{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T10:55:49Z","timestamp":1793876149112,"version":"4.7.0"},"reference-count":89,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"14","license":[{"start":{"date-parts":[[2025,4,4]],"date-time":"2025-04-04T00:00:00Z","timestamp":1743724800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,4,4]]},"abstract":"<jats:p>Congenital cataract is a lens opacification that disrupts normal visual development, requiring early surgical intervention to prevent amblyopia. In children, timely surgery, followed by optical correction and vision rehabilitation, is crucial for achieving binocular vision with foveal fixation. The recommended surgical timing is within 8 weeks for unilateral cases and by 4 months for bilateral cases to minimize long-term visual impairment. Despite advancements in intraocular lens (IOL) technology and ophthalmic microsurgery, accurate IOL power selection in pediatric patients remains a challenge due to axial length growth, biometric variability, and the reliance on formulas derived from adult models. These factors contribute to postoperative refractive errors, making proper formula selection essential in minimizing additional corrective interventions. Traditional third-generation formulas, such as the Sanders\u2013Retzlaff\u2013Kraff-T and Holladay 1, are commonly used in pediatric cases. However, recent studies suggest that Barrett Universal II offers greater accuracy in older children, owing to its advanced vergence-based algorithm and improved axial length prediction. Emerging formulas, including Hill-RBF 3.0 and Kane, show promise but require further validation in pediatric cohorts. Additionally, ocular growth dynamics must be accounted for when determining postoperative refractive targets. Younger children often require undercorrection to compensate for axial elongation, and biometric formulas must be chosen accordingly to optimize long-term outcomes. The lack of pediatric-specific formulas further complicates IOL selection, emphasizing the need for new models that integrate machine learning algorithms and growth prediction data.<\/jats:p>","DOI":"10.1097\/md.0000000000042072","type":"journal-article","created":{"date-parts":[[2025,4,16]],"date-time":"2025-04-16T12:00:47Z","timestamp":1744804847000},"page":"e42072","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":8,"title":["Intraocular lens power calculation in pediatric cataract surgery: A narrative review"],"prefix":"10.1097","volume":"104","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6753-2904","authenticated-orcid":false,"given":"Bogumi\u0142a","family":"W\u00f3jcik-Niklewska","sequence":"first","affiliation":[{"name":"Department of Pediatric Ophthalmology, Faculty of Medical Sciences in Katowice, Medical University of Silesia, Poland"},{"name":"Professor Kornel Gibi\u0144ski University Hospital Center, Medical University of Silesia, Katowice, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martyna","family":"Noco\u0144-Bratek","sequence":"additional","affiliation":[{"name":"Professor Kornel Gibi\u0144ski University Hospital Center, Medical University of Silesia, Katowice, Poland"},{"name":"Department of Ophtalmology, Faculty of Medical Sciences in Katowice, Medical University of Silesia, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-7715-8024","authenticated-orcid":false,"given":"Klaudia","family":"Szala","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Students\u2019 Scientific Society, Faculty of Medical Sciences in Katowice, Medical University of Silesia, Katowice, Poland."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250416","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1097\/j.jcrs.0000000000000015","article-title":"Comparison of visual acuity and complications between primary IOL implantation and aphakia in patients with congenital cataract younger than 2 years: a meta-analysis.","volume":"46","author":"Chen","year":"2020","journal-title":"J Cataract Refract Surg"},{"key":"R2-20250416","doi-asserted-by":"crossref","first-page":"28564","DOI":"10.1038\/srep28564","article-title":"Prevalence and epidemiological characteristics of congenital cataract: a systematic review and meta-analysis.","volume":"6","author":"Wu","year":"2016","journal-title":"Sci