{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,15]],"date-time":"2025-08-15T00:28:56Z","timestamp":1755217736144,"version":"3.43.0"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","license":[{"start":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T00:00:00Z","timestamp":1740096000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,2,21]]},"abstract":"<jats:p>The study aimed to evaluate the reliability of the intraoperative extended tangential view (ETV) in assessing the reduction and fixation of the dorsoulnar fragment (DUF) during the treatment of comminuted distal radius fractures (DRFs) with volar plates. A retrospective review included 26 patients who underwent open reduction and volar locking plate internal fixation for AO C3-type DRFs with DUF between March 2023 and January 2024. Each patient received intraoperative ETV fluoroscopy and immediate postoperative wrist CT scans. DUF reduction quality was classified simply as excellent (anatomical reduction), good (&lt;2\u2005mm residual displacement), or poor (&gt; 2\u2005mm displacement). Both reduction quality and screw position relative to DUF were independently evaluated through fluoroscopy and CT. The study found consistent results across both methods: 23 reductions were excellent, 2 were good, and 1 was poor. The screw\u2019s mean distance to the distal radioulnar joint was 6.19\u2005\u00b1\u20052.76\u2005mm on ETV compared to 4.21\u2005\u00b1\u20052.05\u2005mm on CT, with a Pearson correlation of 0.925 (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2005&lt;\u2005.05). The screw tip\u2019s distance to the dorsal cortex measured 3.69\u2005\u00b1\u20051.08\u2005mm on ETV versus and 2.72\u2005\u00b1\u20051.01\u2005mm on CT, with a correlation of 0.937 (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2005&lt;\u2005.05). When compared to the postoperative CT evaluation, which was deemed the gold standard, the intraoperative ETV measurements displayed excellent accuracy and substantial relevance to the CT findings. The study suggests that the intraoperative ETV is a valuable tool for assessing the reduction and fixation quality of the DUF in comminuted DRFs. Level IV, retrospective case series.<\/jats:p>","DOI":"10.1097\/md.0000000000041663","type":"journal-article","created":{"date-parts":[[2025,2,24]],"date-time":"2025-02-24T15:03:13Z","timestamp":1740409393000},"page":"e41663","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Intraoperative assessment of the dorsoulnar fragment reduction and fixation with extended tangential view: A study of diagnostic accuracy"],"prefix":"10.1097","volume":"104","author":[{"given":"Yu","family":"Zhang","sequence":"first","affiliation":[{"name":"Department of Orthopaedics, The First Hospital Affiliated to Nanjing Medical University & Jiangsu Provincial People\u2019s Hospital, Nanjing, Jiangsu, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7864-4231","authenticated-orcid":false,"given":"Siyuan","family":"Qing","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Nanjing Pukou Hospital of Traditional Chinese Medicine, Nanjing, Jiangsu, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guoyong","family":"Yin","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, The First Hospital Affiliated to Nanjing Medical University & Jiangsu Provincial People\u2019s Hospital, Nanjing, Jiangsu, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chun","family":"Lu","sequence":"additional","affiliation":[{"name":"School of Basic Medical Sciences of Nanjing Medical University, Nanjing, Jiangsu, China."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250805","doi-asserted-by":"crossref","first-page":"1900","DOI":"10.2106\/00004623-200409000-00007","article-title":"Loss of fixation of the volar lunate facet fragment in fractures of the distal part of the radius.","volume":"86","author":"Harness","year":"2004","journal-title":"J Bone Joint Surg Am"},{"key":"R2-20250805","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1016\/S0030-5898(20)31312-2","article-title":"Articular fractures of the distal radius.","volume":"15","author":"Melone","year":"1984","journal-title":"Orthop Clin North Am"},{"key":"R3-20250805","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1055\/s-0036-1579549","article-title":"Stabilization of volar ulnar rim fractures of the distal radius: current techniques and review of the literature.","volume":"5","author":"O\u2019Shaughnessy","year":"2016","journal-title":"J Wrist Surg"},{"key":"R4-20250805","doi-asserted-by":"crossref","first-page":"1315","DOI":"10.1007\/s00402-015-2290-y","article-title":"The effects of the Frag-Loc(\u00ae) compression screw on distal radius fracture with a displaced dorsoulnar fragment.","volume":"135","author":"Lee","year":"2015","journal-title":"Arch Orthop Trauma Surg"},{"key":"R5-20250805","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1016\/j.injury.2011.03.049","article-title":"The effects of a displaced dorsal rim fracture on outcomes after volar plate fixation of a distal radius fracture.","volume":"43","author":"Kim","year":"2012","journal-title":"Injury"},{"key":"R6-20250805","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1055\/s-0035-1571184","article-title":"The effect of displaced dorsal rim fragment in a distal radius fracture.","volume":"5","author":"Kim","year":"2016","journal-title":"J Wrist Surg"},{"key":"R7-20250805","first-page":"27","article-title":"Distal radius fractures: strategic alternatives to volar plate fixation.","volume":"63","author":"Dy","year":"2014","journal-title":"Instr Course Lect"},{"key":"R8-20250805","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1142\/S0218810414970016","article-title":"Fixation of an ulnodorsal fragment when treating an intra-articular fracture in the distal radius.","volume":"19","author":"Ikeda","year":"2014","journal-title":"Hand Surg"},{"key":"R9-20250805","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1007\/s00064-012-0223-2","article-title":"Die