{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,8]],"date-time":"2026-05-08T14:30:44Z","timestamp":1778250644642,"version":"3.51.4"},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"11","license":[{"start":{"date-parts":[[2025,3,14]],"date-time":"2025-03-14T00:00:00Z","timestamp":1741910400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,3,14]]},"abstract":"<jats:sec>\n                    <jats:title>Rationale:<\/jats:title>\n                    <jats:p>This case series explores dynamic navigation systems (DNS) in transmandibular nerve canal implantation for patients with limited jaw space due to the proximity of the inferior alveolar nerve (IAN). The aim is to demonstrate how DNS improves implant placement precision and safety in cases where traditional methods face challenges.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Patient concerns:<\/jats:title>\n                    <jats:p>The patients had limited bone height and proximity to the IAN, making traditional implant techniques challenging. Concerns included the risk of nerve damage and difficulties in achieving optimal implant placement due to anatomical constraints.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Diagnoses:<\/jats:title>\n                    <jats:p>Both patients had severe bone resorption and insufficient bone height in the posterior mandible, with concerns about IAN positioning. The first patient had grade III mobility in tooth #46 with a periapical infection, while the second had bilateral posterior mandibular pain and grade III mobility in tooth #47.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Interventions:<\/jats:title>\n                    <jats:p>Implants were placed using DNS, allowing precise planning and real-time guidance during surgery. Based on cone beam computed tomography, preoperative planning assessed bone height and IAN proximity. DNS ensured accurate implant placement, avoiding nerve interference, while bone grafts and growth factors were applied for healing.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Outcomes:<\/jats:title>\n                    <jats:p>Both cases showed successful implant placement without complications like nerve damage or implant misplacement. Follow-up cone beam computed tomography scans confirmed well-positioned implants, with minimal bone resorption in the first case over 2 years and stable conditions in the second case after 6 months.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Lessons:<\/jats:title>\n                    <jats:p>This series highlights DNS\u2019s effectiveness in improving implant accuracy and reducing nerve injury risks, suggesting its value in complex dental implant surgeries.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/md.0000000000041922","type":"journal-article","created":{"date-parts":[[2025,3,18]],"date-time":"2025-03-18T15:03:27Z","timestamp":1742310207000},"page":"e41922","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["From freehand to precision: Dynamic navigation systems in transmandibular nerve canal implantation: A case series"],"prefix":"10.1097","volume":"104","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-0867-8498","authenticated-orcid":false,"given":"Shiwei","family":"Che","sequence":"first","affiliation":[{"name":"School of Dental Sciences, Health Campus, Universiti Sains Malaysia, Kelantan, Malaysia"},{"name":"Dr. Che Dental Clinic, Luzhou City, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5018-6048","authenticated-orcid":false,"given":"Noor Huda","family":"Ismail","sequence":"additional","affiliation":[{"name":"Prosthodontics Unit, School of Dental Sciences, Health Campus, Universiti Sains Malaysia, Kelantan, Malaysia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wuxiang","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Trauma Surgery, The First People\u2019s Hospital of Zhaotong, Zhaotong City, Yunnan Province, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Raja Azman","family":"Awang","sequence":"additional","affiliation":[{"name":"Periodontics Unit, School of Dental Sciences, Health Campus, Universiti Sains Malaysia, Kelantan, Malaysia."