{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T16:19:41Z","timestamp":1788970781240,"version":"build-2803163510"},"reference-count":30,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","license":[{"start":{"date-parts":[[2025,2,7]],"date-time":"2025-02-07T00:00:00Z","timestamp":1738886400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Right Pearl Limited","award":["TR1914524"],"award-info":[{"award-number":["TR1914524"]}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,2,7]]},"abstract":"<jats:p>The manual method of semen analysis is vital in andrology laboratories. To solve the labor-intensive, time-consuming, and subjective problem, computer-assisted sperm analysis (CASA) systems have been developed. However, it is unclear whether the consistency of semen analysis results especially in male infertility diagnoses can be achieved. A total of 326 individuals were recruited from January 14, 2020, to October 22, 2020. The manual method was used as the gold standard. Pairwise comparisons were conducted between CASAs (Hamilton-Thorne CEROS II Clinical, LensHooke X1 Pro, and SQA-V Gold Sperm Quality Analyzer) and manual method. LensHooke had the best performance in concentration, while the others showed moderate performances (intraclass correlation coefficient [ICC]: CEROS-0.723, LensHooke-0.842, SQA-V-0.631). CEROS II had moderate performances in motility, and the others only had poor agreements (ICC: CEROS-0.634, LensHooke-0.417, SQA-V-0.451). Morphology analyses were not consistent with manual results (ICC: LensHooke-0.160, SQA-V-0.261). In Bland\u2013Altman plots, CEROS II (<jats:italic toggle=\"yes\">P<\/jats:italic> = .379) and SQA-V Gold (<jats:italic toggle=\"yes\">P<\/jats:italic> = .218) showed consistent measurements in concentrations and total sperm count with the manual method, while the others were inconsistent. LensHooke X1 Pro (\u03ba=0.701) and CEROS II (\u03ba = 0.664) showed substantial performances in oligozoospermia, and SQA-V Gold had moderate agreements (\u03ba = 0.588). In asthenozoospermia, LensHooke X1 Pro had moderate performances (\u03ba = 0.405) and CEROS II had fair agreement (\u03ba = 0.249), while low agreement using SQA-V Gold (\u03ba = 0.157). In teratozoospermia, LensHooke X1 Pro (\u03ba = 0.177) and SQA-V Gold (\u03ba = 0.008) could not have consistent results either. When choosing treatment based on morphology, the ratio of intracytoplasmic sperm injection (ICSI) approximates 0.5 in our unit. However, the ratios were around 0.31 and 0.15 using LensHooke X1 Pro and SQA-V Gold, indicating the reduction of ICSI work in routine treatment. CASA results were not consistent with manual results, and the deviations might result in skewed in vitro fertilization\/ICSI allocation in subsequent treatment. Interestingly, tested CASA systems tend to skew to conventional in vitro fertilization instead of ICSI. Although CASA technologies have been improving recently, the manual method cannot be replaced by the tested CASA systems at present and the results should be treated with caution. CASA algorithms should be improved, especially in morphology. Future strict studies should be designed to evaluate the CASA systems with both internal and external validations.<\/jats:p>","DOI":"10.1097\/md.0000000000041501","type":"journal-article","created":{"date-parts":[[2025,2,10]],"date-time":"2025-02-10T20:01:29Z","timestamp":1739217689000},"page":"e41501","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["ICSI\/IVF treatments allocation using CASAs compared to manual semen analyses"],"prefix":"10.1097","volume":"104","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1115-1480","authenticated-orcid":false,"given":"Murong","family":"Xu","sequence":"first","affiliation":[{"name":"Assisted Reproductive Technology Unit, Department of Obstetrics and Gynaecology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China"},{"name":"School of Biomedical Sciences, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mingpeng","family":"Zhao","sequence":"additional","affiliation":[{"name":"Assisted Reproductive Technology Unit, Department of Obstetrics and Gynaecology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China"},{"name":"Heal Fertility Limited, Hong Kong, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huixia","family":"Yang","sequence":"additional","affiliation":[{"name":"Assisted Reproductive Technology Unit, Department of Obstetrics and Gynaecology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Minqi","family":"Liu","sequence":"additional","affiliation":[{"name":"Assisted Reproductive Technology Unit, Department of Obstetrics and Gynaecology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carol Pui Shan","family":"Chan","sequence":"additional","affiliation":[{"name":"Assisted Reproductive Technology Unit, Department