{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,19]],"date-time":"2026-06-19T06:52:59Z","timestamp":1781851979463,"version":"3.54.5"},"reference-count":31,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"45","license":[{"start":{"date-parts":[[2024,11,8]],"date-time":"2024-11-08T00:00:00Z","timestamp":1731024000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"the Foundation of Zhejiang Provincial Education Department","award":["Y202249357"],"award-info":[{"award-number":["Y202249357"]}]},{"name":"the Science and Technology Program of the Yiwu Science and Technology Bureau","award":["20-3-218"],"award-info":[{"award-number":["20-3-218"]}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,11,8]]},"abstract":"<jats:p>This study presents an in-depth exploration of various adjustment methods for intraoperative catheter malposition by guidewires in the implantation of totally implantable venous access ports (TIVAP). It not only aims to summarize these methods but also endeavors to identify the most advantageous approach. The patient list was searched using the hospital information system from January 1, 2022, to October 31, 2023. All patients who had undergone chest port placement using the axillary vein (AxV) or subclavian vein (SCV) approach were reviewed, and further imaging was performed to confirm the guidewire applied to adjust the guidewire or catheter from the internal jugular vein into the superior vena cava (SVC) under fluoroscopy. Demographic data, diagnoses, technical outcomes, and perioperative complications were collected. About 32 patients with an average age of 62.8 years were included in the study. The operation time was 29.3\u2005\u00b1\u200513.3 minutes and SVC selecting time was 16.9\u2005\u00b1\u200511.5 seconds. The dose of X-ray exposure was only 7.2\u2005\u00b1\u20059.0 \u03bcGym<jats:sup>2<\/jats:sup>. Adjustments combined the guidewire with the puncture needle had the shortest SVC selection time and operation time with a minimal radiation dose. intraoperative catheter malposition can be timely and effectively adjusted using guidewires under fluoroscopy during any process of TIVAP implantation. Timely adjustment using a guidewire after inserting into the puncture needle is an optimal choice for a smooth and successful operation.<\/jats:p>","DOI":"10.1097\/md.0000000000040461","type":"journal-article","created":{"date-parts":[[2024,11,11]],"date-time":"2024-11-11T20:02:27Z","timestamp":1731355347000},"page":"e40461","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["The utilization of guidewires for adjusting the intraoperative catheter malposition during the venous access port implantation: A retrospective study"],"prefix":"10.1097","volume":"103","author":[{"given":"Li","family":"Zhang","sequence":"first","affiliation":[{"name":"Department of Nephrology, The Fourth Affiliated Hospital of School of Medicine, and International School of Medicine, International Institutes of Medicine, Zhejiang University, Yiwu, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9680-7524","authenticated-orcid":false,"given":"Jingjin","family":"Wu","sequence":"additional","affiliation":[{"name":"Department of General Surgery, The Fourth Affiliated Hospital of School of Medicine, and International School of Medicine, International Institutes of Medicine, Zhejiang University, Yiwu, China."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250504","first-page":"706","article-title":"Totally implanted venous and arterial access system to replace external catheters in cancer treatment.","volume":"92","author":"Niederhuber","year":"1982","journal-title":"Surgery"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"1184","DOI":"10.1016\/j.jvsv.2022.03.007","article-title":"A systematic review and network meta-analysis of randomized controlled trials on choice of central venous access device for delivery of chemotherapy.","volume":"10","author":"Yeow","year":"2022","journal-title":"J Vasc Surg Venous Lymphatic Disord"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1023\/A:1008392423469","article-title":"Totally implantable central venous access ports for long-term chemotherapy. A prospective study analyzing complications and costs of 333 devices with a minimum follow-up of 180 days.","volume":"9","author":"Biffi","year":"1998","journal-title":"Ann Oncol"},{"key":"R4-20250504","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1186\/s12885-022-09228-6","article-title":"Comparison of comfort and complications of implantable venous access port (IVAP) with ultrasound guided internal jugular vein (IJV) and axillary vein\/subclavian