 7 and 15 T MRI examinations.","volume":"32","author":"Heilmaier","year":"2011","journal-title":"Bioelectromagnetics"},{"key":"R10-20250524","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1097\/RLI.0000000000000035","article-title":"Multicenter study of subjective acceptance during magnetic resonance imaging at 7 and 94 T.","volume":"49","author":"Rauschenberg","year":"2014","journal-title":"Invest Radiol"},{"key":"R11-20250524","doi-asserted-by":"crossref","first-page":"e59","DOI":"10.1016\/j.radi.2014.12.004","article-title":"Claustrophobia in magnetic resonance imaging: a systematic review and meta-analysis.","volume":"21","author":"Munn","year":"2015","journal-title":"Radiography"},{"key":"R12-20250524","doi-asserted-by":"crossref","first-page":"1325","DOI":"10.1007\/s00330-020-07060-9","article-title":"Patient preferences for development in MRI scanner design: a survey of claustrophobic patients in a randomized study.","volume":"31","author":"Iwan","year":"2021","journal-title":"Eur Radiol"},{"key":"R13-20250524","doi-asserted-by":"crossref","first-page":"1322","DOI":"10.1002\/jmri.21147","article-title":"Claustrophobia during magnetic resonance imaging: cohort study in over 55,000 patients.","volume":"26","author":"Dewey","year":"2007","journal-title":"J Magn Reson Imaging"},{"key":"R14-20250524","doi-asserted-by":"crossref","first-page":"1916","DOI":"10.3390\/jcm12051916","article-title":"Diagnostic image quality of a low-field (055T) knee MRI protocol using deep learning image reconstruction compared with a standard (15T) knee MRI protocol.","volume":"12","author":"Lopez Schmidt","year":"2023","journal-title":"J Clin Med"},{"key":"R15-20250524","first-page":"76","article-title":"Modern low-field MRI of the musculoskeletal system: practice considerations, opportunities, and challenges.","volume":"58","author":"Khodarahmi","year":"2023","journal-title":"Invest Radiol"},{"key":"R16-20250524","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.mri.2020.11.004","article-title":"High-performance low field MRI enables visualization of persistent pulmonary damage after COVID-19.","volume":"76","author":"Heiss","year":"2021","journal-title":"Magn Reson Imaging"},{"key":"R17-20250524","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1002\/jmri.28408","article-title":"Low-field MRI: clinical promise and challenges.","volume":"57","author":"Arnold","year":"2023","journal-title":"J Magn Reson Imaging"},{"key":"R18-20250524","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1007\/s00117-022-00986-9","article-title":"[Economic aspects of low-field magnetic resonance imaging: acquisition, installation, and maintenance costs of 055 T systems].","volume":"62","author":"Vosshenrich","year":"2022","journal-title":"Radiologe"},{"key":"R19-20250524","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1097\/RLI.0000000000000703","article-title":"Advocating the development of next-generation, advanced-design low-field magnetic resonance systems.","volume":"55","author":"Runge","year":"2020","journal-title":"Invest Radiol"},{"key":"R20-20250524","doi-asserted-by":"crossref","first-page":"6705","DOI":"10.3390\/jcm11226705","article-title":"More space, less noise\u2014new-generation low-field magnetic resonance imaging systems can improve patient comfort: a prospective 055T\u201315T-scanner comparison.","volume":"11","author":"Rusche","year":"2022","journal-title":"J Clin Med"},{"key":"R21-20250524","doi-asserted-by":"crossref","first-page":"1401","DOI":"10.3390\/tomography8030113","article-title":"Patient comfort in modern computed tomography: what really counts.","volume":"8","author":"Niehoff","year":"2022","journal-title":"Tomography"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000036069","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,24]],"date-time":"2025-05-24T18:00:29Z","timestamp":1748109629000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000036069"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,24]]},"references-count":21,"journal-issue":{"issue":"47","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000036069","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,24]]}}}