{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T00:06:58Z","timestamp":1747181218640,"version":"3.40.5"},"reference-count":32,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"20","license":[{"start":{"date-parts":[[2024,5,17]],"date-time":"2024-05-17T00:00:00Z","timestamp":1715904000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,5,17]]},"abstract":"<jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>The aim of this study was to compare the biomechanical performance of pedicle screw construction and locking compression plate fixation in posterior pelvic ring injuries analyzed by finite element method.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>A 3-dimensional finite element model of the spine-pelvis-femur complex with ligaments was reconstructed from computed tomography images. An unstable posterior pelvic ring injury was created, which was fixed with a pedicle screw construction or locking compression plate. A follower load of 400\u2009N was applied to the upper surface of the vertebrae to simulate the upper body weight, while the ends of the proximal femurs were fixed. The construct stiffness, the maximum vertical displacement, the maximum posterior displacement, the maximum right displacement, and the overall maximum displacement of the sacrum, and stress distributions of the implants and pelvises were assessed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The construct stiffness of the pedicle screw model (435.14\u2009N\/mm) was 2 times that of the plate model (217.01\u2009N\/mm). The maximum vertical displacement, the maximum posterior displacement, the maximum right displacement, and the overall maximum displacement of the sacrum in the pedicle screw model were smaller than those in the plate model (0.919, 1.299, 0.259, and 1.413\u2009mm in the pedicle screw model, and 1.843, 2.300, 1.053, and 2.895\u2009mm in the plate model, respectively). The peak stresses of the implant and pelvis in the pedicle screw model decreased by 80.4% and 25% when compared with the plate model (44.57 and 34.48\u2009MPa in the pedicle screw model, and 227.47 and 45.97\u2009MPa in the plate model, respectively).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>The study suggested that the pedicle screw construction could provide better fixation stability than the locking compression plate and serves as the recommended fixation method for the treatment of posterior pelvic ring injuries.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000038258","type":"journal-article","created":{"date-parts":[[2024,5,18]],"date-time":"2024-05-18T05:50:34Z","timestamp":1716011434000},"page":"e38258","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Numerical study of pedicle screw construction and locking compression plate fixation in posterior pelvic ring injuries: Analyzed by finite element method"],"prefix":"10.1097","volume":"103","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5672-6693","authenticated-orcid":false,"given":"Jun","family":"Zhang","sequence":"first","affiliation":[{"name":"Department of Orthopaedics, Pudong New Area People\u2019s Hospital, Shanghai, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yan","family":"Wei","sequence":"additional","affiliation":[{"name":"Department of Surgery, Pudong New Area People\u2019s Hospital, Shanghai, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jian","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Pudong New Area People\u2019s Hospital, Shanghai, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Baoqing","family":"Yu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Seventh People\u2019s Hospital Affiliated to Shanghai University of Traditional Chinese Medicine, Shanghai, China."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250503","doi-asserted-by":"crossref","first-page":"S53","DOI":"10.1016\/j.injury.2009.10.037","article-title":"Pelvic ring injuries with haemodynamic instability: efficacy of pelvic packing, a systematic review.","volume":"40","author":"Papakostidis","year":"2009","journal-title":"Injury"},{"key":"R2-20250503","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1097\/00003086-199602000-00028","article-title":"Internal fixation for the transforaminal sacral fracture.","author":"Simonain","year":"1996","journal-title":"Clin Orthop Relat Res"},{"key":"R3-20250503","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.injury.2004.05.029","article-title":"Open pelvic fractures: epidemiology, current concepts of management and outcome.","volume":"36","author":"Grotz","year":"2005","journal-title":"Injury"},{"key":"R4-20250503","doi-asserted-by":"crossref","first-page":"1041","DOI":"10.1016\/j.injury.2023.02.006","article-title":"Management of open pelvic ring