{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T21:58:29Z","timestamp":1777586309136,"version":"3.51.4"},"reference-count":31,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2024,1,5]],"date-time":"2024-01-05T00:00:00Z","timestamp":1704412800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,1,5]]},"abstract":"<jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>This systematic literature review and meta-analysis aimed to assess the accuracy, sensitivity, and specificity of dual-energy computed tomography (DECT) of the sacroiliac joint. Bone marrow edema (BME) of the sacroiliac joint is an early manifestation of some diseases, such as ankylosing spondylitis, and is usually examined by nuclear magnetic resonance imaging (MRI); however, MRI can be intolerable for some patients; hence, numerous studies have analyzed DECT examinations.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>We searched PUBMED, CNKI, and EMBASE in 2023 for articles containing the following terms (DECT) or (DE-CT) or (dual-energy CT) or \u201cdual-energy CT\u201d or (dual-energy computed tomography) and ((sacroiliac joint) or (ankylosing spondylitis) or (sacroiliac arthritis) or (sacroiliitis)). An initial search identified 444 articles, of which 7 met the criteria. Data were extracted to calculate the sensitivity, specificity, and diagnostic odds for analysis using R software.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Out of 291 patients and 577 sacroiliac joints, 429 (74.35%) exhibited BME. All studies used magnetic resonance as the control group. The overall sensitivity and specificity of DECT were 79%, and 92%, respectively, with positive prediction rate of 92.55% and negative prediction rate of 83.73%.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>DECT appears to be a promising diagnostic tool for detecting BME in the sacroiliac joint and can be used as an alternative examination method for patients in whom MRI is contraindicated.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000036708","type":"journal-article","created":{"date-parts":[[2024,1,10]],"date-time":"2024-01-10T07:01:18Z","timestamp":1704870078000},"page":"e36708","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":9,"title":["Accuracy of dual-energy computed tomography for bone marrow edema in the sacroiliac joint: A systematic review and meta-analysis"],"prefix":"10.1097","volume":"103","author":[{"ORCID":"https:\/\/orcid.org\/0009-0003-4236-7679","authenticated-orcid":false,"given":"Xin","family":"Li","sequence":"first","affiliation":[{"name":"Shandong University of Traditional Chinese Medicine, Jinan, Shandong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-2761-5565","authenticated-orcid":false,"given":"Jianguo","family":"Wang","sequence":"additional","affiliation":[{"name":"Shandong University of Traditional Chinese Medicine Affiliated Hospital, Jinan, Shandong, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ping","family":"Li","sequence":"additional","affiliation":[{"name":"Shandong University of Traditional Chinese Medicine Affiliated Hospital, Jinan, Shandong, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shunda","family":"Zhuang","sequence":"additional","affiliation":[{"name":"Shandong University of Traditional Chinese Medicine Affiliated Hospital, Jinan, Shandong, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shun","family":"Jiang","sequence":"additional","affiliation":[{"name":"Shandong University of Traditional Chinese Medicine Affiliated Hospital, Jinan, Shandong, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wenqian","family":"Liu","sequence":"additional","affiliation":[{"name":"Shandong University of Traditional Chinese Medicine Affiliated Hospital, Jinan, Shandong, China."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250503","first-page":"434","article-title":"Bone marrow edema: pathogenetic features.","volume":"173","author":"Molfetta","year":"2022","journal-title":"Clin Ther"},{"key":"R2-20250503","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1186\/s13244-022-01312-6","article-title":"Traumatic bone marrow lesions in dual-energy computed tomography.","volume":"13","author":"Ren","year":"2022","journal-title":"Insights Imaging"},{"key":"R3-20250503","doi-asserted-by":"crossref","first-page":"110359","DOI":"10.1016\/j.ejrad.2022.110359","article-title":"Diagnostic accuracy of dual-energy computed tomography (DECT) to detect non-traumatic bone marrow edema: