{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T04:07:50Z","timestamp":1746331670560,"version":"3.40.4"},"reference-count":8,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"49","license":[{"start":{"date-parts":[[2024,12,6]],"date-time":"2024-12-06T00:00:00Z","timestamp":1733443200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,12,6]]},"abstract":"<jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>This study aimed to report and recall a simple method to remove the lens capsule ab externo when performing intrascleral fixation of an intracapsular intraocular lens (IOL) dislocation with reuse of the IOL.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Case presentation:<\/jats:title>\n            <jats:p>A 43-year-old Japanese male patient underwent pars plana vitrectomy, phacoemulsification, and IOL fixation for rhegmatogenous retinal detachment in the right eye 10 years prior. A 3-piece IOL was intraocularly fixed during the initial procedure. In December 2023, the patient presented with intracapsular IOL dislocation in his right eye, causing the IOL to descend into the vitreous cavity enveloped by its entire capsule. During surgery, an intravitreal dislocated IOL was placed over the iris with the entire capsule. The haptics on 1 side of the IOL were placed outside the eye through the corneoscleral wound. Subsequently, the lens capsule and Soemmerring\u2019s ring surrounding the haptics were removed. After the haptics were placed back over the iris, the same extraction procedure was performed for the remaining haptics. The IOL was intrasclerally fixed using a flange technique through the intrascleral tunnel at the 4 and 10 o\u2019clock positions. One week postsurgery, the best-corrected visual acuity of the right eye was 20\/16, and the corneal endothelial cell density was recorded as 2923 cells\/mm<jats:sup>2<\/jats:sup> (preoperative: 1650 cells\/mm<jats:sup>2<\/jats:sup>).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Discussion and conclusions:<\/jats:title>\n            <jats:p>In cases of 3-piece IOL dislocation, employing the ab externo technique for lens capsule extraction has been proven to be a straightforward and efficient method. This approach facilitates the removal of the lens capsule around the IOL. If subsequent damage to the IOL is identified, it allows for easy conversion to replacement.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000040840","type":"journal-article","created":{"date-parts":[[2024,12,9]],"date-time":"2024-12-09T21:01:02Z","timestamp":1733778062000},"page":"e40840","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Simple ab externo lens capsule removal in intraocular lens reuse and intrascleral fixation for intracapsular lens dislocation: A case report"],"prefix":"10.1097","volume":"103","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9938-4881","authenticated-orcid":false,"given":"Suguru","family":"Nakagawa","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Saitama Red Cross Hospital, Saitama, Japan"},{"name":"Department of Ophthalmology, Saitama Medical Center, Jichi Medical University, Saitama, Japan."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kiyoshi","family":"Ishii","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Saitama Red Cross Hospital, Saitama, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250504","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1007\/s10792-024-03166-x","article-title":"Background factors determining the time to intraocular lens dislocation.","volume":"44","author":"Nakagawa","year":"2024","journal-title":"Int Ophthalmol"},{"key":"R2-20250504","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.jfo.2019.06.013","article-title":"Comparative evaluation of re-use or replacement of dislocated 3-piece intraocular lenses with a scleral fixation technique.","volume":"43","author":"Besek","year":"2020","journal-title":"J Fr Ophtalmol"},{"key":"R3-20250504","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1016\/j.ophtha.2016.10.024","article-title":"Late in-the-bag intraocular lens dislocation: a randomized clinical trial comparing lens repositioning and lens exchange.","volume":"124","author":"Kristianslund","year":"2017","journal-title":"Ophthalmology"},{"key":"R4-20250504","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/j.jcrs.2005.06.050","article-title":"Ab externo scleral suture loop fixation for posterior chamber intraocular lens decentration: clinical results.","volume":"32","author":"Chan","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"R5-20250504","doi-asserted-by":"crossref","first-page":"1450","DOI":"10.1097\/IAE.0000000000000484","article-title":"Surgical outcome of simultaneous intraocular lens rescue and sutureless intrascleral tunnel fixation of dislocated intraocular lenses.","volume":"35","author":"Kim","year":"2015","journal-title":"Retina"},{"key":"R6-20250504","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2018\/7342917","article-title":"Comparisons of visual and surgical outcomes after reuse or replacement of dislocated in-the-Bag intraocular lens.","volume":"2018","author":"Baba","year":"2018","journal-title":"J Ophthalmol"},{"key":"R7-20250504","doi-asserted-by":"crossref","first-page":"1136","DOI":"10.1016\/j.ophtha.2017.03.036","article-title":"Flanged intrascleral intraocular lens fixation with double-needle technique.","volume":"124","author":"Yamane","year":"2017","journal-title":"Ophthalmology"},{"key":"R8-20250504","first-page":"e70688","article-title":"Secondary intrascleral intraocular lens fixation with lens capsule preservation for aphakic eyes in patients with pseudoexfoliation syndrome: a case series.","volume":"16","author":"Nakagawa","year":"2024","journal-title":"Cureus"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000040840","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T01:02:25Z","timestamp":1746320545000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000040840"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,6]]},"references-count":8,"journal-issue":{"issue":"49","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000040840","relation":{},"ISSN":["1536-5964"],"issn-type":[{"type":"electronic","value":"1536-5964"}],"subject":[],"published":{"date-parts":[[2024,12,6]]}}}