{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,12]],"date-time":"2026-11-12T23:29:21Z","timestamp":1794526161052,"version":"4.9.1"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"18","license":[{"start":{"date-parts":[[2025,5,2]],"date-time":"2025-05-02T00:00:00Z","timestamp":1746144000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,5,2]]},"abstract":"<jats:p>To evaluate whether bedside ultrasonographic measurement of optic nerve sheath diameter (ONSD) can assist in the diagnosis of hypertensive emergency and predict hospitalization in patients presenting to the emergency department (ED) with hypertensive crisis. This prospective observational study enrolled adult patients presenting with systolic BP\u2005&gt;\u2005180\u2009mm Hg and\/or diastolic BP\u2005&gt;\u2005120\u2009mm Hg. ONSD was measured on admission and repeated after blood pressure was reduced to target levels. Diagnostic performance was assessed using ROC analysis. A total of 112 patients with hypertensive crisis were included, and 22.3% (n\u2005=\u200525) were diagnosed with hypertensive emergency. The mean ONSD in these patients (5.99\u2005\u00b1\u20050.65\u2009mm) was significantly higher than in those with hypertensive urgency (5.11\u2005\u00b1\u20050.57\u2009mm) (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2005&lt;\u2005.001). Among 31 hospitalized patients, the mean ONSD (5.83\u2005\u00b1\u20050.71\u2009mm) was also significantly higher than in those not hospitalized (5.11\u2005\u00b1\u20050.57\u2009mm) (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2005&lt;\u2005.001). ROC analysis showed good diagnostic performance for predicting hypertensive emergency, with the optimal ONSD cutoff identified as 5.8\u2009mm (sensitivity: 68%, specificity: 93.1%, +LR: 9.86, \u2212LR: 0.34). ONSD measurement is a rapid, noninvasive tool that may aid in early identification of hypertensive emergency and in predicting hospital admission. Its routine use in the ED could facilitate timely intervention and decision-making.<\/jats:p>","DOI":"10.1097\/md.0000000000042361","type":"journal-article","created":{"date-parts":[[2025,5,5]],"date-time":"2025-05-05T22:48:30Z","timestamp":1746485310000},"page":"e42361","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["The value of optic nerve sheath measurement in patients presenting to the emergency department with hypertensive crisis"],"prefix":"10.1097","volume":"104","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8722-5402","authenticated-orcid":false,"given":"Faruk","family":"Dan\u0131\u015f","sequence":"first","affiliation":[{"name":"Department of Emergency Medicine, Hacettepe University Faculty of Medicine, Ankara, T\u00fcrkiye"},{"name":"Department of Emergency Medicine, Bolu Abant \u0130zzet Baysal University Medical School, Bolu, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1422-5927","authenticated-orcid":false,"given":"Emre","family":"Kudu","sequence":"additional","affiliation":[{"name":"Department of Emergency Medicine, Hacettepe University Faculty of Medicine, Ankara, T\u00fcrkiye"},{"name":"Department of Emergency Medicine, Marmara University Pendik Training and Research Hospital, \u0130stanbul, T\u00fcrkiye."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6396-6668","authenticated-orcid":false,"given":"Elif","family":"\u00d6zt\u00fcrk \u0130nce","sequence":"additional","affiliation":[{"name":"Department of Emergency Medicine, Hacettepe University Faculty of Medicine, Ankara, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0876-2811","authenticated-orcid":false,"given":"Mehmet Ali","family":"Karaca","sequence":"additional","affiliation":[{"name":"Department of Emergency Medicine, Hacettepe University Faculty of Medicine, Ankara, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8555-0017","authenticated-orcid":false,"given":"B\u00fclent","family":"Erbil","sequence":"additional","affiliation":[{"name":"Department of Emergency Medicine, Hacettepe University Faculty of Medicine, Ankara, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250513","doi-asserted-by":"crossref","first-page":"1269","DOI":"10.1161\/HYP.0000000000000066","article-title":"2017 ACC\/AHA\/AAPA\/ABC\/ACPM\/AGS\/APhA\/ASH\/ASPC\/NMA\/PCNA guideline for the prevention, detection, evaluation, and management of high blood pressure in adults: executive summary: a report of the American College of Cardiology\/American Heart Association task force on clinical practice guidelines.","volume":"71","author":"Whelton","year":"2018","journal-title":"Hypertension"},{"key":"R2-20250513","doi-asserted-by":"crossref","first-page":"2560","DOI":"10.1001\/jama.289.19.2560","article-title":"The seventh report of the joint national committee on prevention, detection, evaluation, and treatment of high blood pressure: the