{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,26]],"date-time":"2025-08-26T06:57:41Z","timestamp":1756191461244,"version":"3.33.0"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2025,1,17]],"date-time":"2025-01-17T00:00:00Z","timestamp":1737072000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,1,17]]},"abstract":"<jats:p>Anterior cruciate ligament reconstruction aims to improve knee stability and range of motion. The AperFix system consists of polymer components, and fixed-loop fixation is an established endoscopic technique. Our aim in this study was to compare the long-term clinical and radiological results of AperFix and fixed-loop fixation and to prove that the long-term results of the AperFix fixation method are at least as good as those of the fixed loop device. This retrospective study included 109 patients who underwent primary anterior cruciate ligament reconstruction using single bundled hamstring tendon grafts. Patients under 16 years of age, patients with incomplete follow-up, bilateral or other ligament injuries, inflammatory arthropathy, previous knee surgery, or concurrent meniscal treatment were excluded. Participants were divided into 2 groups according to femoral fixation methods: AperFix fixation (group 1, n\u2005=\u200555) and fixed loop device fixation (group 2, n\u2005=\u200554). All operations were performed by senior surgeons under general or spinal anesthesia. Postoperative rehabilitation started on day 1 and allowed patients to resume normal activities at 6 months. Outcomes were evaluated during follow-up, including knee range of motion, clinical scores [Lysholm, Cincinnati, Tegner, and International Knee Documentation Committee] and radiographic measurements of femoral tunnel width and length. Measurements were performed by 2 orthopedic surgeons to ensure reliability. This study evaluated 109 patients (55 in group 1, 54 in group 2) and found no statistically significant differences in demographic variables such as age, sex, body mass index, follow-up duration, or side distribution. Clinical outcomes, including anterior drawer test, Lachman test results, knee flexion-extension degrees, and Lysholm, Cincinnati, Tegner, and International Knee Documentation Committee scores, were similar between the groups (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2005&gt;\u2005.05). Complications occurred in 8 cases (rerupture, infection, and deep vein thrombosis), with no significant correlation to the fixation method used (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2005=\u2005.506). Radiographic analysis revealed no significant differences in femoral tunnel width or length between the groups (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2005&gt;\u2005.05). In our current study, no meaningful disparity was found between the AperFix and fixed loop device methods in terms of long-term clinical outcomes. As there are no long-term studies on the results of AperFix fixation in the literature, more studies on this subject are needed.<\/jats:p>","DOI":"10.1097\/md.0000000000041199","type":"journal-article","created":{"date-parts":[[2025,1,21]],"date-time":"2025-01-21T03:02:50Z","timestamp":1737428570000},"page":"e41199","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Comparison of long-term clinical and radiologic outcomes of AperFix and fixed loop device fixation in anterior cruciate ligament reconstruction: A retrospective study"],"prefix":"10.1097","volume":"104","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9636-5260","authenticated-orcid":false,"given":"Sehmuz","family":"Kaya","sequence":"first","affiliation":[{"name":"Department of Orthopaedics and Traumatology, Faculty of Medicine, Van Yuzuncu Yil University, Van, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0363-1524","authenticated-orcid":false,"given":"Necip","family":"Guven","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Traumatology, Faculty of Medicine, Van Yuzuncu Yil University, Van, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-6733-4211","authenticated-orcid":false,"given":"Yunus Can","family":"Unal","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Traumatology, Van Education And Research Hospital, Van, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4444-6939","authenticated-orcid":false,"given":"Sezai","family":"Ozkan","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Traumatology, Faculty of Medicine, Van Yuzuncu Yil University, Van, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3652-6077","authenticated-orcid":false,"given":"Cihan","family":"Adanas","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Traumatology, Faculty of Medicine, Van Yuzuncu Yil University, Van, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0966-9080","authenticated-orcid":false,"given":"Tulin","family":"Turkozu","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Traumatology, Faculty of Medicine, Van Yuzuncu Yil University, Van, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3543-0479","authenticated-orcid":false,"given":"Ferhat","family":"Danisman","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Traumatology, Van