Rep"},{"key":"R3-20250416","first-page":"77","article-title":"Pediatric cataract: challenges and future directions.","volume":"9","author":"Medsinge","year":"2015","journal-title":"Clin Ophthalmol"},{"key":"R4-20250416","first-page":"1025","article-title":"Congenital cataract etiology.","volume":"85","author":"El Fkih","year":"2007","journal-title":"Tunis Med"},{"key":"R5-20250416","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1016\/S0896-1549(05)70250-9","article-title":"Eye manifestations of intrauterine infections.","volume":"14","author":"Mets","year":"2001","journal-title":"Ophthalmol Clin North Am"},{"key":"R6-20250416","doi-asserted-by":"crossref","first-page":"414","DOI":"10.3109\/08820538.2014.959192","article-title":"Complications of pediatric cataract surgery.","volume":"29","author":"Whitman","year":"2014","journal-title":"Semin Ophthalmol"},{"key":"R7-20250416","first-page":"24","article-title":"Association between preoperative ocular parameters and myopic shift in children undergoing primary intraocular lens implantation.","volume":"13","author":"Li","year":"2024","journal-title":"Transl Vis Sci Technol"},{"key":"R8-20250416","doi-asserted-by":"crossref","first-page":"83","DOI":"10.3928\/00904481-20110117-07","article-title":"Pediatric cataract.","volume":"40","author":"Mickler","year":"2011","journal-title":"Pediatr Ann"},{"key":"R9-20250416","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1001\/jamaophthalmol.2015.1329","article-title":"Glaucoma-related adverse events in the first 5 years after unilateral cataract removal in the infant aphakia treatment study.","volume":"133","author":"Freedman","year":"2015","journal-title":"JAMA Ophthalmol"},{"key":"R10-20250416","doi-asserted-by":"crossref","first-page":"670","DOI":"10.1016\/S0161-6420(91)32235-8","article-title":"Glaucoma after pediatric lensectomy\/vitrectomy.","volume":"98","author":"Simon","year":"1991","journal-title":"Ophthalmology"},{"key":"R11-20250416","doi-asserted-by":"crossref","first-page":"14","DOI":"10.3928\/0191-3913-19960101-05","article-title":"Prevalence of glaucoma after surgery for PHPV and infantile cataract.","volume":"33","author":"Johnson","year":"1996","journal-title":"J Pediatr Ophthalmol Strabismus"},{"key":"R12-20250416","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1034\/j.1600-0420.2000.078001065.x","article-title":"Glaucoma following congenital cataract surgery: an 18-year longitudinal follow-up.","volume":"78","author":"Magnusson","year":"2000","journal-title":"Acta Ophthalmol Scand"},{"key":"R13-20250416","doi-asserted-by":"crossref","first-page":"1791","DOI":"10.1167\/iovs.07-1156","article-title":"Risk of glaucoma after pediatric cataract surgery.","volume":"49","author":"Haargaard","year":"2008","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R14-20250416","doi-asserted-by":"crossref","first-page":"139","DOI":"10.3928\/0191-3913-19920501-04","article-title":"Endophthalmitis following pediatric intraocular surgery for congenital cataracts and congenital glaucoma.","volume":"29","author":"Wheeler","year":"1992","journal-title":"J Pediatr Ophthalmol Strabismus"},{"key":"R15-20250416","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.ajo.2008.02.014","article-title":"Risk factors for complications after congenital cataract surgery without intraocular lens implantation in the first 18 months of life.","volume":"146","author":"Kuhli-Hattenbach","year":"2008","journal-title":"Am J Ophthalmol"},{"key":"R16-20250416","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1016\/j.jaapos.2004.12.013","article-title":"Frequency and predictors of retinal detachment after pediatric cataract surgery without primary intraocular lens implantation.","volume":"9","author":"Rabiah","year":"2005","journal-title":"J AAPOS"},{"key":"R17-20250416","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1002\/micr.20460","article-title":"Primary posterior capsulorhexis with anterior vitrectomy in preventing posterior capsule opacification in pediatric cataract microsurgery.","volume":"28","author":"Luo","year":"2008","journal-title":"Microsurgery"},{"key":"R18-20250416","doi-asserted-by":"crossref","first-page":"1273","DOI":"10.1136\/bjo.2009.159871","article-title":"Iris