{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T01:05:43Z","timestamp":1787879143969,"version":"build-2784847793"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"45","license":[{"start":{"date-parts":[[2024,11,8]],"date-time":"2024-11-08T00:00:00Z","timestamp":1731024000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,11,8]]},"abstract":"<jats:p>This study evaluates the diagnostic accuracy of ultrashort echo time (UTE)-MRI for detecting pulmonary nodules and image quality. A total of 46 patients at our hospital underwent unenhanced computed tomography (CT) and UTE-MRI. The image quality and number of nodules detected using CT were used as the gold standards. Three diagnostic radiologists independently recorded the image quality (visibility and sharpness of normal anatomical structures) of the CT and UTE images and the number of pulmonary nodules detected. The diagnostic accuracy, subjective image quality, and consistency between observations were statistically analyzed. Among 46 patients, 36 (78.2%) had pulmonary nodules on CT images, whereas 10 patients (21.7%) had no pulmonary nodules. A total of 48 lung nodules were detected, 3 of which were ground-glass opacities. UTE-MRI revealed 46 lung nodules. Compared with CT, the sensitivity of all MRI readers for detecting lung lesions was 95.8%, and the 3-observer agreement was nearly perfect (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2005&lt;\u2005.001, Kendall W<jats:sup>a<\/jats:sup> [Kender Harmonious Coefficient]\u2005=\u20050.913). The overall image quality score of the observers was high, ranging from good to excellent, and the consistency of the subjective UTE-MRI image quality was good (Kendall W<jats:sup>a<\/jats:sup>\u2005=\u20050.877, <jats:italic toggle=\"yes\">P<\/jats:italic>\u2005&lt;\u2005.001). For tracheal display, the subsegment of the bronchus was displayed, and the wall of the tube was clearly displayed. The difference in the W<jats:sup>a<\/jats:sup> values between the observers was 0.804 (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2005&lt;\u2005.001), indicating strong consistency. For blood vessels, subsegment blood vessels could also be displayed with clear walls and uniform signals (Kendal W<jats:sup>a<\/jats:sup>\u2005=\u20050.823, <jats:italic toggle=\"yes\">P<\/jats:italic>\u2005&lt;\u2005.001), indicating strong consistency. Compared to CT, UTE-MRI can detect pulmonary nodules with a high detection rate, relatively good image quality, and strong consistency between observers. The development of UTE-MRI can provide a novel imaging method for the detection and follow-up of pulmonary nodules and diagnosis of pneumonia by reducing ionizing radiation.<\/jats:p>","DOI":"10.1097\/md.0000000000040386","type":"journal-article","created":{"date-parts":[[2024,11,11]],"date-time":"2024-11-11T20:01:43Z","timestamp":1731355303000},"page":"e40386","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Diagnostic accuracy and image quality evaluation of ultrashort echo time MRI in the lungs"],"prefix":"10.1097","volume":"103","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8475-2247","authenticated-orcid":false,"given":"Funan","family":"Wang","sequence":"first","affiliation":[{"name":"Department of Radiology, Xiamen Branch, Zhongshan Hospital, Fudan University, Xiamen, Fujian, China"},{"name":"Xiamen Municipal Clinical Research Center for Medical Imaging, Xiamen, Fujian, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoxia","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Radiology, Xiamen Branch, Zhongshan Hospital, Fudan University, Xiamen, Fujian, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chong","family":"Lin","sequence":"additional","affiliation":[{"name":"Department of Radiology, Xiamen Branch, Zhongshan Hospital, Fudan University, Xiamen, Fujian, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liuhong","family":"Zhu","sequence":"additional","affiliation":[{"name":"Department of Radiology, Xiamen Branch, Zhongshan Hospital, Fudan University, Xiamen, Fujian, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250504","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1007\/s00117-005-1305-z","article-title":"Visualization of pulmonary nodules with magnetic resonance imaging (MRI).","volume":"46","author":"Plathow","year":"2006","journal-title":"Radiologe"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"2915","DOI":"10.1007\/s00330-015-4125-1","article-title":"Magnetic resonance imaging of pulmonary nodules: accuracy in a granulomatous disease-endemic region.","volume":"26","author":"Henz Concatto","year":"2016","journal-title":"Eur Radiol"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"W210","DOI":"10.2214\/AJR.13.11618","article-title":"MRI of pulmonary nodules.","volume":"202","author":"Kurihara","year":"2014","journal-title":"AJR Am J Roentgenol"},{"key":"R4-20250504","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/j.ejrad.2015.11.020","article-title":"Comparative evaluation of non-contrast CAIPIRINHA-VIBE 3T-MRI and multidetector CT for detection of pulmonary nodules: in vivo evaluation of diagnostic accuracy and image quality.","volume":"85","author":"Dewes","year":"2016","journal-title":"Eur J Radiol"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1016\/j.jtcvs.2008.12.026","article-title":"Is diffusion-weighted magnetic resonance imaging superior to positron emission tomography with fludeoxyglucose