{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T23:42:50Z","timestamp":1787010170518,"version":"build-2736575974"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"45","license":[{"start":{"date-parts":[[2024,11,8]],"date-time":"2024-11-08T00:00:00Z","timestamp":1731024000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,11,8]]},"abstract":"<jats:p>\n                    This study compares the accuracy of SRK\/T and Barrett Universal II intraocular lens (IOL) measurement formulas for cataract phacoemulsification combined with intraocular lens implantation in angle-closure glaucoma (ACG) patients. Prospective serial case studies were conducted. A total of 146 patients (146 eyes) with ACG complicated with cataract who underwent cataract surgery with atrial angle closure \u2264180\u00b0 were observed. All the patients were divided into 2 groups according to different intraocular lens calculation formula, with 73 cases in each group (73 eyes). SRK\/T intraocular lens calculation formula was used in group A, and Barrett intraocular lens calculation formula was used in group B. The visual acuity, the best corrected visual acuity, intraocular pressure and central anterior chamber depth were significantly improved in 146 eyes 3 months after operation, and the differences were statistically significant. There was statistically significant difference in postoperative spherical equivalent (SE) between the 2 groups (\n                    <jats:italic toggle=\"yes\">t<\/jats:italic>\n                    \u2005=\u20052.147,\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    \u2005=\u2005.033), and there was statistically significant difference in preoperative expected refraction between group A and postoperative SE (\n                    <jats:italic toggle=\"yes\">t<\/jats:italic>\n                    \u2005=\u20054.221,\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    \u2005&lt;\u2005.001). There was no significant difference between preoperative expected diopter and postoperative SE in group B (\n                    <jats:italic toggle=\"yes\">t<\/jats:italic>\n                    \u2005=\u20051.857,\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    \u2005=\u2005.065). The difference in absolute predicted error between the 2 groups was statistically significant (\n                    <jats:italic toggle=\"yes\">t<\/jats:italic>\n                    \u2005=\u20054.929,\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    \u2005&lt;\u2005.001). Axis length was negatively correlated with SRK\/T formula and Barrett Universal II formula absolute refractive error value (ME) (group A:\n                    <jats:italic toggle=\"yes\">r<\/jats:italic>\n                    \u2005=\u2005\u20100.740,\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    \u2005&lt;\u2005.001; group B:\n                    <jats:italic toggle=\"yes\">r<\/jats:italic>\n                    \u2005=\u2005\u20100.532,\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    \u2005&lt;\u2005.001), there was A significant negative correlation between absolute refractive error value and anterior chamber depth in both groups (group A:\n                    <jats:italic toggle=\"yes\">r<\/jats:italic>\n                    \u2005=\u2005\u20100.382,\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    \u2005=\u2005.001; group B:\n                    <jats:italic toggle=\"yes\">r<\/jats:italic>\n                    \u2005=\u2005\u20100.358,\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    \u2005=\u2005.002). The cataract phacoemulsification combined with intraocular lens implantation is safe and effective for ACG patients with cataract. For such patients, the Barrett Universal II intraocular lens measurement formula may be more accurate after surgery.\n                  <\/jats:p>","DOI":"10.1097\/md.0000000000040387","type":"journal-article","created":{"date-parts":[[2024,11,11]],"date-time":"2024-11-11T15:01:40Z","timestamp":1731337300000},"page":"e40387","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["Comparison of two formulas for calculating intraocular lens in patients with angle-closure glaucoma"],"prefix":"10.1097","volume":"103","author":[{"given":"Zhen","family":"Ji","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, The Second People\u2019s Hospital of Jinan, Jinan, PR China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jing","family":"Ma","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, The Second People\u2019s Hospital of Jinan, Jinan, PR China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhonghua","family":"Sun","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, The Second People\u2019s Hospital of Jinan, Jinan, PR China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9631-4551","authenticated-orcid":false,"given":"Miaomiao","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, The Second People\u2019s Hospital of Jinan, Jinan, PR China."