{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T09:08:45Z","timestamp":1792487325973,"version":"4.5.0"},"reference-count":37,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"25","license":[{"start":{"date-parts":[[2025,6,20]],"date-time":"2025-06-20T00:00:00Z","timestamp":1750377600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,6,20]]},"abstract":"<jats:sec>\n                    <jats:title>Rationale:<\/jats:title>\n                    <jats:p>Vascular access is a critical component of care in the neonatal intensive care unit, especially for nutritional support and medication administration. While umbilical vein catheters are commonly used during the first few days of life, peripherally inserted central catheters (PICCs) become the preferred method of central venous access thereafter. However, malpositioning of PICCs, particularly when the tip lies within or in close proximity to the right atrium, may lead to severe complications such as pericardial effusion and cardiac tamponade, especially in extremely low birth weight infants.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Patient concerns:<\/jats:title>\n                    <jats:p>Two extremely low birth weight preterm infants experienced sudden clinical deterioration following PICC insertion, raising concerns about catheter-related complications.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Diagnoses:<\/jats:title>\n                    <jats:p>Both infants were diagnosed with cardiac tamponade secondary to pericardial effusion caused by PICC malposition, with the catheter tip located in or near the right atrium.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Interventions:<\/jats:title>\n                    <jats:p>In both cases, emergency pericardiocentesis was attempted after echocardiographic confirmation of pericardial effusion and clinical signs of tamponade. Despite resuscitative efforts, both infants succumbed to the complication.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Outcomes:<\/jats:title>\n                    <jats:p>The outcome was fatal in both cases and confirmed catheter malposition as the underlying cause of pericardial effusion and cardiac tamponade.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Lessons:<\/jats:title>\n                    <jats:p>To prevent fatal complications such as cardiac tamponade, PICCs should be positioned in safe area. Proper placement in the superior vena cava should be confirmed and maintained. Regular verification of catheter tip position and minimizing unnecessary repositioning are essential for preventing catheter-related adverse events in vulnerable preterm infants.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/md.0000000000042822","type":"journal-article","created":{"date-parts":[[2025,6,23]],"date-time":"2025-06-23T17:01:19Z","timestamp":1750698079000},"page":"e42822","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Two fatal case reports of cardiac tamponade caused by pericardial effusion due to misplaced peripherally inserted central catheters in extremely low birth weight infants"],"prefix":"10.1097","volume":"104","author":[{"given":"Jeongmin","family":"Shin","sequence":"first","affiliation":[{"name":"Department of Pediatrics, Seoul St. Mary\u2019s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sae Yun","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, Seoul St. Mary\u2019s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9083-2414","authenticated-orcid":false,"given":"Young-Ah","family":"Youn","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, Seoul St. Mary\u2019s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20260613","first-page":"163","article-title":"Pericardial effusion and cardiac tamponade in neonates: sudden unexpected death associated with total parenteral nutrition via central venous catheterization.","volume":"43","author":"Warren","year":"2013","journal-title":"Ann Clin Lab Sci"},{"key":"R2-20260613","first-page":"230","article-title":"Assessment of peripherally inserted central catheters in neonates.","volume":"2","author":"Pettit","year":"2002","journal-title":"Adv Neonatal Care"},{"issue":"1 Pt 1","key":"R3-20260613","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1542\/peds.110.1.137","article-title":"Pericardial effusion and tamponade in infants with central catheters.","volume":"110","author":"Nowlen","year":"2002","journal-title":"Pediatrics"},{"key":"R4-20260613","first-page":"54","article-title":"Risk factors for peripherally inserted central catheter malposition in preterm infants: a multicenter retrospective study.","volume":"24","author":"Liu","year":"2024","journal-title":"BMC Pediatr"},{"key":"R5-20260613","first-page":"987512","article-title":"Complications of peripherally inserted central catheters in neonates: a 10-year retrospective study.","volume":"10","author":"Ding","year":"2022","journal-title":"Front Pediatr"},{"key":"R6-20260613","first-page":"343","article-title":"Hospital-wide surveillance of catheter-related bloodstream infection: from the ICU to outpatient and home care