JNC 7 report.","volume":"289","author":"Chobanian","year":"2003","journal-title":"JAMA"},{"key":"R3-20250513","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1227\/NEU.0000000000001432","article-title":"Guidelines for the management of severe traumatic brain injury, fourth edition.","volume":"80","author":"Carney","year":"2017","journal-title":"Neurosurgery"},{"key":"R4-20250513","doi-asserted-by":"crossref","first-page":"1357","DOI":"10.1016\/j.ajem.2011.09.025","article-title":"Optic nerve ultrasound for the detection of elevated intracranial pressure in the hypertensive patient.","volume":"30","author":"Roque","year":"2012","journal-title":"Am J Emerg Med"},{"key":"R5-20250513","doi-asserted-by":"crossref","first-page":"40","DOI":"10.4274\/eajem.galenos.2019.71463","article-title":"Measurement of optic nerve sheath diameter to detect increased intracranial pressure in hypertensive patients.","volume":"19","author":"Dikmeta\u015f","year":"2020","journal-title":"Eurasian J Emerg Med"},{"key":"R6-20250513","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1007\/s00134-008-1371-6","article-title":"Year in review in intensive care medicine, 2008: I. Brain injury and neurology, renal failure and endocrinology, metabolism and nutrition, sepsis, infections and pneumonia.","volume":"35","author":"Antonelli","year":"2009","journal-title":"Intensive Care Med"},{"key":"R7-20250513","doi-asserted-by":"crossref","first-page":"1059","DOI":"10.1007\/s00134-011-2224-2","article-title":"Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis.","volume":"37","author":"Dubourg","year":"2011","journal-title":"Intensive Care Med"},{"key":"R8-20250513","doi-asserted-by":"crossref","first-page":"1284","DOI":"10.1007\/s00134-018-5305-7","article-title":"Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis.","volume":"44","author":"Robba","year":"2018","journal-title":"Intensive Care Med"},{"key":"R9-20250513","doi-asserted-by":"crossref","first-page":"124","DOI":"10.20982\/tqmp.10.2.p124","article-title":"Sample size estimation for correlations with pre-specified confidence interval.","volume":"10","author":"Moinester","year":"2014","journal-title":"Quant Methods Psychol"},{"key":"R10-20250513","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1186\/s12883-017-0964-5","article-title":"Assessment of intracranial pressure with ultrasonographic retrobulbar optic nerve sheath diameter measurement.","volume":"17","author":"Liu","year":"2017","journal-title":"BMC Neurol"},{"key":"R11-20250513","doi-asserted-by":"crossref","first-page":"731","DOI":"10.3171\/jns.2006.104.5.731","article-title":"Predictive value of initial computerized tomography scan, intracranial pressure, and state of autoregulation in patients with traumatic brain injury.","volume":"104","author":"Hiler","year":"2006","journal-title":"J Neurosurg"},{"key":"R12-20250513","doi-asserted-by":"crossref","first-page":"1292","DOI":"10.1007\/s00415-002-0844-8","article-title":"Discrepancies between brain CT imaging and severely raised intracranial pressure proven by ventriculostomy in adults with pneumococcal meningitis.","volume":"249","author":"Winkler","year":"2002","journal-title":"J Neurol"},{"key":"R13-20250513","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1016\/j.annemergmed.2008.12.013","article-title":"Emergency ultrasound guidelines.","volume":"53","year":"2009","journal-title":"Ann Emerg Med"},{"key":"R14-20250513","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1016\/j.jemermed.2014.09.060","article-title":"Accuracy of optic nerve sheath diameter measurement by emergency physicians using bedside ultrasound.","volume":"48","author":"Hassen","year":"2015","journal-title":"J Emerg Med"},{"key":"R15-20250513","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1111\/j.1553-2712.2007.00031.x","article-title":"Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure.","volume":"15","author":"Kimberly","year":"2008","journal-title":"Acad Emerg Med"},{"key":"R16-20250513","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1197\/aemj.10.4.376","article-title":"Elevated intracranial pressure detected by bedside emergency ultrasonography of the optic nerve sheath.","volume":"10","author":"Blaivas","year":"2003","journal-title":"Acad Emerg Med"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000042361","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,13]],"date-time":"2025-05-13T22:06:10Z","timestamp":1747173970000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000042361"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,2]]},"references-count":16,"journal-issue":{"issue":"18","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000042361","relation":{},"ISSN":["1536-5964"],"issn-type":[{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,2]]}}}