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"issue":"Suppl 16","key":"R1-20260108","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1111\/clr.13342","article-title":"Group 1 ITI consensus report: the influence of implant length and design and medications on clinical and patient-reported outcomes.","volume":"29","author":"Jung","year":"2018","journal-title":"Clin Oral Implants Res"},{"key":"R2-20260108","doi-asserted-by":"crossref","first-page":"406","DOI":"10.3390\/diagnostics10060406","article-title":"A CBCT based three-dimensional assessment of mandibular posterior region for evaluating the possibility of bypassing the inferior alveolar nerve while placing dental implants.","volume":"10","author":"Sghaireen","year":"2020","journal-title":"Diagnostics (Basel)"},{"key":"R3-20260108","doi-asserted-by":"crossref","first-page":"639","DOI":"10.11607\/prd.1895","article-title":"Bone dimensions in the posterior mandible: a retrospective radiographic study using cone beam computed tomography. Part 2\u2014analysis of edentulous sites.","volume":"34","author":"Braut","year":"2014","journal-title":"Int J Periodontics Restorative Dent"},{"key":"R4-20260108","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1097\/ID.0000000000000489","article-title":"Ridge dimensions of the edentulous mandible in posterior sextants: an observational study on cone beam computed tomography radiographs.","volume":"26","author":"Bressan","year":"2017","journal-title":"Implant Dent"},{"key":"R6-20260108","doi-asserted-by":"crossref","first-page":"16229","DOI":"10.1038\/s41598-020-73180-3","article-title":"CT-based dentulous mandibular alveolar ridge measurements as predictors of crown-to-implant ratio for short and extra short dental implants.","volume":"10","author":"Sivolella","year":"2020","journal-title":"Sci Rep"},{"key":"R7-20260108","doi-asserted-by":"crossref","first-page":"104567","DOI":"10.1016\/j.jdent.2023.104567","article-title":"Accuracy assessment of dynamic navigation during implant placement: a systematic review and meta-analysis of clinical studies in the last 10 years.","volume":"135","author":"Yu","year":"2023","journal-title":"J Dent"},{"key":"R8-20260108","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1111\/clr.13301","article-title":"Proceedings of the 6th ITI consensus conference.","volume":"29","author":"Wismeijer","year":"2018","journal-title":"Clin Oral Implants Res"},{"key":"R9-20260108","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1111\/cid.13103","article-title":"Short and ultra-short (<6-mm) locking-taper implants supporting single crowns in posterior areas (part II): a 5-year retrospective study on periodontally healthy patients and patients with a history of periodontitis.","volume":"24","author":"Lombardo","year":"2022","journal-title":"Clin Implant Dent Relat Res"},{"key":"R10-20260108","first-page":"130","article-title":"Radiological measurement and analysis of trans-inferior alveolar nerve implantation.","volume":"2","author":"Jinming","year":"2023","journal-title":"Stomatology"},{"key":"R11-20260108","doi-asserted-by":"crossref","first-page":"1622","DOI":"10.1016\/j.jcms.2017.07.007","article-title":"Intracanal temperature changes during bone preparations close to and penetrating the inferior alveolar canal: drills versus piezosurgery.","volume":"45","author":"Szalma","year":"2017","journal-title":"J Craniomaxillofac Surg"},{"key":"R12-20260108","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1016\/j.jdent.2013.12.014","article-title":"Risk assessment of inferior alveolar nerve injury for immediate implant placement in the posterior mandible: a virtual implant placement study.","volume":"42","author":"Lin","year":"2014","journal-title":"J Dent"},{"key":"R13-20260108","doi-asserted-by":"crossref","first-page":"1212","DOI":"10.1111\/clr.13386","article-title":"Long-term follow-up of single crowns supported by short, moderately rough implants\u2014a prospective 10-year cohort study.","volume":"29","author":"Rossi","year":"2018","journal-title":"Clin Oral Implants Res"},{"key":"R14-20260108","doi-asserted-by":"crossref","first-page":"77","DOI":"10.3390\/dj10050077","article-title":"Influence of implant tilting and length on the biomechanics of single-tooth restoration: a finite element analysis in atrophic mandible.","volume":"10","author":"Anitua","year":"2022","journal-title":"Dent J"},{"key":"R15-20260108","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1186\/s12903-024-03947-x","article-title":"Immediate implant placement in the posterior mandibular region was assisted by dynamic real-time navigation: a retrospective study.","volume":"24","author":"Geng","year":"2024","journal-title":"BMC Oral Health"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000041922","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T21:00:29Z","timestamp":1767906029000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000041922"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,14]]},"references-count":14,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000041922","relation":{},"ISSN":["1536-5964"],"issn-type":[{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,14]]}}}