settings.","volume":"11","author":"Zingg","year":"2011","journal-title":"Lancet Infect Dis"},{"key":"R7-20260613","doi-asserted-by":"crossref","first-page":"13679","DOI":"10.1038\/s41598-022-17820-w","article-title":"Catheter-related blood stream infections in infants hospitalized in neonatal intensive care units: a single center study.","volume":"12","author":"Kochanowicz","year":"2022","journal-title":"Sci Rep"},{"key":"R8-20260613","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1093\/ejechocard\/jer181","article-title":"Targeted neonatal echocardiography in the neonatal intensive care unit: practice guidelines and recommendations for training. Writing group of the American Society of Echocardiography (ASE) in collaboration with the European Association of Echocardiography (EAE) and the Association for European Pediatric Cardiologists (AEPC).","volume":"12","author":"Mertens","year":"2011","journal-title":"Eur J Echocardiogr"},{"key":"R9-20260613","first-page":"e090111","article-title":"Neonatal pericardial effusion: case report and review of the literature.","volume":"9","author":"Liz","year":"2020","journal-title":"J Pediatr Neonatal Individ Med"},{"key":"R10-20260613","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1007\/s00246-007-9014-1","article-title":"Etiology, management, and outcome of pediatric pericardial effusions.","volume":"29","author":"K\u00fchn","year":"2008","journal-title":"Pediatr Cardiol"},{"key":"R11-20260613","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1016\/j.jicc.2015.04.002","article-title":"Massive pericardial effusion in a neonate.","volume":"5","author":"Narayanapillai","year":"2015","journal-title":"J Indian Coll Cardiol"},{"key":"R12-20260613","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/j.clp.2007.11.007","article-title":"Complications of vascular catheters in the neonatal intensive care unit.","volume":"35","author":"Ramasethu","year":"2008","journal-title":"Clin Perinatol"},{"key":"R13-20260613","doi-asserted-by":"crossref","first-page":"1359","DOI":"10.1080\/14767058.2017.1403581","article-title":"Role of ultrasound in confirmation of endotracheal tube in neonates: a review.","volume":"32","author":"Sharma","year":"2019","journal-title":"J Matern Fetal Neonatal Med"},{"key":"R14-20260613","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1093\/bjr\/tqae218","article-title":"Value of projectional imaging relative to cross-sectional imaging to assess catheter tip position in the superior vena cava: evaluation of reader variability.","volume":"98","author":"Gullo","year":"2025","journal-title":"Br J Radiol"},{"key":"R15-20260613","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1055\/s-0039-1694760","article-title":"Ultrasound to localize the peripherally inserted central catheter tip position in newborn infants.","volume":"38","author":"Ren","year":"2021","journal-title":"Am J Perinatol"},{"key":"R16-20260613","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1097\/JPN.0000000000000264","article-title":"Effectiveness of intracavitary electrocardiogram guidance in peripherally inserted central catheter tip placement in neonates.","volume":"31","author":"Zhou","year":"2017","journal-title":"J Perinat Neonatal Nurs"},{"key":"R17-20260613","doi-asserted-by":"crossref","first-page":"694","DOI":"10.1016\/j.ijnurstu.2013.09.002","article-title":"The safety and efficacy of midlines compared to peripherally inserted central catheters for adult cystic fibrosis patients: a retrospective, observational study.","volume":"51","author":"Sharp","year":"2014","journal-title":"Int J Nurs Stud"},{"key":"R18-20260613","first-page":"188","article-title":"Safe placement of central venous catheters. where should the tip of the catheter lie?","volume":"85","author":"Fletcher","year":"2000","journal-title":"Br J Anaesth"},{"key":"R19-20260613","doi-asserted-by":"crossref","first-page":"E28","DOI":"10.1542\/peds.107.2.e28","article-title":"Pediatric peripherally inserted central catheters: complication rates related to catheter tip location.","volume":"107","author":"Racadio","year":"2001","journal-title":"Pediatrics"},{"key":"R20-20260613","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1001\/jamapediatrics.2013.775","article-title":"Risk factors for peripherally inserted central venous catheter complications in children.","volume":"167","author":"Jumani","year":"2013","journal-title":"JAMA Pediatr"},{"key":"R21-20260613","first-page":"e31988","article-title":"Assessment of the tip position of central venous catheters inserted using Peres\u2019 height formula.","volume":"14","author":"\u015eahinkaya","year":"2022","journal-title":"Cureus"},{"key":"R22-20260613","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1038\/jp.2012.112","article-title":"Peripherally inserted central catheter tip position and risk of associated complications in neonates.","volume":"33","author":"Jain","year":"2013","journal-title":"J Perinatol"},{"key":"R23-20260613","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1007\/s00431-008-0704-3","article-title":"Cardiomegaly in a premature neonate after venous umbilical