{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T17:38:35Z","timestamp":1757612315142,"version":"3.44.0"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"17","license":[{"start":{"date-parts":[[2025,4,25]],"date-time":"2025-04-25T00:00:00Z","timestamp":1745539200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,4,25]]},"abstract":"<jats:sec>\n            <jats:title>Rationale:<\/jats:title>\n            <jats:p>Foreign body (FB) ingestion is common, particularly among children. While most FBs pass through the gastrointestinal tract without complications, some cases can lead to morbidity or even mortality. Management strategies depend on the size, sharpness, toxicity, and location of the FB. Plain radiographs are essential for diagnosis, treatment planning, and follow-up, especially for radiopaque FBs. Ingestion of dental-related FBs is rare, with reported cases involving orthodontic wires, braces, retainers, and other dental materials. Composite resin-wire splints are commonly used in orthodontics to manage dental traumatic injuries. We present a case of a patient who ingested a composite resin-wire splint, initially misclassified as a sharp FB, leading to unnecessary aggressive treatment.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patient concerns:<\/jats:title>\n            <jats:p>A 2-year-old girl presented to the emergency department after accidentally ingesting a FB of dental origin. She had a recent traumatic dental injury and displayed no symptoms of ingestion. Initial radiographs revealed a dental wire in the stomach.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Diagnoses:<\/jats:title>\n            <jats:p>Ingestion of orthodontic splint (composite resin-wire splint).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Interventions:<\/jats:title>\n            <jats:p>Considering the pointed tip of the wire, the emergency department physician transferred her to the endoscopy specialist for endoscopic removal. However, given the expected passage into the small bowel after a proper fasting period for endoscopy, close observation with follow-up radiographs was chosen amid parental anxiety.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Outcomes:<\/jats:title>\n            <jats:p>Follow-up imaging showed FB migration to the ascending colon without perforation. Stool inspection revealed the dental wire and 4 composite resins, with the sharp tips covered by the resin, classifying it as a blunt FB. A retrospective review of radiographs revealed faint oval-shaped, mid-level radiopacities at each end of the wire covering the sharp\/pointed tips.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Lessons:<\/jats:title>\n            <jats:p>In evaluating orthodontic splints as FBs, identifying faint composite resin on radiographs is crucial for planning milder treatment and alleviating parental anxiety.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/md.0000000000041843","type":"journal-article","created":{"date-parts":[[2025,4,28]],"date-time":"2025-04-28T23:01:04Z","timestamp":1745881264000},"page":"e41843","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["A case of orthodontic splint ingestion misclassified as a sharp\/pointed foreign body in a child: A case report"],"prefix":"10.1097","volume":"104","author":[{"ORCID":"https:\/\/orcid.org\/0009-0006-8395-8696","authenticated-orcid":false,"given":"Hyun Kyung","family":"Lee","sequence":"first","affiliation":[{"name":"Department of Radiology, Jeonbuk National University Medical School and Hospital, Jeonju, Republic of Korea"},{"name":"Research Institute of Clinical Medicine of Jeonbuk National University-Biomedical Research Institute of Jeonbuk National University Hospital, Jeonju, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5139-552X","authenticated-orcid":false,"given":"Jung Hee","family":"Byon","sequence":"additional","affiliation":[{"name":"Department of Radiology, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, Republic of Korea."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eun Hae","family":"Park","sequence":"additional","affiliation":[{"name":"Department of Radiology, Jeonbuk National University Medical School and Hospital, Jeonju, Republic of Korea"},{"name":"Research Institute of Clinical Medicine of Jeonbuk National University-Biomedical Research Institute of Jeonbuk National University Hospital, Jeonju, Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"issue":"1 Suppl","key":"R1-20250904","first-page":"S75","article-title":"Endoscopic management of gastrointestinal foreign bodies in children.","volume":"66","author":"Seo","year":"1999","journal-title":"Indian J Pediatr"},{"key":"R2-20250904","doi-asserted-by":"crossref","first-page":"1","DOI":"10.5223\/pghn.2023.26.1.1","article-title":"Management of gastrointestinal foreign bodies with brief review of the guidelines.","volume":"26","author":"Demiroren","year":"2023","journal-title":"Pediatr Gastroenterol Hepatol Nutr"},{"key":"R3-20250904","doi-asserted-by":"crossref","first-page":"129","DOI":"10.5946\/ce.2018.039","article-title":"Foreign body ingestion in