claw lenses in aphakia.","volume":"93","author":"Gicquel","year":"2009","journal-title":"Br J Ophthalmol"},{"key":"R20-20250416","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1111\/opo.12925","article-title":"Binocular visual function and fixational control in patients with macular disease: a review.","volume":"42","author":"Sverdlichenko","year":"2022","journal-title":"Ophthalmic Physiol Opt"},{"key":"R21-20250416","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.preteyeres.2018.03.006","article-title":"The primate fovea: structure, function and development.","volume":"66","author":"Bringmann","year":"2018","journal-title":"Prog Retin Eye Res"},{"key":"R22-20250416","first-page":"200","article-title":"Long-term follow-up of visual functions after pediatric cataract extraction and intraocular lens implantation.","volume":"41","author":"Lai","year":"2005","journal-title":"Zhonghua Yan Ke Za Zhi"},{"key":"R23-20250416","doi-asserted-by":"crossref","first-page":"1581","DOI":"10.1016\/j.ophtha.2020.04.046","article-title":"Complications at 10 years of follow-up in the infant aphakia treatment study.","volume":"127","author":"Plager","year":"2020","journal-title":"Ophthalmology"},{"key":"R24-20250416","doi-asserted-by":"crossref","first-page":"3074","DOI":"10.1167\/iovs.04-1040","article-title":"Axial growth and changes in lenticular and corneal power during emmetropization in infants.","volume":"46","author":"Mutti","year":"2005","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R25-20250416","first-page":"815","article-title":"Axial length development in children.","volume":"12","author":"Bach","year":"2019","journal-title":"Int J Ophthalmol"},{"key":"R26-20250416","doi-asserted-by":"crossref","first-page":"873","DOI":"10.1111\/j.1755-3768.1971.tb05939.x","article-title":"The sagittal growth of the eye. IV. Ultrasonic measurement of the axial length of the eye from birth to puberty.","volume":"49","author":"Larsen","year":"1971","journal-title":"Acta Ophthalmol (Copenh)"},{"key":"R27-20250416","doi-asserted-by":"crossref","first-page":"918","DOI":"10.1136\/bjo.80.10.918","article-title":"Reappraisal of the human ocular growth curve in fetal life, infancy, and early childhood.","volume":"80","author":"Fledelius","year":"1996","journal-title":"Br J Ophthalmol"},{"key":"R28-20250416","first-page":"102","article-title":"Relationship between birth month and corneal radius or axial length.","volume":"117","author":"Matsuda","year":"2013","journal-title":"Nippon Ganka Gakkai Zasshi"},{"key":"R29-20250416","doi-asserted-by":"crossref","first-page":"1026","DOI":"10.1001\/archopht.1986.01050190084044","article-title":"The rapid change of corneal curvature in the neonatal period and infancy.","volume":"104","author":"Inagaki","year":"1986","journal-title":"Arch Ophthalmol"},{"key":"R30-20250416","doi-asserted-by":"crossref","first-page":"1296","DOI":"10.1016\/S0161-6420(92)31812-3","article-title":"Corneal diameter, axial length, and intraocular pressure in premature infants.","volume":"99","author":"Tucker","year":"1992","journal-title":"Ophthalmology"},{"key":"R31-20250416","doi-asserted-by":"crossref","first-page":"90","DOI":"10.4274\/tjo.galenos.2023.56252","article-title":"Management of contact lenses and visual development in pediatric aphakia.","volume":"54","author":"\u015eeng\u00f6r","year":"2024","journal-title":"Turk J Ophthalmol"},{"key":"R33-20250416","first-page":"120","article-title":"Optical and structural development of the crystalline lens in childhood.","volume":"39","author":"Mutti","year":"1998","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R34-20250416","doi-asserted-by":"crossref","first-page":"4501","DOI":"10.1364\/BOE.6.004501","article-title":"Calculation of crystalline lens power using a modification of the Bennett method.","volume":"6","author":"Hernandez","year":"2015","journal-title":"Biomed Opt Express"},{"key":"R35-20250416","doi-asserted-by":"crossref","first-page":"352","DOI":"10.1016\/S0161-6420(79)35503-8","article-title":"Defects of vision through aphakic spectacle lenses.","volume":"86","author":"Dabezies","year":"1979","journal-title":"Ophthalmology"},{"key":"R36-20250416","first-page":"71","article-title":"Optical correction of aphakia in