dorsale Kapseldoppelung zur Therapie der dorsalen Instabilit\u00e4t des distalen Radioulnargelenks [Dorsal capsular imbrication for dorsal instability of the distal radioulnar joint].","volume":"25","author":"Unglaub","year":"2013","journal-title":"Oper Orthop Traumatol"},{"key":"R10-20250805","doi-asserted-by":"crossref","first-page":"2004","DOI":"10.1016\/j.injury.2019.08.003","article-title":"Size and stabilization of the dorsoulnar fragment in AO C3-type distal radius fractures.","volume":"50","author":"Miyashima","year":"2019","journal-title":"Injury"},{"key":"R11-20250805","doi-asserted-by":"crossref","first-page":"1868","DOI":"10.2106\/JBJS.H.01297","article-title":"Trends in the United States in the treatment of distal radial fractures in the elderly.","volume":"91","author":"Chung","year":"2009","journal-title":"J Bone Joint Surg Am"},{"key":"R12-20250805","doi-asserted-by":"crossref","first-page":"2687","DOI":"10.2106\/00004623-200612000-00016","article-title":"Treatment of unstable distal radial fractures with the volar locking plating system.","volume":"88","author":"Chung","year":"2006","journal-title":"J Bone Joint Surg Am"},{"key":"R13-20250805","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1097\/BTO.0000000000000318","article-title":"Radiographic evaluation of the distal radioulnar joint: technique to detect sigmoid notch intra-articular screw breach in distal radius fractures.","volume":"35","author":"Klein","year":"2020","journal-title":"Tech Orthop"},{"key":"R14-20250805","doi-asserted-by":"crossref","first-page":"1121","DOI":"10.1007\/s00402-010-1211-3","article-title":"Arthritis predicting factors in distal intraarticular radius fractures.","volume":"131","author":"Lutz","year":"2011","journal-title":"Arch Orthop Trauma Surg"},{"key":"R15-20250805","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1054\/jhsb.2000.0388","article-title":"Theoretical stress analysis in wrist joint\u2014neutral position and functional position.","volume":"25","author":"Genda","year":"2000","journal-title":"J Hand Surg Br"},{"key":"R16-20250805","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1016\/0363-5023(92)90417-N","article-title":"Force distribution across wrist joint: application of pressure-sensitive conductive rubber.","volume":"17","author":"Hara","year":"1992","journal-title":"J Hand Surg Am"},{"key":"R17-20250805","doi-asserted-by":"crossref","first-page":"958","DOI":"10.1016\/j.jhsa.2008.04.018","article-title":"Volar approach to distal radius fractures.","volume":"33","author":"Protopsaltis","year":"2008","journal-title":"J Hand Surg Am"},{"key":"R18-20250805","doi-asserted-by":"crossref","first-page":"e978","DOI":"10.3928\/01477447-20141023-54","article-title":"Hardware-related complications after dorsal plating for displaced distal radius fractures.","volume":"37","author":"Matzon","year":"2014","journal-title":"Orthopedics"},{"key":"R19-20250805","doi-asserted-by":"crossref","first-page":"1684","DOI":"10.1016\/j.injury.2019.07.018","article-title":"How effective is skyline view for avoiding dorsal cortex penetration in volar plate fixation of intra-articular and dorsal cortex comminuted distal radius fractures.","volume":"50","author":"\u00d6zbek","year":"2019","journal-title":"Injury"},{"key":"R20-20250805","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1142\/S2424835518500030","article-title":"Use of computed tomography in determining the occurrence of dorsal and intra-articular screw penetration in volar locking plate osteosynthesis of distal radius fracture.","volume":"23","author":"Diong","year":"2018","journal-title":"J Hand Surg Asian Pac Vol"},{"key":"R21-20250805","first-page":"17","article-title":"Anatomical studies on the geometry and stability of the distal radio ulnar joint.","volume":"19","author":"af Ekenstam","year":"1985","journal-title":"Scand J Plast Reconstr Surg"},{"key":"R22-20250805","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1016\/j.jhsa.2011.12.009","article-title":"Intraoperative imaging of the distal radioulnar joint using a modified skyline view.","volume":"37","author":"Klammer","year":"2012","journal-title":"J Hand Surg Am"},{"key":"R23-20250805","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1007\/s11552-014-9607-0","article-title":"Volar locking plate fixation of distal radius fractures: use of an intra-operative \u2018carpal shoot through\u2019 view to identify dorsal compartment and distal radioulnar joint screw penetration.","volume":"9","author":"Marsland","year":"2014","journal-title":"Hand (N Y)"},{"key":"R24-20250805","doi-asserted-by":"crossref","first-page":"1038.e1","DOI":"10.1016\/j.jhsa.2018.03.016","article-title":"The sigmoid notch view for distal radius fractures.","volume":"43","author":"Kamal","year":"2018","journal-title":"J Hand Surg Am"},{"key":"R25-20250805","doi-asserted-by":"crossref","first-page":"1486","DOI":"10.1016\/j.jhsa.2008.05.017","article-title":"Assessment of distal radioulnar joint instability after distal radius fracture: comparison of computed tomography and clinical examination results.","volume":"33","author":"Kim","year":"2008","journal-title":"J Hand Surg Am"},{"key":"R26-20250805","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1053\/jhsu.2001.22930","article-title":"Evaluation of the sigmoid notch with computed tomography following intra-articular distal radius fracture.","volume":"26","author":"Rozental","year":"2001","journal-title":"J Hand Surg Am"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000041663","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,5]],"date-time":"2025-08-05T17:23:13Z","timestamp":1754414593000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000041663"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,21]]},"references-count":26,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000041663","relation":{},"ISSN":["1536-5964"],"issn-type":[{"type":"electronic","value":"1536-5964"}],"subject":[],"published":{"date-parts":[[2025,2,21]]}}}