{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T07:18:04Z","timestamp":1784013484650,"version":"3.55.0"},"reference-count":7,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"14","license":[{"start":{"date-parts":[[2024,4,5]],"date-time":"2024-04-05T00:00:00Z","timestamp":1712275200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,4,5]]},"abstract":"<jats:sec>\n            <jats:title>Rationale:<\/jats:title>\n            <jats:p>Guide wire aspiration during central venous catheter (CVC) insertion in a patient on extracorporeal membrane oxygenation (ECMO) is a very rare but dangerous complication. A guide wire aspirated inside the ECMO can cause thrombosis, the ECMO to break down or shut off, and unnecessary ECMO replacement.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patient concerns:<\/jats:title>\n            <jats:p>A 58-year-old man was scheduled for venovenous ECMO for acute respiratory distress syndrome. After his vital signs stabilized, we inserted a CVC. During CVC insertion, the guide wire was aspirated into the ECMO venous line.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Intervention:<\/jats:title>\n            <jats:p>After confirming the guide wire inside the ECMO venous line, we replaced the entire ECMO circuit.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Outcomes:<\/jats:title>\n            <jats:p>ECMO was maintained for 57 days, and weaning was successful but the patient died 5 days afterward.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Lessons:<\/jats:title>\n            <jats:p>Care must be taken when inserting a CVC using a guide wire in ECMO patients: the guide wire should not be inserted deeply, it should be secured during insertion, the ECMO venous cannula tip requires proper positioning, and ECMO flow should be temporarily reduced.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000037638","type":"journal-article","created":{"date-parts":[[2024,4,5]],"date-time":"2024-04-05T18:02:59Z","timestamp":1712340179000},"page":"e37638","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Intravascular guide wire aspiration in a patient on extracorporeal membrane oxygenation: A case report"],"prefix":"10.1097","volume":"103","author":[{"given":"Jae Ho","family":"Choi","sequence":"first","affiliation":[{"name":"Department of Thoracic and Cardiovascular surgery, Soonchunhyang University Hospital Seoul, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jae Hwa","family":"Yoo","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Pain Medicine, Soonchunhyang University Hospital Seoul, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Won Ho","family":"Chang","sequence":"additional","affiliation":[{"name":"Department of Thoracic and Cardiovascular surgery, Soonchunhyang University Hospital Seoul, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Young Woo","family":"Park","sequence":"additional","affiliation":[{"name":"Department of Thoracic and Cardiovascular surgery, Soonchunhyang University Hospital Seoul, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hyun Jo","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Thoracic and Cardiovascular surgery, Soonchunhyang University Hospital Seoul, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7322-8450","authenticated-orcid":false,"given":"Hong Chul","family":"Oh","sequence":"additional","affiliation":[{"name":"Department of Thoracic and Cardiovascular surgery, Soonchunhyang University Hospital Seoul, Seoul, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250504","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/j.accpm.2017.05.005","article-title":"Central venous catheter placement during extracorporeal membrane oxygenation therapy.","volume":"37","author":"Picard","year":"2018","journal-title":"Anaesth Crit Care Pain Med"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1016\/j.jclinane.2004.11.007","article-title":"The human error: delayed diagnosis of intravascular loss of guidewires for central venous catheterization.","volume":"17","author":"Auweiler","year":"2005","journal-title":"J Clin Anesth"},{"key":"R3-20250504","first-page":"287261","article-title":"Guidewire-related complications during central venous catheter placement: a case report and review of the literature.","volume":"2011","author":"Khasawneh","year":"2011","journal-title":"Case Rep Crit Care"},{"key":"R4-20250504","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1016\/j.bjan.2016.12.004","article-title":"Lost guide wire \u2013 lessons learned.","volume":"68","author":"Alves","year":"2018","journal-title":"Rev Bras Anestesiol"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"1745","DOI":"10.1097\/CCM.0000000000001012","article-title":"Missed central venous guide wires: a systematic analysis of published case reports.","volume":"43","author":"Pokharel","year":"2015","journal-title":"Crit Care Med"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"ytz085","DOI":"10.1093\/ehjcr\/ytz085","article-title":"Aspiration of the guidewire of a central venous jugular catheter by the venous cannula of a veno-arterial extracorporeal membrane oxygenation.","volume":"3","author":"Seguin","year":"2019","journal-title":"Eur Heart J Case Rep"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1097\/00003246-200001000-00023","article-title":"How much guidewire is too much? Direct measurement of the distance from subclavian and internal jugular vein access sites to the superior vena cava-atrial junction during central venous catheter placement.","volume":"28","author":"Andrews","year":"2000","journal-title":"Crit Care Med"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000037638","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T04:03:19Z","timestamp":1746331399000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000037638"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,5]]},"references-count":7,"journal-issue":{"issue":"14","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000037638","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4,5]]}}}