children.","volume":"9","author":"Baradaran-Rafii","year":"2014","journal-title":"J Ophthalmic Vis Res"},{"key":"R37-20250416","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1016\/j.jaapos.2023.08.001","article-title":"What we have learned from the infant aphakia treatment study: the 49th Annual Frank D. Costenbader lecture.","volume":"27","author":"Lambert","year":"2023","journal-title":"J AAPOS"},{"key":"R38-20250416","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1001\/archophthalmol.2009.350","article-title":"The infant aphakia treatment study: design and clinical measures at enrollment.","volume":"128","author":"Lambert","year":"2010","journal-title":"Arch Ophthalmol"},{"key":"R39-20250416","doi-asserted-by":"crossref","first-page":"1858","DOI":"10.1038\/s41433-018-0191-3","article-title":"Long-term results of secondary intraocular lens implantation in children under 30 months of age.","volume":"32","author":"Koch","year":"2018","journal-title":"Eye (Lond)"},{"key":"R40-20250416","doi-asserted-by":"crossref","first-page":"720","DOI":"10.1016\/j.ajo.2015.01.002","article-title":"Complications and visual outcomes after secondary intraocular lens implantation in children.","volume":"159","author":"Shenoy","year":"2015","journal-title":"Am J Ophthalmol"},{"key":"R41-20250416","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1080\/08820538.2022.2116288","article-title":"Secondary Intraocular Lens Implantation (IOL) in children- what, why, when, and how?","volume":"38","author":"Lalwani","year":"2023","journal-title":"Semin Ophthalmol"},{"key":"R42-20250416","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1016\/j.survophthal.2019.02.012","article-title":"Multifocal versus monofocal intraocular lenses for age-related cataract patients: a system review and meta-analysis based on randomized controlled trials.","volume":"64","author":"Cao","year":"2019","journal-title":"Surv Ophthalmol"},{"key":"R43-20250416","doi-asserted-by":"crossref","first-page":"1373","DOI":"10.1016\/S0161-6420(01)00670-4","article-title":"Multifocal intraocular lenses in children.","volume":"108","author":"Hunter","year":"2001","journal-title":"Ophthalmology"},{"key":"R44-20250416","first-page":"257","article-title":"Influence of intraocular lens material and design on postoperative intracapsular cellular reactivity.","volume":"98","author":"Apple","year":"2000","journal-title":"Trans Am Ophthalmol Soc"},{"key":"R45-20250416","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1097\/00004397-200107000-00013","article-title":"Pediatric cataract surgery and intraocular lens implantation: current techniques, complications, and management.","volume":"41","author":"Pandey","year":"2001","journal-title":"Int Ophthalmol Clin"},{"key":"R46-20250416","doi-asserted-by":"crossref","first-page":"1576","DOI":"10.1016\/S0886-3350(99)00297-7","article-title":"Visual results and postoperative complications of capsular bag versus sulcus fixation of posterior chamber intraocular lenses for traumatic cataract in children.","volume":"25","author":"Pandey","year":"1999","journal-title":"J Cataract Refract Surg"},{"key":"R47-20250416","doi-asserted-by":"crossref","first-page":"25","DOI":"10.3928\/0191-3913-19990101-06","article-title":"Refractive status in children after long-term follow up of cataract surgery with intraocular lens implantation.","volume":"36","author":"Spierer","year":"1999","journal-title":"J Pediatr Ophthalmol Strabismus"},{"key":"R49-20250416","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1016\/j.jcrs.2007.11.026","article-title":"Capsular block syndrome after cataract surgery: Clinical analysis and classification.","volume":"34","author":"Kim","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R50-20250416","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1016\/S0886-3350(13)80910-8","article-title":"Postoperative capsular bag distension.","volume":"18","author":"Holtz","year":"1992","journal-title":"J Cataract Refract Surg"},{"key":"R51-20250416","doi-asserted-by":"crossref","first-page":"1333","DOI":"10.1038\/eye.2013.168","article-title":"Capsular blockage syndrome in a child: a case report.","volume":"27","author":"Medsinge","year":"2013","journal-title":"Eye (Lond)"},{"key":"R52-20250416","doi-asserted-by":"crossref","first-page":"78","DOI":"10.4103\/ijo.IJO_101_21","article-title":"Capsular bag distention syndrome in a child: a case report.","volume":"2","author":"Matalia","year":"2022","journal-title":"Indian Journal of Ophthalmology - Case Reports"},{"key":"R53-20250416","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/0039-6257(84)90113-9","article-title":"Complications of intraocular lenses. A historical and histopathological review.","volume":"29","author":"Apple","year":"1984","journal-title":"Surv Ophthalmol"},{"key":"R54-20250416","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1080\/08820538.2019.1620809","article-title":"Intraocular lens techniques in pediatric eyes with insufficient capsular support: complications and outcomes.","volume":"34","author":"Cheung","year":"2019","journal-title":"Semin Ophthalmol"},{"key":"R55-20250416","doi-asserted-by":"crossref","first-page":"1666","DOI":"10.1016\/j.jcrs.2007.05.016","article-title":"Choice of intraocular lens for pediatric cataract surgery: survey of AAPOS members.","volume":"33","author":"Wilson","year":"2007","journal-title":"J Cataract Refract Surg"},{"key":"R56-20250416","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1097\/00055735-200102000-00006","article-title":"Intraocular lens implantation in children.","volume":"12","author":"Ahmadieh","year":"2001","journal-title":"Curr Opin Ophthalmol"},{"key":"R57-20250416","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1097\/ICU.0000000000001095","article-title":"How do intraocular lens materials influence the outcome of cataract surgery?","volume":"36","author":"Grzybowski","year":"2025","journal-title":"Curr Opin Ophthalmol"},{"key":"R58-20250416","doi-asserted-by":"crossref","first-page":"3025","DOI":"10.4103\/ijo.IJO_985_20","article-title":"Comparison of an aspheric monofocal intraocular lens with the new generation monofocal lens using defocus curve.","volume":"68","author":"Yangzes","year":"2020","journal-title":"Indian J Ophthalmol"},{"key":"R59-20250416","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/S0886-3350(99)00333-8","article-title":"Silicone intraocular lens implantation in children: preliminary results.","volume":"26","author":"Pavlovic","year":"2000","journal-title":"J Cataract Refract Surg"},{"key":"R61-20250416","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1097\/APO.0000000000000590","article-title":"Latest development in extended depth-of-focus intraocular lenses: an update.","volume":"12","author":"Megiddo-Barnir","year":"2023","journal-title":"Asia Pac J Ophthalmol (Phila)"},{"key":"R62-20250416","first-page":"CD003169","article-title":"Multifocal versus monofocal intraocular lenses after cataract extraction.","volume":"12","author":"de Silva","year":"2016","journal-title":"Cochrane Database Syst Rev"},{"key":"R63-20250416","doi-asserted-by":"crossref","first-page":"2035","DOI":"10.1016\/j.jcrs.2010.08.015","article-title":"Multifocal intraocular lenses for unilateral cataract in children.","volume":"36","author":"Crist\u00f3bal","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R64-20250416","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1001\/archopht.1985.01050060045020","article-title":"Refractive development of the human eye.","volume":"103","author":"Gordon","year":"1985","journal-title":"Arch Ophthalmol"},{"key":"R65-20250416","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1111\/aos.15805","article-title":"A new strategy to calculate the intraocular lens power in congenital cataracts according to age and axial length at implantation.","volume":"102","author":"Dupessey","year":"2024","journal-title":"Acta Ophthalmol"},{"key":"R66-20250416","doi-asserted-by":"crossref","first-page":"1","DOI":"10.2147\/OPTO.S390994","article-title":"Accuracy of the SRK\/T formula in pediatric cataract surgery.","volume":"15","author":"Irfani","year":"2023","journal-title":"Clin Optom (Auckl)"},{"key":"R67-20250416","doi-asserted-by":"crossref","first-page":"56","DOI":"10.3126\/nepjoph.v6i1.10773","article-title":"Accuracy of intraocular lens power calculation in pediatric cataracts with less than a 20\u2009mm axial length of the eye.","volume":"6","author":"Joshi","year":"2014","journal-title":"Nepal J