a systematic review and meta-analysis.","volume":"153","author":"Chen","year":"2022","journal-title":"Eur J Radiol"},{"key":"R4-20250503","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1148\/radiol.2021203624","article-title":"DECT in detection of vertebral fracture-associated bone marrow Edema: a systematic review and meta-analysis with emphasis on technical and imaging interpretation parameters.","volume":"300","author":"Ghazi Sherbaf","year":"2021","journal-title":"Radiology"},{"key":"R5-20250503","doi-asserted-by":"crossref","first-page":"871","DOI":"10.1007\/s00256-020-03646-y","article-title":"Diagnostic accuracy of dual-energy CT for detecting bone marrow edema in patients with acute knee injuries: a systematic review and meta-analysis.","volume":"50","author":"Wilson","year":"2021","journal-title":"Skeletal Radiol"},{"key":"R6-20250503","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1148\/radiol.2382050062","article-title":"Follow-up of occult bone lesions detected at MR imaging: systematic review.","volume":"238","author":"Boks","year":"2006","journal-title":"Radiology"},{"key":"R7-20250503","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1148\/126.1.255","article-title":"Split-detector computed tomography: a preliminary report.","volume":"126","author":"Brooks","year":"1978","journal-title":"Radiology"},{"key":"R8-20250503","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1097\/00004728-197710000-00016","article-title":"A quantitative theory of the Hounsfield unit and its application to dual energy scanning.","volume":"1","author":"Brooks","year":"1997","journal-title":"J Comput Assist Tomogr"},{"key":"R9-20250503","doi-asserted-by":"crossref","first-page":"696","DOI":"10.1136\/ard.56.11.696a","article-title":"Serum uric acid in acute gout.","volume":"56","author":"Logan","year":"1997","journal-title":"Ann Rheum Dis"},{"key":"R10-20250503","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1259\/0007-1285-57-673-82","article-title":"Some practical aspects of dual-energy CT scanning.","volume":"57","author":"Dunscombe","year":"1984","journal-title":"Br J Radiol"},{"key":"R11-20250503","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1097\/RLI.0000000000000908","article-title":"Computed tomography: state-of-the-art advancements in musculoskeletal imaging.","volume":"58","author":"Ibad","year":"2023","journal-title":"Invest Radiol"},{"key":"R12-20250503","doi-asserted-by":"crossref","first-page":"2110","DOI":"10.1016\/j.acra.2022.11.020","article-title":"Association of phantomless dual-energy CT-based volumetric bone mineral density with the prevalence of acute insufficiency fractures of the spine.","volume":"30","author":"Gruenewald","year":"2022","journal-title":"Acad Radiol"},{"key":"R13-20250503","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.jclinepi.2009.06.006","article-title":"The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration.","volume":"62","author":"Liberati","year":"2009","journal-title":"J Clin Epidemiol"},{"key":"R14-20250503","doi-asserted-by":"crossref","first-page":"1175","DOI":"10.3348\/kjr.2015.16.6.1175","article-title":"Systematic review and meta-analysis of studies evaluating diagnostic test accuracy: a practical review for clinical researchers-part I. General guidance and tips.","volume":"16","author":"Kim","year":"2015","journal-title":"Korean J Radiol"},{"key":"R15-20250503","doi-asserted-by":"crossref","first-page":"529","DOI":"10.7326\/0003-4819-155-8-201110180-00009","article-title":"QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies.","volume":"155","author":"Whiting","year":"2011","journal-title":"Ann Intern Med"},{"key":"R16-20250503","doi-asserted-by":"crossref","first-page":"1188","DOI":"10.3348\/kjr.2015.16.6.1188","article-title":"Systematic review and meta-analysis of studies evaluating diagnostic test accuracy: a practical review for clinical researchers-part II. Statistical methods of meta-analysis.","volume":"16","author":"Lee","year":"2015","journal-title":"Korean J Radiol"},{"key":"R17-20250503","doi-asserted-by":"crossref","first-page":"5","DOI":"10.3348\/kjr.2016.17.1.5","article-title":"Successful publication of systematic review and meta-analysis of studies evaluating diagnostic test accuracy.","volume":"17","author":"Suh","year":"2016","journal-title":"Korean J Radiol"},{"key":"R18-20250503","doi-asserted-by":"crossref","first-page":"d5928","DOI":"10.1136\/bmj.d5928","article-title":"The