Education And Research Hospital, Van, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4759-3969","authenticated-orcid":false,"given":"Ulan","family":"Ismailov","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Traumatology, Sanliurfa Education And Research Hospital, Sanliurfa, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2617-2073","authenticated-orcid":false,"given":"Abdulrahim","family":"Dundar","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Traumatology, Faculty of Medicine, Hitit University, Corum, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7958-7235","authenticated-orcid":false,"given":"Zulkuf","family":"Akdemir","sequence":"additional","affiliation":[{"name":"Department of Radiology, Faculty of Medicine, Van Yuzuncu Yil University, Van, Turkey."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0317-7365","authenticated-orcid":false,"given":"Mehmet Ata","family":"Gokalp","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Traumatology, Faculty of Medicine, Van Yuzuncu Yil University, Van, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250121","doi-asserted-by":"crossref","first-page":"39","DOI":"10.55095\/achot2021\/007","article-title":"Rotational stability of the knee joint 2 years after the anterolateral ligament and ACL reconstruction: biomechanical study.","volume":"88","author":"Komzak","year":"2021","journal-title":"Acta Chir Orthop Traumatol Cech"},{"key":"R2-20250121","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1177\/2325967120931097","article-title":"Treatment after anterior cruciate ligament injury: panther symposium ACL treatment consensus group.","volume":"8","author":"Diermeier","year":"2020","journal-title":"Orthop J Sports Med"},{"key":"R3-20250121","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1177\/19417381231184427","article-title":"Factors associated with awareness, adoption, and implementation of anterior cruciate ligament injury prevention in youth sports.","volume":"16","author":"MacFarlane","year":"2024","journal-title":"Sports health"},{"key":"R5-20250121","doi-asserted-by":"crossref","first-page":"e33091","DOI":"10.1097\/MD.0000000000033091","article-title":"Clinical outcomes in dynamic intraligamentary stabilization technique for anterior cruciate ligament tear: a meta-analysis.","volume":"102","author":"Meng","year":"2023","journal-title":"Medicine (Baltimore)"},{"key":"R6-20250121","doi-asserted-by":"crossref","first-page":"10225536241293538","DOI":"10.1177\/10225536241293538","article-title":"Use of tourniquet in anterior cruciate ligament reconstruction: is it truly necessary? A prospective randomized clinical trial.","volume":"32","author":"D\u2019Ambrosi","year":"2024","journal-title":"J Orthop Surg (Hong Kong)"},{"key":"R7-20250121","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/j.knee.2015.04.004","article-title":"Evaluation and comparison of clinical results of femoral fixation devices in arthroscopic anterior cruciate ligament reconstruction.","volume":"23","author":"Aydin","year":"2016","journal-title":"Knee"},{"key":"R8-20250121","doi-asserted-by":"crossref","first-page":"e1155","DOI":"10.1016\/j.asmr.2021.05.003","article-title":"No difference in outcomes between suspensory (fixed-loop cortical button) versus expandable anteromedial femoral fixation in anterior cruciate ligament reconstruction with autologous hamstring tendons: a prospective, randomized, controlled study in male patients.","volume":"3","author":"Panagopoulos","year":"2021","journal-title":"Arthrosc Sports Med Rehabil"},{"key":"R9-20250121","doi-asserted-by":"crossref","first-page":"2484","DOI":"10.1016\/j.arthro.2019.02.029","article-title":"Fixed-versus adjustable-loop devices for femoral fixation in anterior cruciate ligament reconstruction: a systematic review.","volume":"35","author":"Onggo","year":"2019","journal-title":"Arthroscopy"},{"key":"R10-20250121","first-page":"42","article-title":"Randomized comparative study of suspension femoral fixation device in graft position maintenance in anterior cruciate ligament reconstruction: EndoButton CL vs TightRope RT.","volume":"25","author":"Ono","year":"2021","journal-title":"Asia Pac J Sports Med Arthrosc Rehabil Technol"},{"key":"R11-20250121","doi-asserted-by":"crossref","first-page":"e159","DOI":"10.3928\/01477447-20130122-17","article-title":"Two-year outcome with the AperFix system for ACL reconstruction.","volume":"36","author":"Uribe","year":"2013","journal-title":"Orthopedics"},{"key":"R12-20250121","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/j.clinbiomech.2012.12.007","article-title":"Biomechanical comparison of femoral fixation devices for anterior cruciate ligament reconstruction using a novel testing method.","volume":"28","author":"Ehrensberger","year":"2013","journal-title":"Clin Biomech (Bristol)"},{"key":"R13-20250121","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1001\/archfaci.11.1.53","article-title":"Use of customized polyetheretherketone (PEEK) implants in the reconstruction of complex maxillofacial defects.","volume":"11","author":"Kim","year":"2009","journal-title":"Arch Facial Plast