{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,9]],"date-time":"2025-06-09T21:40:10Z","timestamp":1749505210016,"version":"3.41.0"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"23","license":[{"start":{"date-parts":[[2025,6,6]],"date-time":"2025-06-06T00:00:00Z","timestamp":1749168000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Liaoning Province Natural Science Foundation of China","award":["2023-MSLH-364"],"award-info":[{"award-number":["2023-MSLH-364"]}]},{"name":"Independent Research Project from General Hospital of Northern Theatre Command","award":["ZZKY2024062"],"award-info":[{"award-number":["ZZKY2024062"]}]},{"name":"Liaoning Province Natural Science Foundation of China","award":["2021JH2\/10300057"],"award-info":[{"award-number":["2021JH2\/10300057"]}]},{"name":"Shenyang Municipal Science and Technology Foundation","award":["22-321-32-07"],"award-info":[{"award-number":["22-321-32-07"]}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,6,6]]},"abstract":"<jats:p>This retrospective study aimed to compare the safety and efficacy of a new minimally invasive osteosynthesis technique with those of conventional open surgery for transverse patellar fractures. Between January 2016 and December 2022, a total of 138 patients with transverse patellar fractures who underwent osteosynthesis with either minimally invasive osteosynthesis technique (MIOT) or open reduction and internal fixation (ORIF) were enrolled and retrospectively analyzed. The outcomes were assessed for 67 patients in the MIOT group (mean age: 46.2\u2005\u00b1\u200515.8 years old, mean follow-up: 26.4\u2005\u00b1\u20055.1 months) and 51 patients in the ORIF group (mean age: 43.7\u2005\u00b1\u200513.4 years old, mean follow-up: 25.1\u2005\u00b1\u20054.8 months). Clinical outcomes, including surgical time, blood loss, bony union time, final range of motion involving knee extension and flexion, Bostman score, visual analogue scale (VAS), and complications, were measured over a minimum follow-up period of 24 months. The surgical time in the MIOT group was shorter than that in the ORIF group (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2005=\u2005.001). The blood loss in the MIOT group was significantly less than that in the ORIF group (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2005&lt;\u2005.0001). At the 2-year follow-up, all fractures had healed. The mean union time in the MIOT group was shorter than that in the ORIF group (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2005=\u2005.002). The MIOT group also exhibited significantly better flexion (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2005=\u2005.001) and a higher Bostman score (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2005=\u2005.0065), compared with the ORIF group. The mean VAS was significantly lower in the MIOT group than that in the ORIF group (<jats:italic toggle=\"yes\">P<\/jats:italic>\u2005&lt;\u2005.0001). The MIOT group had a lower complication rate, including delayed wound healing and implant irritation, as well as an overall lower complication rate. The MIOT method proved to be a reproducibly reliable approach, offering lower surgical trauma, improved functional outcomes, and a lower incidence of complications compared with the conventional open surgical technique for transverse patellar fractures. It may be a prudent choice for treating transverse patellar fractures.<\/jats:p>","DOI":"10.1097\/md.0000000000042397","type":"journal-article","created":{"date-parts":[[2025,6,9]],"date-time":"2025-06-09T21:02:46Z","timestamp":1749502966000},"page":"e42397","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of a minimally invasive osteosynthesis technique with open surgical technique for transverse patellar fractures"],"prefix":"10.1097","volume":"104","author":[{"given":"Xiang-Yu","family":"Ma","sequence":"first","affiliation":[{"name":"Department of Orthopedics, General Hospital of Northern Theatre Command, Shenyang, Liaoning Province, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dong","family":"Cui","sequence":"additional","affiliation":[{"name":"Department of Cardiology, No.967 Hospital of PLA Joint Logistics Support Force, Dalian, Liaoning Province, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jia-Lin","family":"Sun","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, General Hospital of Northern Theatre Command, Shenyang, Liaoning Province, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hong","family":"Yuan","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, General Hospital of Northern Theatre Command, Shenyang, Liaoning Province, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bing","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, General Hospital of Northern Theatre Command, Shenyang, Liaoning Province, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Da-Peng","family":"Zhou","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, General Hospital of Northern Theatre Command, Shenyang, Liaoning Province, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7567-9300","authenticated-orcid":false,"given":"Hai-Long","family":"Yu","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, General Hospital of Northern Theatre Command, Shenyang, Liaoning Province, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tian-Yu","family":"Han","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, General Hospital of Northern Theatre Command, Shenyang, Liaoning Province, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250609","doi-asserted-by":"crossref","first-page":"2287","DOI":"10.1016\/j.injury.2019.10.016","article-title":"Changes in patellar fracture characteristics: a multicenter retrospective analysis of 1596 patellar fracture cases between 2003 and 2017.","volume":"50","author":"Byun","year":"2019","journal-title":"Injury"},{"key":"R2-20250609","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/S0020-1383(00)00170-4","article-title":"Clinical experience of patellar fracture fixation using metal wire or non-absorbable polyester \u2013 a study of 37 cases.","volume":"32","author":"Gosal","year":"2001","journal-title":"Injury"},{"key":"R3-20250609","first-page":"w20165","article-title":"Practical guidelines for the treatment of patellar fractures in adults.","volume":"150","author":"Steinmetz","year":"2020","journal-title":"Swiss Med Wkly"},{"key":"R4-20250609","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1186\/s12938-019-0680-z","article-title":"Biomechanical evaluation of patellar tendon repair using Krackow suture