catheterization.","volume":"168","author":"Schlapbach","year":"2009","journal-title":"Eur J Pediatr"},{"key":"R24-20260613","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1007\/s00247-017-3983-x","article-title":"Perforations associated with peripherally inserted central catheters in a neonatal population.","volume":"48","author":"Sertic","year":"2018","journal-title":"Pediatr Radiol"},{"key":"R25-20260613","doi-asserted-by":"crossref","first-page":"1687","DOI":"10.1016\/j.jpedsurg.2009.11.006","article-title":"Pericardial effusion and cardiac tamponade associated with central venous catheters in children: an uncommon but serious and treatable condition.","volume":"45","author":"Weil","year":"2010","journal-title":"J Pediatr Surg"},{"key":"R26-20260613","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1007\/s00431-017-2854-7","article-title":"Dwell times and risk of non-elective removal of 1-French peripherally inserted central catheters according to catheter tip position in very preterm infants.","volume":"176","author":"Erhard","year":"2017","journal-title":"Eur J Pediatr"},{"key":"R27-20260613","doi-asserted-by":"crossref","first-page":"1676","DOI":"10.1007\/s00247-017-3939-1","article-title":"Non-central peripherally inserted central catheters in neonatal intensive care: complication rates and longevity of catheters relative to tip position.","volume":"47","author":"Goldwasser","year":"2017","journal-title":"Pediatr Radiol"},{"key":"R28-20260613","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1053\/adnc.2002.36826","article-title":"Assessment of infants with peripherally inserted central catheters: part 1. Detecting the most frequently occurring complications.","volume":"2","author":"Pettit","year":"2002","journal-title":"Adv Neonatal Care"},{"key":"R29-20260613","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1111\/ped.12033","article-title":"Complications of peripherally inserted central venous catheter in Japanese neonatal intensive care units.","volume":"55","author":"Ohki","year":"2013","journal-title":"Pediatr Int"},{"key":"R30-20260613","doi-asserted-by":"crossref","first-page":"871","DOI":"10.1055\/s-0033-1333672","article-title":"Migration patterns of peripherally inserted central venous catheters at 24 hours postinsertion in neonates.","volume":"30","author":"Srinivasan","year":"2013","journal-title":"Am J Perinatol"},{"key":"R31-20260613","doi-asserted-by":"crossref","first-page":"886450","DOI":"10.3389\/fped.2022.886450","article-title":"Sonographic evaluation of the endotracheal tube position in the neonatal population: a comprehensive review and meta-analysis.","volume":"10","author":"Congedi","year":"2022","journal-title":"Front Pediatr"},{"key":"R32-20260613","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1097\/01.RVI.0000071097.76348.72","article-title":"Central venous catheter tip position: a continuing controversy.","volume":"14","author":"Vesely","year":"2003","journal-title":"J Vasc Interv Radiol"},{"key":"R33-20260613","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1542\/peds.110.1.131","article-title":"Changes in upper extremity position cause migration of peripherally inserted central catheters in neonates.","volume":"110","author":"Nadroo","year":"2002","journal-title":"Pediatrics"},{"key":"R34-20260613","doi-asserted-by":"crossref","first-page":"e18368","DOI":"10.1097\/MD.0000000000018368","article-title":"Intracavitary electrocardiogram guidance for placement of peripherally inserted central catheters in premature infants.","volume":"98","author":"Yang","year":"2019","journal-title":"Medicine (Baltimore)"},{"key":"R35-20260613","doi-asserted-by":"crossref","first-page":"2421","DOI":"10.1007\/s00247-022-05379-7","article-title":"Diagnostic accuracy of ultrasound for localising peripherally inserted central catheter tips in infants in the neonatal intensive care unit: a systematic review and meta-analysis.","volume":"52","author":"Doyle","year":"2022","journal-title":"Pediatr Radiol"},{"key":"R36-20260613","doi-asserted-by":"crossref","first-page":"280","DOI":"10.5301\/JVA.2011.8381","article-title":"The electrocardiographic method for positioning the tip of central venous catheters.","volume":"12","author":"Pittiruti","year":"2011","journal-title":"J Vasc Access"},{"key":"R37-20260613","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1007\/s00431-019-03524-3","article-title":"Effectiveness of intracavitary electrocardiogram-guided peripherally inserted central catheter tip placement in premature infants: a multicentre pre-post intervention study..","volume":"179","author":"Xiao","year":"2020","journal-title":"Eur J Pediatr"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000042822","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T13:01:16Z","timestamp":1781355676000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000042822"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,20]]},"references-count":37,"journal-issue":{"issue":"25","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000042822","relation":{},"ISSN":["1536-5964"],"issn-type":[{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,20]]}}}