vein (AxV\/SCV) puncture in breast cancer patients: a randomized controlled study.","volume":"22","author":"Chen","year":"2022","journal-title":"BMC cancer"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1186\/s12885-016-2791-2","article-title":"Internal jugular vein versus subclavian vein as the percutaneous insertion site for totally implantable venous access devices: a meta-analysis of comparative studies.","volume":"16","author":"Wu","year":"2016","journal-title":"BMC Cancer"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"e37","DOI":"10.1097\/CCM.0000000000005740","article-title":"Ultrasound-guided infraclavicular axillary vein versus internal jugular vein cannulation in critically ill mechanically ventilated patients: a randomized trial.","volume":"51","author":"Czarnik","year":"2023","journal-title":"Crit Care Med"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1111\/j.1365-2044.1987.tb02988.x","article-title":"A new percutaneous infraclavicular approach to the axillary vein.","volume":"42","author":"Nickalls","year":"1987","journal-title":"Anaesthesia"},{"key":"R8-20250504","doi-asserted-by":"crossref","first-page":"1439","DOI":"10.1016\/j.jvir.2013.12.571","article-title":"A single-incision technique for placement of implantable venous access ports via the axillary vein.","volume":"25","author":"Seo","year":"2014","journal-title":"J Vasc Interv Radiol"},{"key":"R9-20250504","doi-asserted-by":"crossref","first-page":"706","DOI":"10.1177\/11297298211008094","article-title":"Single center experience with ultrasound guided axillary vein port placement.","volume":"23","author":"Tivnan","year":"2022","journal-title":"J Vasc Access"},{"key":"R10-20250504","doi-asserted-by":"crossref","first-page":"4323","DOI":"10.21037\/apm-20-1752","article-title":"Comparison of comfort and complications in breast cancer patients of implantable venous access port (IVAP) with ultrasound guided internal jugular vein (IJV) and axillary vein\/subclavian vein (AxV\/SCV) puncture: a randomized controlled study protocol.","volume":"9","author":"Chen","year":"2020","journal-title":"Ann Palliat Med"},{"key":"R11-20250504","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1093\/bja\/aes497","article-title":"Misplaced central venous catheters: applied anatomy and practical management.","volume":"110","author":"Gibson","year":"2013","journal-title":"Br J Anaesth"},{"key":"R12-20250504","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1111\/ijn.12154","article-title":"Malposition of peripherally inserted central catheter: experience from 3012 cancer patients.","volume":"20","author":"Song","year":"2014","journal-title":"Int J Nurs Pract"},{"key":"R13-20250504","doi-asserted-by":"crossref","first-page":"738","DOI":"10.1097\/EJA.0000000000001064","article-title":"Guidewire-assisted vs. direct radial arterial cannulation in neonates and infants: A randomised controlled trial.","volume":"36","author":"Jang","year":"2019","journal-title":"Eur J Anaesthesiol"},{"key":"R14-20250504","doi-asserted-by":"crossref","first-page":"530","DOI":"10.5301\/jva.5000763","article-title":"A Randomized comparison between an intravenous catheter system with a retractable guidewire and conventional intravenous catheters.","volume":"18","author":"Chick","year":"2017","journal-title":"J Vasc Access"},{"key":"R15-20250504","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1097\/EJA.0000000000001695","article-title":"Straight-tip guidewire versus J-tip guidewire for central venous catheterisation in neonates and small infants: a randomised controlled trial.","volume":"39","author":"Kim","year":"2022","journal-title":"Eur J Anaesthesiol"},{"key":"R16-20250504","doi-asserted-by":"crossref","first-page":"3517","DOI":"10.3748\/wjg.v26.i25.3517","article-title":"Chinese expert consensus and practice guideline of totally implantable access port for digestive tract carcinomas.","volume":"26","author":"Zhang","year":"2020","journal-title":"World J Gastroenterol"},{"issue":"Suppl 5","key":"R17-20250504","doi-asserted-by":"crossref","first-page":"v152","DOI":"10.1093\/annonc\/mdv296","article-title":"Central venous access in oncology: ESMO Clinical Practice Guidelines.","volume":"26","author":"Sousa","year":"2015","journal-title":"Ann Oncol"},{"key":"R18-20250504","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1177\/02683555211069772","article-title":"Totally implantable venous access ports: a systematic review and meta-analysis comparing subclavian and internal jugular vein punctures.","volume":"37","author":"Zhou","year":"2022","journal-title":"Phlebology"},{"key":"R19-20250504","doi-asserted-by":"crossref","first-page":"345","DOI":"10.5301\/jva.5000751","article-title":"Long-term