F 18 in imaging non-small cell lung cancer.","volume":"138","author":"Ohba","year":"2009","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"1789","DOI":"10.1002\/jmri.26808","article-title":"Ultrashort echo time imaging of the lungs under high-frequency noninvasive ventilation: a new approach to lung imaging.","volume":"50","author":"Bluthgen","year":"2019","journal-title":"J Magn Reson Imaging"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1002\/jmri.26817","article-title":"Can texture analysis in ultrashort echo-time MRI distinguish primary graft dysfunction from acute rejection in lung transplants? A multidimensional assessment in a mouse model.","volume":"51","author":"Euler","year":"2020","journal-title":"J Magn Reso Imaging"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"1208","DOI":"10.1002\/mrm.27998","article-title":"Iterative motion compensation reconstruction ultra-short TE (iMoCo UTE) for high resolution free-breathing pulmonary MRI.","volume":"83","author":"Pipe","year":"2020","journal-title":"Magn Reson Med"},{"key":"R9-20250504","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1148\/radiol.2015150489","article-title":"Detection of small pulmonary nodules with ultrashort echo time sequences in oncology patients by using a PET\/MR System.","volume":"278","author":"Burris Nicholas","year":"2016","journal-title":"Radiology"},{"key":"R10-20250504","doi-asserted-by":"crossref","first-page":"512","DOI":"10.1002\/jmri.25008","article-title":"Pulmonary high-resolution ultrashort TE MR imaging: comparison with thin-section standard- and low-dose computed tomography for the assessment of pulmonary parenchyma diseases.","volume":"43","author":"Ohno","year":"2016","journal-title":"J Magn Reson Imaging"},{"key":"R11-20250504","first-page":"47","article-title":"Pulmonary sub solid nodules: what radiologists need to know about the imaging features and management strategy.","volume":"20","author":"Kim","year":"2014","journal-title":"Diagn Interv Radiol"},{"key":"R12-20250504","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1148\/radiol.09090547","article-title":"Transient part-solid nodules detected on screening thin-section CT for lung cancer: comparison with persistent part-solid nodules.","volume":"255","author":"Lee","year":"2010","journal-title":"Radiology"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"83","DOI":"10.2214\/AJR.11.6862","article-title":"Is there a role for FDG PET in the management of lung cancer manifesting predominantly as ground-glass opacity?","volume":"198","author":"Kim","year":"2012","journal-title":"AJR Am J Roentgenol"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1016\/j.ejrad.2014.11.024","article-title":"Value of diffusion-weighted MR imaging using various parameters for assessment and characterization of solitary pulmonary nodules.","volume":"84","author":"Koyama","year":"2015","journal-title":"Eur J Radiol"},{"key":"R15-20250504","doi-asserted-by":"crossref","first-page":"18","DOI":"10.3389\/fmed.2019.00018","article-title":"MR volumetry of lung nodules: a pilot study.","volume":"6","author":"Delacoste","year":"2019","journal-title":"Front Med"},{"key":"R16-20250504","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1002\/mrm.21620","article-title":"Acquisition-weighted stack of spirals for fast high-resolution three-dimensional ultra-short echo time MR imaging.","volume":"60","author":"Qian","year":"2008","journal-title":"Magn Reson Med"},{"key":"R17-20250504","doi-asserted-by":"crossref","first-page":"1980","DOI":"10.1056\/NEJMoa1209120","article-title":"Results of initial low-dose computed tomographic screening for lung cancer.","volume":"368","author":"Church","year":"2013","journal-title":"N Engl J Med"},{"issue":"Suppl. 2","key":"R18-20250504","doi-asserted-by":"crossref","first-page":"ii1","DOI":"10.1136\/thoraxjnl-2015-207168","article-title":"British Thoracic Society guidelines for the investigation and management of pulmonary nodules.","volume":"70","author":"Callister","year":"2015","journal-title":"Thorax"},{"key":"R19-20250504","doi-asserted-by":"crossref","first-page":"e754","DOI":"10.1016\/S1470-2045(17)30861-6","article-title":"European position statement on lung cancer screening.","volume":"18","author":"Oudkerk","year":"2017","journal-title":"Lancet Oncol"},{"issue":"10, Supplement","key":"R20-20250504","doi-asserted-by":"crossref","first-page":"S185","DOI":"10.1016\/j.jtho.2018.08.012","article-title":"PL02.05 effects of volume CT lung cancer screening: mortality results of the NELSON randomised-controlled population based trial.","volume":"13","author":"De Koning","year":"2018","journal-title":"J Thor Oncol"},{"key":"R21-20250504","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1016\/j.mri.2019.04.015","article-title":"Highresolution lung MRI with ultrashort-TE: 1.5 or 3 tesla?","volume":"61","author":"Chassagnon","year":"2019","journal-title":"Magn Reson Imaging"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000040386","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T01:01:40Z","timestamp":1746320500000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000040386"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,8]]},"references-count":21,"journal-issue":{"issue":"45","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000040386","relation":{},"ISSN":["1536-5964"],"issn-type":[{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,11,8]]}}}