injuries.","volume":"54","author":"Roszman","year":"2023","journal-title":"Injury"},{"key":"R5-20250503","doi-asserted-by":"crossref","first-page":"3764","DOI":"10.12659\/MSM.900673","article-title":"Treatment of unstable posterior pelvic ring fracture with pedicle screw-rod fixator versus locking compression plate: a comparative study.","volume":"22","author":"Bi","year":"2016","journal-title":"Med Sci Monit"},{"key":"R6-20250503","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jcot.2015.08.001","article-title":"Pelvic ring injuries: surgical management and long-term outcomes.","volume":"7","author":"Halawi","year":"2016","journal-title":"J Clin Orthop Trauma"},{"key":"R7-20250503","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1111\/os.13585","article-title":"Finite element analysis and transiliac-transsacral screw fixation for posterior pelvic ring with sacrum dysplasia.","volume":"15","author":"Wu","year":"2023","journal-title":"Orthop Surg"},{"key":"R8-20250503","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1007\/s00590-021-03167-x","article-title":"Robot-assisted versus conventional percutaneous sacroiliac screw fixation for posterior pelvic ring injuries: a systematic review and meta-analysis.","volume":"33","author":"Al-Naseem","year":"2023","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"R9-20250503","doi-asserted-by":"crossref","first-page":"101994","DOI":"10.1016\/j.jcot.2022.101994","article-title":"Risk factors for screw breach and iatrogenic nerve injury in percutaneous posterior pelvic ring fixation.","volume":"33","author":"Hadeed","year":"2022","journal-title":"J Clin Orthop Trauma"},{"key":"R10-20250503","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1111\/os.12461","article-title":"Comparative study of percutaneous sacroiliac screw with or without TiRobot assistance for treating pelvic posterior ring fractures.","volume":"11","author":"Long","year":"2019","journal-title":"Orthop Surg"},{"key":"R11-20250503","doi-asserted-by":"crossref","first-page":"1435","DOI":"10.1007\/s00264-009-0756-7","article-title":"Treatment of posterior pelvic ring injuries with minimally invasive percutaneous plate osteosynthesis.","volume":"33","author":"Hao","year":"2009","journal-title":"Int Orthop"},{"key":"R12-20250503","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1097\/BOT.0b013e318158abcf","article-title":"Minimally invasive transiliac plate osteosynthesis for type C injuries of the pelvic ring: a clinical and radiological follow-up.","volume":"21","author":"Krappinger","year":"2007","journal-title":"J Orthop Trauma"},{"key":"R13-20250503","doi-asserted-by":"crossref","first-page":"e0273351","DOI":"10.1371\/journal.pone.0273351","article-title":"Biomechanical study of anterior and posterior pelvic rings using pedicle screw fixation for Tile C1 pelvic fractures: finite element analysis.","volume":"17","author":"Song","year":"2022","journal-title":"PLoS One"},{"key":"R14-20250503","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1007\/s00402-018-3094-7","article-title":"Minimally invasive internal fixator for unstable pelvic ring injuries with a pedicle screw-rod system: a retrospective study of 23 patients after 13.5 months.","volume":"139","author":"Hua","year":"2019","journal-title":"Arch Orthop Trauma Surg"},{"key":"R15-20250503","first-page":"12","article-title":"Development and validation of a numerical model for the mechanical behavior of knee prosthesis analyzed by the finite elements method.","volume":"37","author":"Mestar","year":"2018","journal-title":"J Biomim Biomater Biomed Eng"},{"key":"R16-20250503","doi-asserted-by":"crossref","first-page":"1905","DOI":"10.1007\/s11668-022-01459-w","article-title":"Comparative study of the fractured humerus fixation by intramedullary nailing and compression plate.","volume":"22","author":"Keddar","year":"2022","journal-title":"J Fail Anal Prev"},{"key":"R17-20250503","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1016\/j.compbiomed.2017.06.007","article-title":"Biomechanical study of different fixation techniques for the treatment of sacroiliac joint injuries using finite element analyses and biomechanical tests.","volume":"87","author":"Lee","year":"2017","journal-title":"Comput Biol Med"},{"key":"R18-20250503","doi-asserted-by":"crossref","first-page":"e0201801","DOI":"10.1371\/journal.pone.0201801","article-title":"Effect of the screw type (S2-alar-iliac and iliac), screw length, and screw head angle on the risk of screw and adjacent bone failures after a spinopelvic fixation technique: a finite element analysis.","volume":"13","author":"Shin","year":"2018","journal-title":"PLoS One"},{"key":"R19-20250503","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/j.jocn.2018.03.002","article-title":"Biomechanical characterization of three iliac screw fixation techniques: a finite