Cochrane Collaboration\u2019s Tool for assessing risk of bias in randomised trials.","volume":"343","author":"Higgins","year":"2011","journal-title":"BMJ"},{"key":"R19-20250503","doi-asserted-by":"crossref","first-page":"3393","DOI":"10.1007\/s00330-020-06670-7","article-title":"Bone marrow edema in sacroiliitis: detection with dual-energy CT.","volume":"30","author":"Chen","year":"2020","journal-title":"Eur Radiol"},{"key":"R20-20250503","first-page":"1234","article-title":"Value of dual-energy CT for diagnosis of bone marrow edema in the sacroiliac joint.","volume":"27","author":"Chen","year":"2021","journal-title":"J Hainan Med Coll"},{"key":"R21-20250503","first-page":"1157","article-title":"Value of CT spectroscopy imaging in the diagnosis of bone marrow edema and activity of sacroiliac joints in early ankylosing spondylitis.","volume":"34","author":"Song","year":"2020","journal-title":"Chin J Pract Diagn Treatment"},{"key":"R22-20250503","first-page":"2101","article-title":"Quantitative analysis of bone marrow edema material changes in sacroiliac arthritis by bipotent CT material separation technique.","volume":"41","author":"Yang","year":"2022","journal-title":"J Clin Radiol"},{"key":"R23-20250503","first-page":"893","article-title":"Discussion of the application of dual-energy CT imaging technology in sacroiliac arthritis.","volume":"30","author":"He","year":"2020","journal-title":"Southwest Natl Defense Med"},{"key":"R24-20250503","doi-asserted-by":"crossref","first-page":"1316","DOI":"10.55563\/clinexprheumatol\/xdlfzb","article-title":"Dual-energy computed tomography for the detection of sacroiliac joints bone marrow oedema in patients with axial spondyloarthritis.","volume":"39","author":"Carotti","year":"2021","journal-title":"Clin Exp Rheumatol"},{"key":"R25-20250503","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1148\/radiol.2018181168","article-title":"Axial spondyloarthritis: dual-energy virtual noncalcium CT in the detection of bone marrow edema in the sacroiliac joints.","volume":"290","author":"Wu","year":"2019","journal-title":"Radiology"},{"key":"R26-20250503","doi-asserted-by":"crossref","first-page":"2201","DOI":"10.3390\/cancers7040886","article-title":"Multiparametric evaluation of head and neck squamous cell carcinoma using a single-source dual-energy CT with fast kVp switching: state of the art.","volume":"7","author":"Lam","year":"2015","journal-title":"Cancers (Basel)"},{"key":"R27-20250503","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1177\/230949901101900203","article-title":"Sensitivity, specificity and accuracy of magnetic resonance imaging for differentiating vertebral compression fractures caused by malignancy, osteoporosis, and infections.","volume":"19","author":"Abdel-Wanis","year":"2011","journal-title":"J Orthop Surg (Hong Kong)"},{"key":"R28-20250503","doi-asserted-by":"crossref","first-page":"762","DOI":"10.2298\/VSP1109762J","article-title":"Bone bruise of the knee associated with the lesions of anterior cruciate ligament and menisci on magnetic resonance imaging.","volume":"68","author":"Jelic","year":"2011","journal-title":"Vojnosanit Pregl"},{"key":"R29-20250503","first-page":"105731G","article-title":"Three-material decomposition in multi-energy CT: impact of prior information on noise and bias.","volume":"10573","author":"Ren","year":"2018","journal-title":"Proc SPIE Int Soc Opt Eng"},{"key":"R30-20250503","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1016\/j.ejrad.2017.12.018","article-title":"Diagnostic accuracy of dual-energy computed tomography in bone marrow edema with vertebral compression fractures: a meta-analysis.","volume":"99","author":"Yang","year":"2018","journal-title":"Eur J Radiol"},{"key":"R31-20250503","doi-asserted-by":"crossref","first-page":"949","DOI":"10.2214\/ajr.183.4.1830949","article-title":"Diagnosis of osteoporotic vertebral fractures: importance of recognition and description by radiologists.","volume":"183","author":"Lenchik","year":"2004","journal-title":"AJR Am J Roentgenol"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000036708","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T00:23:14Z","timestamp":1746318194000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000036708"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,5]]},"references-count":31,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000036708","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,5]]}}}