of Obstetrics and Gynaecology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ka Kei","family":"Fung","sequence":"additional","affiliation":[{"name":"Assisted Reproductive Technology Unit, Department of Obstetrics and Gynaecology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacqueline Pui Wah","family":"Chung","sequence":"additional","affiliation":[{"name":"Assisted Reproductive Technology Unit, Department of Obstetrics and Gynaecology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ellis Kin Lam","family":"Fok","sequence":"additional","affiliation":[{"name":"School of Biomedical Sciences, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David Yiu Leung","family":"Chan","sequence":"additional","affiliation":[{"name":"Assisted Reproductive Technology Unit, Department of Obstetrics and Gynaecology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250210","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12958-015-0032-1","article-title":"A unique view on male infertility around the globe.","volume":"13","author":"Agarwal","year":"2015","journal-title":"Reprod Biol Endocrinol"},{"key":"R2-20250210","doi-asserted-by":"crossref","first-page":"e1001356","DOI":"10.1371\/journal.pmed.1001356","article-title":"National, regional, and global trends in infertility prevalence since 1990: a systematic analysis of 277 health surveys.","volume":"9","author":"Mascarenhas","year":"2012","journal-title":"PLoS Med"},{"key":"R3-20250210","doi-asserted-by":"crossref","first-page":"191","DOI":"10.4103\/0974-1208.170370","article-title":"Trends of male factor infertility, an important cause of infertility: a review of literature.","volume":"8","author":"Kumar","year":"2015","journal-title":"J Hum Reprod Sci"},{"key":"R4-20250210","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1093\/humrep\/16.2.215","article-title":"Quality of infertility care in poor-resource areas and the introduction of new reproductive technologies.","volume":"16","author":"Van Balen","year":"2001","journal-title":"Hum Reprod"},{"key":"R5-20250210","doi-asserted-by":"crossref","first-page":"e13149","DOI":"10.1111\/and.13149","article-title":"Automated semen analysis by SQA vision\u00ae versus the manual approach: a prospective double-blind study.","volume":"51","author":"Engel","year":"2019","journal-title":"Andrologia"},{"key":"R6-20250210","doi-asserted-by":"crossref","first-page":"e13614","DOI":"10.1111\/and.13614","article-title":"Diagnostic value of routine semen analysis in clinical andrology.","volume":"53","author":"Baskaran","year":"2021","journal-title":"Andrologia"},{"key":"R8-20250210","doi-asserted-by":"crossref","first-page":"763","DOI":"10.1111\/andr.12209","article-title":"Uncertainty of measurement and clinical value of semen analysis: has standardisation through professional guidelines helped or hindered progress?","volume":"4","author":"Tomlinson","year":"2016","journal-title":"Andrology"},{"key":"R9-20250210","doi-asserted-by":"crossref","first-page":"1084","DOI":"10.1111\/andr.12230","article-title":"Fifteen years of Belgian experience with external quality assessment of semen analysis.","volume":"4","author":"Punjabi","year":"2016","journal-title":"Andrology"},{"key":"R10-20250210","doi-asserted-by":"crossref","first-page":"2615","DOI":"10.1016\/j.fertnstert.2010.04.048","article-title":"Semenology training programs: 8 years\u2019 experience.","volume":"94","author":"Franken","year":"2010","journal-title":"Fertil Steril"},{"key":"R11-20250210","doi-asserted-by":"crossref","first-page":"52","DOI":"10.5534\/wjmh.210022","article-title":"Standardized laboratory procedures, quality control and quality assurance are key requirements for accurate semen analysis in the evaluation of infertile male.","volume":"40","author":"Agarwal","year":"2022","journal-title":"World J Mens Health"},{"key":"R12-20250210","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1093\/humrep\/13.1.142","article-title":"Guidelines on the application of CASA technology in the analysis of spermatozoa.","volume":"13","year":"1998","journal-title":"Hum Reprod"},{"key":"R13-20250210","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1016\/j.theriogenology.2013.09.004","article-title":"Computer-assisted sperm analysis (CASA): capabilities and potential developments.","volume":"81","author":"Amann","year":"2014","journal-title":"Theriogenology"},{"key":"R14-20250210","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1007\/978-1-60761-193-6_2","article-title":"Interpretation of basic semen analysis and advanced semen testing.","author":"Agarwal","year":"2011","journal-title":"Male Infertility Probl Solut"},{"key":"R15-20250210","doi-asserted-by":"crossref","first-page":"e13417","DOI":"10.1111\/and.13417","article-title":"Computer-aided sperm analysis, the new key player in routine sperm