Ophthalmol"},{"key":"R68-20250416","doi-asserted-by":"crossref","first-page":"1242","DOI":"10.1038\/eye.2016.171","article-title":"Comparison of IOL power calculation formulae for pediatric eyes.","volume":"30","author":"Vasavada","year":"2016","journal-title":"Eye (Lond)"},{"key":"R69-20250416","doi-asserted-by":"crossref","first-page":"2309","DOI":"10.1007\/s00417-024-06401-4","article-title":"Refractive predictive errors using Barrett II, Hoffer-Q, and SRKT formulae for pediatric IOL implantation.","volume":"262","author":"Shmueli","year":"2024","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R70-20250416","doi-asserted-by":"crossref","first-page":"3313","DOI":"10.1038\/s41433-023-02510-2","article-title":"A Bayesian network meta-analysis on comparisons of intraocular lens power calculation methods for paediatric cataract eyes.","volume":"37","author":"Hong","year":"2023","journal-title":"Eye (Lond)"},{"key":"R71-20250416","doi-asserted-by":"crossref","first-page":"4400","DOI":"10.3390\/jcm13154400","article-title":"Intraocular lens power calculation formulas in children- a systematic review.","volume":"13","author":"Stopyra","year":"2024","journal-title":"J Clin Med"},{"key":"R72-20250416","doi-asserted-by":"crossref","first-page":"2139","DOI":"10.4103\/IJO.IJO_3191_22","article-title":"Intraocular lens formula calculation in pediatric eyes: do we have an answer? A retrospective comparison between Sanders-Retzlaff-Kraff II and Barret\u2019sformula.","volume":"71","author":"Badakere","year":"2023","journal-title":"Indian J Ophthalmol"},{"key":"R73-20250416","doi-asserted-by":"crossref","first-page":"380","DOI":"10.3341\/kjo.2023.0034","article-title":"Comparison of accuracy of six modern intraocular lens power calculation formulas.","volume":"37","author":"Yoon","year":"2023","journal-title":"Korean J Ophthalmol"},{"key":"R74-20250416","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1097\/j.jcrs.0000000000001433","article-title":"Intraocular lens calculation using the ESCRS online calculator in pediatric eyes undergoing lens extraction.","volume":"50","author":"Lwowski","year":"2024","journal-title":"J Cataract Refract Surg"},{"key":"R75-20250416","doi-asserted-by":"crossref","first-page":"3693","DOI":"10.1007\/s00417-024-06557-z","article-title":"IOL calculation using six formulas in children undergoing lens extraction and primary IOL implantation with and without posterior optic capture.","volume":"262","author":"Lwowski","year":"2024","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R76-20250416","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1001\/archophthalmol.2008.520","article-title":"Pharmacological plus optical penalization treatment for amblyopia: results of a randomized trial.","volume":"127","year":"2009","journal-title":"Arch Ophthalmol"},{"key":"R77-20250416","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1016\/S0161-6420(93)31577-0","article-title":"The efficacy of optical and pharmacological penalization.","volume":"100","author":"Repka","year":"1993","journal-title":"Ophthalmology"},{"key":"R78-20250416","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1016\/S1091-8531(99)70043-1","article-title":"Unilateral intraocular lens implantation during the first six months of life.","volume":"3","author":"Lambert","year":"1999","journal-title":"J AAPOS"},{"key":"R79-20250416","doi-asserted-by":"crossref","first-page":"1454","DOI":"10.1016\/j.ophtha.2019.05.009","article-title":"Intraocular lens implantation during early childhood: a report by the American Academy of Ophthalmology.","volume":"126","author":"Lambert","year":"2019","journal-title":"Ophthalmology"},{"key":"R80-20250416","doi-asserted-by":"crossref","first-page":"1189","DOI":"10.1016\/j.ophtha.2019.03.011","article-title":"Outcomes of unilateral cataracts in infants and toddlers 7 to 24 months of age: Toddler Aphakia and Pseudophakia Study (TAPS).","volume":"126","author":"Bothun","year":"2019","journal-title":"Ophthalmology"},{"key":"R81-20250416","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1016\/j.jaapos.2006.11.003","article-title":"Pediatric cataract extraction with intraocular lens implantation: visual acuity outcome when measured at age four years and older.","volume":"11","author":"Ledoux","year":"2007","journal-title":"J