technique.","volume":"18","author":"Yen","year":"2019","journal-title":"Biomed Eng Online"},{"key":"R5-20250609","first-page":"97","article-title":"Fractures of the patella.","volume":"43","author":"Carpenter","year":"1994","journal-title":"Instr Course Lect"},{"key":"R6-20250609","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1097\/00005131-199707000-00009","article-title":"Biomechanical evaluation of current patella fracture fixation techniques.","volume":"11","author":"Carpenter","year":"1997","journal-title":"J Orthop Trauma"},{"key":"R7-20250609","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1097\/00005131-200502000-00008","article-title":"Complete exposure of the articular surface for fixation of patellar fractures.","volume":"19","author":"Gardner","year":"2005","journal-title":"J Orthop Trauma"},{"key":"R8-20250609","first-page":"Doc01","article-title":"Current concepts review: fractures of the patella.","volume":"5","author":"Gwinner","year":"2016","journal-title":"GMS Interdiscip Plast Reconstr Surg DGPW"},{"key":"R9-20250609","doi-asserted-by":"crossref","first-page":"e96 1","DOI":"10.2106\/JBJS.L.00012","article-title":"Outcomes after operative fixation of complete articular patellar fractures: assessment of functional impairment.","volume":"95","author":"Lazaro","year":"2013","journal-title":"J Bone Joint Surg Am"},{"key":"R10-20250609","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1055\/s-0038-1676515","article-title":"The comparison of postoperative outcomes open and closed reduction for patellar fractures.","volume":"33","author":"Lee","year":"2020","journal-title":"J Knee Surg"},{"key":"R11-20250609","doi-asserted-by":"crossref","first-page":"949","DOI":"10.1007\/s00402-010-1241-x","article-title":"Arthroscopically assisted percutaneous osteosynthesis of displaced transverse patellar fractures with figure-eight wiring through paired cannulated screws.","volume":"131","author":"Chiang","year":"2011","journal-title":"Arch Orthop Trauma Surg"},{"key":"R12-20250609","doi-asserted-by":"crossref","first-page":"215","DOI":"10.5792\/ksrr.2013.25.4.215","article-title":"Percutaneous cannulated screws with tension band wiring technique in patella fractures.","volume":"25","author":"Cho","year":"2013","journal-title":"Knee Surg Relat Res"},{"key":"R13-20250609","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1186\/s12891-015-0719-7","article-title":"Comparison of the outcomes of cannulated screws vs. modified tension band wiring fixation techniques in the management of mildly displaced patellar fractures.","volume":"16","author":"Lin","year":"2015","journal-title":"BMC Musculoskelet Disord"},{"key":"R14-20250609","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1016\/j.cjtee.2023.04.005","article-title":"Comparison of a minimally invasive osteosynthesis technique with conventional open surgery for transverse patellar fractures.","volume":"26","author":"Yao","year":"2023","journal-title":"Chin J Traumatol"},{"key":"R15-20250609","doi-asserted-by":"crossref","first-page":"1087","DOI":"10.1016\/j.otsr.2017.04.010","article-title":"Arthroscopically assisted fixation is a reliable option for patellar fractures: a literature review.","volume":"103","author":"Cerciello","year":"2017","journal-title":"Orthop Traumatol Surg Res"},{"key":"R16-20250609","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1007\/s00402-017-2807-7","article-title":"Comminuted inferior pole fracture of patella can be successfully treated with rim-plate-augmented separate vertical wiring.","volume":"138","author":"Cho","year":"2018","journal-title":"Arch Orthop Trauma Surg"},{"key":"R17-20250609","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1111\/os.13539","article-title":"Treating inferior pole fracture of patella with hand plating system: first clinical results.","volume":"15","author":"Ma","year":"2023","journal-title":"Orthop Surg"},{"issue":"Suppl 3","key":"R18-20250609","doi-asserted-by":"crossref","first-page":"S50","DOI":"10.1016\/j.injury.2020.01.012","article-title":"Minimally invasive osteosynthesis technique in the treatment of transverse patellar fractures in the elderly.","volume":"51","author":"Vicenti","year":"2020","journal-title":"Injury"},{"key":"R19-20250609","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1016\/j.jcma.2011.05.008","article-title":"Comparison of a minimally invasive technique with open tension band wiring for displaced transverse patellar fractures.","volume":"74","author":"Chiang","year":"2011","journal-title":"J Chin Med Assoc"},{"key":"R20-20250609","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1186\/s13018-021-02612-1","article-title":"Comparison of minimally invasive percutaneous fixation and open reduction internal fixation for patella fractures: a meta-analysis.","volume":"16","author":"Lo","year":"2021","journal-title":"J Orthop Surg Res"},{"key":"R21-20250609","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/j.knee.2008.07.010","article-title":"Arthroscopic-assisted reduction and stabilization of transverse fractures of the patella.","volume":"16","author":"El-Sayed","year":"2009","journal-title":"Knee"},{"key":"R22-20250609","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1097\/00003086-200108000-00010","article-title":"Arthroscopic-assisted percutaneous stabilization of patellar fractures.","volume":"389","author":"Turgut","year":"2001","journal-title":"Clin Orthop Relat Res"},{"key":"R23-20250609","doi-asserted-by":"crossref","first-page":"2361","DOI":"10.1007\/s11999-013-2932-8","article-title":"Comparison of the cable pin system with conventional open surgery for transverse patella fractures.","volume":"471","author":"Mao","year":"2013","journal-title":"Clin Orthop Relat Res"},{"key":"R24-20250609","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/j.cjtee.2021.02.009","article-title":"Comparison of the clinical efficacy of different fixation systems for the treatment of transverse patellar fractures.","volume":"24","author":"Bai","year":"2021","journal-title":"Chin J Traumatol"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000042397","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,9]],"date-time":"2025-06-09T21:02:49Z","timestamp":1749502969000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000042397"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,6]]},"references-count":24,"journal-issue":{"issue":"23","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000042397","relation":{},"ISSN":["1536-5964"],"issn-type":[{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,6]]}}}