element study.","volume":"52","author":"Sohn","year":"2018","journal-title":"J Clin Neurosci"},{"key":"R20-20250503","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1097\/00005131-199611000-00001","article-title":"Biomechanical comparison of posterior internal fixation techniques for unstable pelvic fractures.","volume":"10","author":"Comstock","year":"1996","journal-title":"J Orthop Trauma"},{"key":"R21-20250503","doi-asserted-by":"crossref","first-page":"640","DOI":"10.1097\/BOT.0000000000000996","article-title":"Risks to the superior gluteal neurovascular bundle during iliosacral and transsacral screw fixation: a computed tomogram arteriography study.","volume":"31","author":"Maslow","year":"2017","journal-title":"J Orthop Trauma"},{"key":"R22-20250503","doi-asserted-by":"crossref","first-page":"1863","DOI":"10.1007\/s00264-011-1251-5","article-title":"Biomechanical analysis of a transiliac internal fixator.","volume":"35","author":"Dienstknecht","year":"2011","journal-title":"Int Orthop"},{"key":"R23-20250503","first-page":"97","article-title":"Biomechanical comparison of posterior fixation using spinal instrumentation and conventional posterior plate fixation in unstable vertical sacral fracture.","volume":"70","author":"Shinohara","year":"2016","journal-title":"Acta Med Okayama"},{"issue":"Suppl 2","key":"R24-20250503","doi-asserted-by":"crossref","first-page":"12","DOI":"10.2106\/JBJS.J.00780","article-title":"Effects of construct stiffness on healing of fractures stabilized with locking plates.","volume":"92","author":"Bottlang","year":"2010","journal-title":"J Bone Joint Surg Am"},{"key":"R25-20250503","first-page":"39","article-title":"Biomechanical comparison of a transiliac internal fixator and two iliosacral screws in transforaminal sacral fractures: a finite element analysis.","volume":"17","author":"Sal\u00e1\u0161ek","year":"2015","journal-title":"Acta Bioeng Biomech"},{"key":"R26-20250503","doi-asserted-by":"crossref","first-page":"1621","DOI":"10.1016\/S0142-9612(97)00146-4","article-title":"Titanium alloys in total joint replacement \u2013 a materials science perspective.","volume":"19","author":"Long","year":"1998","journal-title":"Biomaterials"},{"key":"R27-20250503","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1177\/0300060517715529","article-title":"Minimally invasive treatment of unstable pelvic ring injuries with modified pedicle screw-rod fixator.","volume":"46","author":"Wu","year":"2018","journal-title":"J Int Med Res"},{"key":"R28-20250503","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1007\/s00264-017-3714-9","article-title":"Minimally invasive stabilisation of posterior pelvic ring instabilities with pedicle screws connected to a transverse rod.","volume":"42","author":"Wang","year":"2018","journal-title":"Int Orthop"},{"key":"R29-20250503","doi-asserted-by":"crossref","first-page":"41","DOI":"10.55095\/achot2015\/005","article-title":"Minimally invasive stabilization of posterior pelvic ring injuries with a transiliac internal fixator and two iliosacral screws: comparison of outcome.","volume":"82","author":"Sal\u00e1\u0161ek","year":"2015","journal-title":"Acta Chir Orthop Traumatol Cech"},{"key":"R30-20250503","doi-asserted-by":"crossref","first-page":"1142","DOI":"10.1007\/s00113-004-0824-9","article-title":"The minimally invasive stabilization of the dorsal pelvic ring with the transiliacal internal fixator (TIFI)--surgical technique and first clinical findings.","volume":"107","author":"F\u00fcchtmeier","year":"2004","journal-title":"Unfallchirurg"},{"key":"R31-20250503","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1097\/00024720-200206000-00005","article-title":"Anatomic and radiographic considerations for placement of transiliac screws in lumbopelvic fixations.","volume":"15","author":"Schildhauer","year":"2002","journal-title":"J Spinal Disord Tech"},{"key":"R32-20250503","doi-asserted-by":"crossref","first-page":"S114","DOI":"10.1016\/S0020-1383(15)30029-2","article-title":"The cement-augmented transiliacal internal fixator (caTIFI): an innovative surgical technique for stabilization of fragility fractures of the pelvis.","volume":"46","author":"Schmitz","year":"2015","journal-title":"Injury"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000038258","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T00:06:13Z","timestamp":1746317173000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000038258"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,17]]},"references-count":32,"journal-issue":{"issue":"20","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000038258","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"type":"print","value":"0025-7974"},{"type":"electronic","value":"1536-5964"}],"subject":[],"published":{"date-parts":[[2024,5,17]]}}}