AAPOS"},{"key":"R82-20250416","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1111\/j.1755-3768.2010.01872.x","article-title":"Long-term results of bilateral congenital cataract treated with early cataract surgery, aphakic glasses and secondary IOL implantation.","volume":"90","author":"Kim","year":"2012","journal-title":"Acta Ophthalmol"},{"key":"R83-20250416","doi-asserted-by":"crossref","first-page":"77","DOI":"10.55730\/1300-0144.5560","article-title":"Primary versus secondary intraocular lens implantation following removal of congenital\/developmental cataracts: outcomes after acts: outcomes after at least 4 years.","volume":"53","author":"Kaplan","year":"2023","journal-title":"Turk J Med Sci"},{"key":"R84-20250416","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1111\/aos.13603","article-title":"Axial length growth and the risk of developing myopia in European children.","volume":"96","author":"Tideman","year":"2018","journal-title":"Acta Ophthalmol"},{"issue":"Suppl 1","key":"R85-20250416","doi-asserted-by":"crossref","first-page":"618","DOI":"10.1016\/S0886-3350(97)80043-0","article-title":"Choice of lens and dioptric power in pediatric pseudophakia.","volume":"23","author":"Dahan","year":"1997","journal-title":"J Cataract Refract Surg"},{"key":"R86-20250416","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1016\/S0002-9394(98)00247-5","article-title":"Refractive changes after pediatric intraocular lens implantation.","volume":"126","author":"Enyedi","year":"1998","journal-title":"Am J Ophthalmol"},{"key":"R87-20250416","doi-asserted-by":"crossref","first-page":"1905","DOI":"10.2147\/OPTH.S176057","article-title":"Long-term outcomes of intended undercorrection intraocular lens implantation in pediatric cataract.","volume":"12","author":"Lekskul","year":"2018","journal-title":"Clin Ophthalmol"},{"key":"R88-20250416","doi-asserted-by":"crossref","first-page":"592","DOI":"10.1016\/S0886-3350(13)80644-X","article-title":"Intraocular lens implantation in infants with congenital cataracts.","volume":"20","author":"Vasavada","year":"1994","journal-title":"J Cataract Refract Surg"},{"key":"R89-20250416","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1016\/j.ajo.2019.04.018","article-title":"A model to predict postoperative axial length in children undergoing bilateral cataract surgery with primary intraocular lens implantation.","volume":"206","author":"Trivedi","year":"2019","journal-title":"Am J Ophthalmol"},{"key":"R90-20250416","doi-asserted-by":"crossref","first-page":"730","DOI":"10.1016\/j.ophtha.2017.01.010","article-title":"Globe axial length growthat age 5 years in the infant aphakia treatment study.","volume":"124","author":"Wilson","year":"2017","journal-title":"Ophthalmology"},{"key":"R91-20250416","doi-asserted-by":"crossref","first-page":"822","DOI":"10.1016\/j.ophtha.2016.12.040","article-title":"Myopic shift 5 years after intraocular lens implantation in the infant aphakia treatment study.","volume":"124","author":"Weakley","year":"2017","journal-title":"Ophthalmology"},{"key":"R92-20250416","doi-asserted-by":"crossref","first-page":"810","DOI":"10.1016\/S0886-3350(01)01156-7","article-title":"Refractive change in pediatric pseudophakia: 6-year follow-up.","volume":"28","author":"Plager","year":"2002","journal-title":"J Cataract Refract Surg"},{"key":"R93-20250416","doi-asserted-by":"crossref","first-page":"1252","DOI":"10.1016\/j.ajo.2013.07.014","article-title":"Predictability of intraocular lens power calculation formulae in infantile eyes with unilateral congenital cataract: results from the Infant Aphakia Treatment Study.","volume":"156","author":"Vanderveen","year":"2013","journal-title":"Am J Ophthalmol"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000042072","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,16]],"date-time":"2025-04-16T12:01:00Z","timestamp":1744804860000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000042072"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,4]]},"references-count":89,"journal-issue":{"issue":"14","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000042072","relation":{},"ISSN":["1536-5964"],"issn-type":[{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,4]]}}}