{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,16]],"date-time":"2026-11-16T09:12:39Z","timestamp":1794820359362,"version":"4.9.1"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","license":[{"start":{"date-parts":[[2024,3,22]],"date-time":"2024-03-22T00:00:00Z","timestamp":1711065600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,3,22]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>Cosmetic iris implants have a record of high ocular complications and are no longer in use. These complications include glaucoma, corneal decompensation, iris atrophy, uveitis, cataract and retinal detachment.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Case presentation:<\/jats:title>\n            <jats:p>We report a case of a 44-year-old lady presented with bilateral total iris atrophy, glaucoma and corneal decompensation after cosmetic artificial iris implantation. The patient underwent bilateral artificial iris removal, glaucoma drainage device for the right eye, and micropulse laser for the left eye. In addition, she underwent phacoemulsification with iris-diaphragm intraocular lens implant for the right. The cornea of the right eye ended up with successful Boston keratoprosthesis after rejection of previous 2 grafts.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>To the best of our knowledge, we describe the first report of bilateral total iris atrophy following a cosmetic iris implant accompanied by bilateral glaucoma and corneal decompensation.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000037457","type":"journal-article","created":{"date-parts":[[2024,4,1]],"date-time":"2024-04-01T18:04:42Z","timestamp":1711994682000},"page":"e37457","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Bilateral total iris atrophy, corneal decompensation and glaucoma following bilateral cosmetic artificial iris implantation: A case report of severe sequela and successful management"],"prefix":"10.1097","volume":"103","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5452-1608","authenticated-orcid":false,"given":"Wisam","family":"Shihadeh","sequence":"first","affiliation":[{"name":"Division of Ophthalmology, Department of Special Surgery, Faculty of Medicine Jordan University of Science and Technology, Irbid, Jordan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdelwahab","family":"Aleshawi","sequence":"additional","affiliation":[{"name":"Division of Ophthalmology, Department of Special Surgery, Faculty of Medicine Jordan University of Science and Technology, Irbid, Jordan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yara","family":"Aburamadan","sequence":"additional","affiliation":[{"name":"University College London, Hospital NHS Trust, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammed","family":"Al-Shalakhti","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, Yarmouk University, Irbid, Jordan."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250503","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1186\/s12886-015-0084-1","article-title":"Mearza a complications secondary to cosmetic artificial iris anterior chamber implants: a case report.","volume":"15","author":"Shweikh","year":"2015","journal-title":"BMC Ophthalmol"},{"key":"R2-20250503","doi-asserted-by":"crossref","first-page":"e107","DOI":"10.1016\/j.jfo.2014.12.004","article-title":"Ocular complications of the NewColorIris(\u00ae) colored cosmetic implant.","volume":"38","author":"Mathis","year":"2015","journal-title":"J Fr Ophtalmol"},{"key":"R3-20250503","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1016\/j.jcrs.2013.12.027","article-title":"Surgical technique for explantation of cosmetic anterior chamber iris implants.","volume":"41","author":"Arjmand","year":"2015","journal-title":"J Cataract Refract Surg"},{"key":"R4-20250503","doi-asserted-by":"crossref","first-page":"1098","DOI":"10.1136\/bjophthalmol-2015-307295","article-title":"Iritis, glaucoma and corneal decompensation associated with BrightOcular cosmetic iris implant.","volume":"100","author":"Mansour","year":"2016","journal-title":"Br J Ophthalmol"},{"key":"R5-20250503","doi-asserted-by":"crossref","first-page":"1732","DOI":"10.1016\/S0886-3350(01)01124-5","article-title":"Prosthetic iris implantation for congenital, traumatic, or functional iris deficiencies.","volume":"27","author":"Burk","year":"2001","journal-title":"J Cataract Refract Surg"},{"key":"R6-20250503","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1038\/sj.eye.6701448","article-title":"Surgical management of iris defects with prosthetic iris devices.","volume":"19","author":"Mavrikakis","year":"2005","journal-title":"Eye (London, England)"},{"key":"R7-20250503","doi-asserted-by":"crossref","first-page":"357","DOI":"10.3928\/1542-8877-20020901-03","article-title":"Pars plana vitrectomy and transscleral fixation of black diaphragm intraocular lens for the management of traumatic aniridia.","volume":"33","author":"Omulecki","year":"2002","journal-title":"Ophthalmic Surg Lasers"},{"key":"R8-20250503","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1007\/s00417-004-1058-9","article-title":"Black diaphragm aniridia intraocular lens for aniridia and albinism.","volume":"243","author":"Wong","year":"2005","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R9-20250503","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1016\/S0886-3350(99)00432-0","article-title":"Black diaphragm aniridia intraocular lens for congenital aniridia: longterm follow-up.","volume":"26","author":"Reinhard","year":"2000","journal-title":"J Cataract Refract Surg"},{"key":"R10-20250503","doi-asserted-by":"crossref","first-page":"1494","DOI":"10.1016\/j.jcrs.2007.04.030","article-title":"Transscleral fixation of a black diaphragm intraocular lens in severely traumatized eyes requiring vitreoretinal surgery.","volume":"33","author":"Ozbek","year":"2007","journal-title":"J Cataract Refract Surg"},{"key":"R11-20250503","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1016\/j.jcrs.2011.09.037","article-title":"Serious ocular complications of cosmetic iris implants in 14 eyes.","volume":"38","author":"Hoguet","year":"2012","journal-title":"J Cataract Refract Surg"},{"key":"R12-20250503","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/j.clae.2010.03.001","article-title":"Complications and management of cosmetic anterior chamber iris implants.","volume":"33","author":"Hull","year":"2010","journal-title":"Cont Lens Anterior Eye"},{"key":"R13-20250503","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1111\/j.1755-3768.2008.01499.x","article-title":"Serious complications of cosmetic NewColorIris implantation.","volume":"88","author":"Anderson","year":"2010","journal-title":"Acta Ophthalmol"},{"key":"R14-20250503","doi-asserted-by":"crossref","first-page":"872","DOI":"10.1016\/j.ajo.2010.11.010","article-title":"George bilateral irreversible severe vision loss from cosmetic iris implants.","volume":"151","author":"George","year":"2011","journal-title":"Am J Ophthalmol"},{"key":"R15-20250503","first-page":"435","article-title":"Complications of NewColorIris implantation in phakic eyes: a review.","volume":"5","author":"Sikder","year":"2011","journal-title":"Clin Ophthalmol"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000037457","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T00:30:00Z","timestamp":1746318600000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000037457"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,22]]},"references-count":15,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000037457","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,3,22]]}}}