clinical outcomes of the single-incision technique for implantation of implantable venous access ports via the axillary vein.","volume":"18","author":"Seo","year":"2017","journal-title":"J Vasc Access"},{"key":"R20-20250504","doi-asserted-by":"crossref","first-page":"935","DOI":"10.1093\/annonc\/mdn701","article-title":"Best choice of central venous insertion site for the prevention of catheter-related complications in adult patients who need cancer therapy: a randomized trial.","volume":"20","author":"Biffi","year":"2009","journal-title":"Ann Oncol"},{"key":"R21-20250504","doi-asserted-by":"crossref","first-page":"157","DOI":"10.23736\/S0375-9393.19.13670-X","article-title":"Ultrasound-guided central venous catheter placement through the axillary vein in cardiac critical care patients: safety and feasibility of a novel technique in a prospective observational study.","volume":"86","author":"Farina","year":"2020","journal-title":"Minerva Anestesiol"},{"key":"R22-20250504","doi-asserted-by":"crossref","first-page":"1275","DOI":"10.21873\/invivo.11377","article-title":"Catheter-related complications of subcutaneous implantable venous access devices in breast cancer patients.","volume":"32","author":"El-Balat","year":"2018","journal-title":"In Vivo"},{"key":"R23-20250504","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1186\/s12957-016-1002-6","article-title":"Application and comparison of different implanted ports in malignant tumor patients.","volume":"14","author":"Li","year":"2016","journal-title":"World J Surg Oncol"},{"key":"R24-20250504","doi-asserted-by":"crossref","first-page":"499","DOI":"10.5606\/tgkdc.dergisi.2019.17972","article-title":"Complications and management strategies of totally implantable venous access port insertion through percutaneous subclavian vein.","volume":"27","author":"Velio\u011flu","year":"2019","journal-title":"Turk gogus kalp damar cerrahisi dergisi"},{"key":"R25-20250504","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1016\/j.jvir.2007.01.020","article-title":"Analysis of tip malposition and correction in peripherally inserted central catheters placed at bedside by a dedicated nursing team.","volume":"18","author":"Trerotola","year":"2007","journal-title":"J Vasc Interv Radiol"},{"key":"R26-20250504","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1177\/0148607107031005382","article-title":"Tip position of long-term central venous access devices used for parenteral nutrition.","volume":"31","author":"DeChicco","year":"2007","journal-title":"JPEN J Parenter Enteral Nutr"},{"key":"R27-20250504","doi-asserted-by":"crossref","first-page":"42","DOI":"10.4103\/ijn.IJN_14_18","article-title":"Iatrogenic central vein perforation: a nonsurgical therapeutic approach.","volume":"29","author":"Singh","year":"2019","journal-title":"Indian J Nephrol"},{"key":"R28-20250504","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1093\/rpd\/nct304","article-title":"Overview of the ICRP\/ICRU adult reference computational phantoms and dose conversion coefficients for external idealised exposures.","volume":"161","author":"Endo","year":"2013","journal-title":"Radiat Prot Dosim"},{"key":"R29-20250504","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1097\/HP.0000000000001118","article-title":"Trends and distribution analysis of occupational exposure from medical practices in China (2010\u20132016).","volume":"117","author":"Deng","year":"2019","journal-title":"Health Phys"},{"key":"R31-20250504","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1088\/0952-4746\/21\/1\/609","article-title":"UNSCEAR Report 2000: sources and effects of ionizing radiation.","volume":"21","author":"Charles","year":"2001","journal-title":"J Radiol Protect"},{"key":"R32-20250504","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1007\/s11547-016-0709-3","article-title":"Radiation exposure in diagnostic imaging: wisdom and prudence, but still a lot to understand.","volume":"122","author":"Tom\u00e0","year":"2016","journal-title":"Radiol Med"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000040461","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T01:01:07Z","timestamp":1746320467000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000040461"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,8]]},"references-count":31,"journal-issue":{"issue":"45","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000040461","relation":{},"ISSN":["1536-5964"],"issn-type":[{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,11,8]]}}}