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250504","first-page":"435","article-title":"Enhancing intraocular lens outcome precision: an evaluation of axial length determinations, keratometry, and IOL formulas.","volume":"19","author":"Prager","year":"2006","journal-title":"Ophthalmol Clin North Am"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1016\/S0886-3350(13)80338-0","article-title":"The Hoffer Q formula: a comparison of theoretic and regression formulas.","volume":"19","author":"Hoffer","year":"1993","journal-title":"J Cataract Refract Surg"},{"key":"R3-20250504","first-page":"807","article-title":"Analysis of changes in anterior chamber depth after intraocular lens implantation.","volume":"9","author":"Feng","year":"2007","journal-title":"Zhejiang Clin Med"},{"key":"R4-20250504","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1111\/j.1755-3768.2007.00879.x","article-title":"Calculation of intraocular lens power: a review.","volume":"85","author":"Thomas","year":"2007","journal-title":"Acta Ophthalmol Scand"},{"key":"R5-20250504","first-page":"337","article-title":"The latest technology of refractive surgery and its clinical application.","volume":"20","author":"Huang","year":"2007","journal-title":"J Med Postgrad"},{"key":"R6-20250504","first-page":"37","article-title":"A comparison of letrozole and anastrozole followed by letrozole in breast cancer patients.","volume":"20","author":"Aphinives","year":"2015","journal-title":"Breast Cancer"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1055\/s-0043-110569","article-title":"Interpretation of the intraocular lens constants for the Haigis formula.","volume":"234","author":"Schr\u00f6der","year":"2017","journal-title":"Klin Monbl Augenheilkd"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"678","DOI":"10.1007\/s10384-023-01021-7","article-title":"Lens factor as an underlying mechanism in primary angle closure with gonioscopically-visualized ciliary body processes.","volume":"67","author":"Tekcan","year":"2023","journal-title":"Jpn J Ophthalmol"},{"key":"R9-20250504","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1007\/s10103-023-03772-8","article-title":"Factors defining the intraocular pressure-lowering effect of phacoemulsification and laser peripheral iridotomy in patients with primary angle closure: factors defining IOP lowering effect of PE and LPI in PAC.","volume":"38","author":"Un","year":"2023","journal-title":"Lasers Med Sci"},{"key":"R10-20250504","first-page":"355","article-title":"Preliminary clinical study on the management of angle-closure glaucoma by phacoemulsification with foldable posterior chamber intraocular lens implantation.","volume":"37","author":"Ge","year":"2001","journal-title":"Chin J Ophthalmol"},{"key":"R11-20250504","first-page":"17","article-title":"Multi-centre trial of phacoemulsification on patients with primary angle-closure glaucoma and co-existing cataract.","volume":"39","author":"Song","year":"2010","journal-title":"J Med Res"},{"key":"R12-20250504","doi-asserted-by":"crossref","first-page":"892","DOI":"10.1016\/j.jcrs.2017.07.004","article-title":"Intraocular lens power calculations in short eyes using 7 formulas.","volume":"43","author":"G\u00f6kce","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"R13-20250504","first-page":"361","article-title":"Observation of the effect of axial changes on intraocular lens diopter after glaucoma filtration surgery.","volume":"20","author":"Li","year":"2002","journal-title":"Eye Res"},{"key":"R14-20250504","first-page":"455","article-title":"Axial changes and intraocular lens power calculation after glaucoma filtration.","volume":"25","author":"Liao","year":"2005","journal-title":"J Gannan Med Coll"},{"key":"R15-20250504","first-page":"34","article-title":"The clinical trial studies about the influence of IOL diopter calculation results after glaucoma filtration surgery.","volume":"15","author":"Li","year":"2015","journal-title":"World Latest Med Inform (Electronic Version c)"},{"key":"R16-20250504","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2020\/7625725","article-title":"Comparison of predictability using Barrett Universal II and SRK\/T formulas according to keratometry.","volume":"2020","author":"Iijima","year":"2020","journal-title":"J Ophthalmol"},{"key":"R17-20250504","first-page":"68","article-title":"Comparison of two intraocular lens measurement formulas for prediction of postoperative refraction accuracy in patients with angle closure glaucoma and cataract.","volume":"32","author":"Gao","year":"2018","journal-title":"J Otolaryngol Ophthalmol Shandong Univ"},{"key":"R18-20250504","doi-asserted-by":"crossref","first-page":"976847","DOI":"10.1155\/2015\/976847","article-title":"Accuracy of intraocular lens power formulas involving 148 eyes with long axial lengths: a retrospective chart-review study.","volume":"2015","author":"Chen","year":"2015","journal-title":"J Ophthalmol"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000040387","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,3]],"date-time":"2025-05-03T21:01:36Z","timestamp":1746306096000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000040387"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,8]]},"references-count":18,"journal-issue":{"issue":"45","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000040387","relation":{},"ISSN":["1536-5964"],"issn-type":[{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,11,8]]}}}