children.","volume":"51","author":"Lee","year":"2018","journal-title":"Clin Endosc"},{"key":"R4-20250904","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1093\/ortho\/27.4.295","article-title":"Hazards of orthodontics appliances and the oropharynx.","volume":"27","author":"Dibiase","year":"2000","journal-title":"J Orthod"},{"key":"R5-20250904","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1016\/S0300-9785(86)80116-8","article-title":"Foreign bodies of dental origin in the air and food passages.","volume":"15","author":"Tamura","year":"1986","journal-title":"Int J Oral Maxillofac Surg"},{"key":"R6-20250904","doi-asserted-by":"crossref","first-page":"24","DOI":"10.3390\/dj4030024","article-title":"An ingested orthodontic wire fragment: a case report.","volume":"4","author":"Puryer","year":"2016","journal-title":"Dent J (Basel)"},{"key":"R7-20250904","doi-asserted-by":"crossref","first-page":"37","DOI":"10.2214\/AJR.13.12185","article-title":"Clinical guidelines for imaging and reporting ingested foreign bodies.","volume":"203","author":"Guelfguat","year":"2014","journal-title":"AJR Am J Roentgenol"},{"key":"R8-20250904","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1259\/dmfr.24.2.9515387","article-title":"The location and tracking of swallowed dental appliances: the role of radiology.","volume":"24","author":"Absi","year":"1995","journal-title":"Dentomaxillofac Radiol"},{"key":"R9-20250904","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1016\/S0002-9610(41)90652-9","article-title":"Perforations of the intestine by ingested foreign bodies: report of two cases and review of the literature.","volume":"53","author":"Macmanus","year":"1941","journal-title":"Am J Surg"},{"key":"R10-20250904","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1002\/bjs.18003915619","article-title":"Perforation of the intestine of intestine by swallowed foreign bodies, with a report of two cases of perforation by rabbit bones.","volume":"39","author":"Ward-McQuaid","year":"1952","journal-title":"Br J Surg"},{"key":"R11-20250904","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1016\/j.gie.2008.05.072","article-title":"Foreign-body ingestion: characteristics and outcomes in a lower socioeconomic population with predominantly intentional ingestion.","volume":"69","author":"Palta","year":"2009","journal-title":"Gastrointest Endosc"},{"key":"R12-20250904","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1542\/peds.91.1.121","article-title":"Foreign body ingestions in children: risk of complication varies with site of initial health care contact. Pediatric Practice Research Group.","volume":"91","author":"Paul","year":"1993","journal-title":"Pediatrics"},{"key":"R13-20250904","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1053\/j.sult.2014.10.008","article-title":"Role of plain radiography in the assessment of ingested foreign bodies in the pediatric patients.","volume":"36","author":"Pinto","year":"2015","journal-title":"Semin Ultrasound CT MR"},{"key":"R14-20250904","doi-asserted-by":"crossref","first-page":"1085","DOI":"10.1016\/j.gie.2010.11.010","article-title":"Management of ingested foreign bodies and food impactions.","volume":"73","author":"Ikenberry","year":"2011","journal-title":"Gastrointest Endosc"},{"key":"R15-20250904","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1111\/adj.12398","article-title":"Splinting of teeth following trauma: a review and a new splinting recommendation.","volume":"61","author":"Kahler","year":"2016","journal-title":"Aust Dent J"},{"key":"R16-20250904","doi-asserted-by":"crossref","first-page":"5789","DOI":"10.1016\/j.biomaterials.2004.01.026","article-title":"Effect of resin hydrophilicity and water storage on resin strength.","volume":"25","author":"Yiu","year":"2004","journal-title":"Biomaterials"},{"key":"R17-20250904","first-page":"20","article-title":"Radiopacity of compomers, flowable and conventional resin composites for posterior restorations.","volume":"24","author":"Bouschlicher","year":"1999","journal-title":"Oper Dent"},{"key":"R18-20250904","doi-asserted-by":"crossref","first-page":"17","DOI":"10.4103\/0972-0707.209071","article-title":"Comparison of radiopacity of different composite resins.","volume":"20","author":"Gul","year":"2017","journal-title":"J Conserv Dent"},{"key":"R20-20250904","doi-asserted-by":"crossref","first-page":"199","DOI":"10.5624\/isd.2014.44.3.199","article-title":"Effect of changing the kilovoltage peak on radiographic caries assessment in digital and conventional radiography.","volume":"44","author":"Zayet","year":"2014","journal-title":"Imaging Sci Dent"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000041843","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,4]],"date-time":"2025-09-04T12:04:32Z","timestamp":1756987472000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000041843"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,25]]},"references-count":19,"journal-issue":{"issue":"17","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000041843","relation":{},"ISSN":["1536-5964"],"issn-type":[{"type":"electronic","value":"1536-5964"}],"subject":[],"published":{"date-parts":[[2025,4,25]]}}}