assessment.","volume":"51","author":"Schubert","year":"2019","journal-title":"Andrologia"},{"key":"R16-20250210","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1016\/j.theriogenology.2011.02.021","article-title":"Standardization of computer-assisted semen analysis using an e-learning application.","volume":"76","author":"Ehlers","year":"2011","journal-title":"Theriogenology"},{"key":"R17-20250210","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1093\/oxfordjournals.humrep.a138527","article-title":"Computer-assisted measurement of hyperactivation in human spermatozoa: differences between European and American versions of the Hamilton-Thorn motility analyser.","volume":"9","author":"Zhu","year":"1994","journal-title":"Hum Reprod"},{"key":"R18-20250210","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1002\/j.1939-4640.1993.tb00387.x","article-title":"Performance and comparison of CASA systems equipped with different phase-contrast optics.","volume":"14","author":"Yeung","year":"1993","journal-title":"J Androl"},{"key":"R19-20250210","first-page":"281","article-title":"Evaluation and assessment of semen for IVF\/ICSI.","volume":"4","author":"Liu","year":"2002","journal-title":"Asian J Androl"},{"key":"R20-20250210","doi-asserted-by":"crossref","first-page":"3069","DOI":"10.21037\/tau-21-276","article-title":"The validity and reliability of computer-aided semen analyzers in performing semen analysis: a systematic review.","volume":"10","author":"Finelli","year":"2021","journal-title":"Transl Androl Urol"},{"key":"R21-20250210","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1007\/s10815-013-0139-2","article-title":"Double-blind prospective study comparing two automated sperm analyzers versus manual semen assessment.","volume":"31","author":"Lammers","year":"2014","journal-title":"J Assist Reprod Genet"},{"key":"R22-20250210","doi-asserted-by":"crossref","first-page":"56","DOI":"10.5603\/GP.a2017.0012","article-title":"Manual vs. computer-assisted sperm analysis: can CASA replace manual assessment of human semen in clinical practice?","volume":"88","author":"Talarczyk-Desole","year":"2017","journal-title":"Ginekol Pol"},{"key":"R23-20250210","article-title":"WHO laboratory manual for the examination and processing of human semen.","year":"2010"},{"key":"R24-20250210","doi-asserted-by":"crossref","first-page":"3","DOI":"10.2466\/pr0.1966.19.1.3","article-title":"The intraclass correlation coefficient as a measure of reliability.","volume":"19","author":"Bartko","year":"1966","journal-title":"Psychol Rep"},{"key":"R25-20250210","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research.","volume":"15","author":"Koo","year":"2016","journal-title":"J Chiropr Med"},{"key":"R26-20250210","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1080\/00220670209598786","article-title":"An introduction to logistic regression analysis and reporting.","volume":"96","author":"Peng","year":"2002","journal-title":"J Educ Res"},{"key":"R28-20250210","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.tjem.2018.09.001","article-title":"Bland-Altman analysis: a paradigm to understand correlation and agreement.","volume":"18","author":"Do\u011fan","year":"2018","journal-title":"Turk J Emerg Med"},{"key":"R30-20250210","doi-asserted-by":"crossref","first-page":"276","DOI":"10.11613\/BM.2012.031","article-title":"Interrater reliability: the kappa statistic.","volume":"22","author":"McHugh","year":"2012","journal-title":"Biochem Med (Zagreb)"},{"key":"R31-20250210","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1214\/ss\/1032280214","article-title":"Bootstrap confidence intervals.","volume":"11","author":"DiCiccio","year":"1996","journal-title":"Stat Sci"},{"key":"R32-20250210","doi-asserted-by":"crossref","first-page":"496","DOI":"10.5534\/wjmh.200185","article-title":"Validation of LensHooke\u00ae X1 PRO and computer-assisted semen analyzer compared with laboratory-based manual semen analysis.","volume":"39","author":"Agarwal","year":"2021","journal-title":"World J Mens Health"},{"key":"R33-20250210","doi-asserted-by":"crossref","first-page":"e13440","DOI":"10.1111\/and.13440","article-title":"Automation of human semen analysis using a novel artificial intelligence optical microscopic technology.","volume":"51","author":"Agarwal","year":"2019","journal-title":"Andrologia"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000041501","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,10]],"date-time":"2025-02-10T20:01:39Z","timestamp":1739217699000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000041501"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,7]]},"references-count":30,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000041501","relation":{},"ISSN":["1536-5964"],"issn-type":[{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,7]]}}}