Surg"},{"key":"R14-20250121","doi-asserted-by":"crossref","first-page":"4845","DOI":"10.1016\/j.biomaterials.2007.07.013","article-title":"PEEK biomaterials in trauma, orthopedic, and spinal implants.","volume":"28","author":"Kurtz","year":"2007","journal-title":"Biomaterials"},{"key":"R15-20250121","doi-asserted-by":"crossref","first-page":"962","DOI":"10.1177\/0363546508330145","article-title":"Biomechanical comparison of single-tunnel-double-bundle and single-bundle anterior cruciate ligament reconstructions.","volume":"37","author":"Gadikota","year":"2009","journal-title":"Am J Sports Med"},{"key":"R16-20250121","doi-asserted-by":"crossref","first-page":"e654","DOI":"10.3928\/01477447-20120426-18","article-title":"Effect of PEEK polymer on tunnel widening after hamstring ACL reconstruction.","volume":"35","author":"Uzumcugil","year":"2012","journal-title":"Orthopedics"},{"key":"R17-20250121","doi-asserted-by":"crossref","first-page":"23259671241228543","DOI":"10.1177\/23259671241228543","article-title":"Validity of material related to the anterior cruciate ligament on TikTok.","volume":"12","author":"D\u2019Ambrosi","year":"2024","journal-title":"Orthop J Sports Med"},{"key":"R18-20250121","doi-asserted-by":"crossref","first-page":"2277","DOI":"10.1177\/0363546517717672","article-title":"Cortical button versus cross-pin femoral fixation for hamstring anterior cruciate ligament reconstruction: a meta-analysis of randomized controlled trials.","volume":"46","author":"Jiang","year":"2018","journal-title":"Am J Sports Med"},{"key":"R19-20250121","doi-asserted-by":"crossref","first-page":"e0275097","DOI":"10.1371\/journal.pone.0275097","article-title":"Femoral fixation methods for hamstring graft in anterior cruciate ligament reconstruction: a network meta-analysis of controlled clinical trials.","volume":"17","author":"Nie","year":"2022","journal-title":"PLoS One"},{"key":"R20-20250121","doi-asserted-by":"crossref","first-page":"1850","DOI":"10.1007\/s00167-020-06231-x","article-title":"Interference screws are more likely to perform better than cortical button and cross-pin fixation for hamstring autograft in ACL reconstruction: a Bayesian network meta-analysis.","volume":"29","author":"Yan","year":"2021","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"R21-20250121","doi-asserted-by":"crossref","first-page":"1953","DOI":"10.1016\/j.arthro.2020.04.023","article-title":"Comparative risk-benefit profiles of individual devices for graft fixation in anterior cruciate ligament reconstruction: a systematic review and network meta-analysis.","volume":"36","author":"Wang","year":"2020","journal-title":"Arthroscopy"},{"key":"R22-20250121","first-page":"444","article-title":"Comparison of different methods of femoral fixation anterior cruciate ligament reconstruction.","volume":"51","author":"Eajazi","year":"2013","journal-title":"Acta Med Iran"},{"key":"R23-20250121","doi-asserted-by":"crossref","first-page":"150","DOI":"10.4103\/0019-5413.152436","article-title":"Outcome of transtibial AperFix system in anterior cruciate ligament injuries.","volume":"49","author":"G\u00f6rmeli","year":"2015","journal-title":"Indian J Orthop"},{"key":"R24-20250121","doi-asserted-by":"crossref","first-page":"9","DOI":"10.21767\/AMJ.2017.3138","article-title":"Comparison of the effectiveness of femoral fixation techniques (Aperfix and Endobutton) in anterior cruciate ligament surgery: a clinical trial in men with complete anterior cruciate ligament rupture.","volume":"10","author":"Sharifzadeh","year":"2017","journal-title":"Australas Med J"},{"key":"R25-20250121","doi-asserted-by":"crossref","first-page":"938","DOI":"10.1055\/s-0040-1710363","article-title":"Comparison of clinical and radiological parameters with two different surgical methods for anterior cruciate ligament reconstruction.","volume":"33","author":"\u00c7ilo\u011flu","year":"2020","journal-title":"J Knee Surg"},{"key":"R26-20250121","doi-asserted-by":"crossref","first-page":"1059","DOI":"10.1007\/s00167-009-0952-4","article-title":"Comparison of plain radiography, computed tomography, and magnetic resonance imaging in the evaluation of bone tunnel widening after anterior cruciate ligament reconstruction.","volume":"18","author":"Marchant","year":"2010","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"R27-20250121","doi-asserted-by":"crossref","first-page":"946","DOI":"10.1016\/S0749-8063(04)00655-3","article-title":"A comparison of bone tunnel measurements made using computed tomography and digital plain radiography after anterior cruciate ligament reconstruction.","volume":"20","author":"Webster","year":"2004","journal-title":"Arthroscopy"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000041199","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,21]],"date-time":"2025-01-21T03:03:04Z","timestamp":1737428584000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000041199"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,17]]},"references-count":26,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000041199","relation":{},"ISSN":["1536-5964"],"issn-type":[{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,17]]}}}