{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T19:11:19Z","timestamp":1789153879216,"version":"build-2803163510"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"33","license":[{"start":{"date-parts":[[2025,8,15]],"date-time":"2025-08-15T00:00:00Z","timestamp":1755216000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,8,15]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Hip arthroplasty is a common operation for fragility hip fractures in the elderly. However, the choice of implant, particularly between collared composite beam (CCB) and collarless polished taper-slip (CPTS) femoral stems, may impact postoperative outcomes. In this study, we aimed to systematically review and compare unfavorable postoperative outcomes associated with these 2 stem designs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>We conducted a systematic review and meta-analysis in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Studies indexed in the Medline, Embase, Scopus, and Web of Science databases from their inception dates through December 2023 were included if they reported outcomes comparing collar and collarless femoral stems. Data were extracted and analyzed using a random-effects model for postoperative periprosthetic femoral fractures (PFFs) and reoperations, with results presented as pooled risk ratios (RRs) and 95% confidence intervals (CIs).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Four studies involving 24,623 patients with hip fractures were included (CCB: 10,377; CPTS: 14,246). Most patients were female (69%\u201375%), with a follow-up period of 1 to 3.9 years. The incidence of PFFs was significantly higher in the CPTS group (0.72%) compared to the CCB group (0.14%), corresponding to a pooled RR of 5.34 (95% CI: 2.61\u201310.92). The overall reoperation rates were 4.40% in the CPTS group and 3.30% in the CCB group, with a pooled RR of 1.26 (95% CI: 1.00\u20131.59), indicating a marginally significant increase in reoperation risk associated with CPTS stems.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>While CPTS femoral stems had a higher risk of PFFs in patients with hip fracture, overall reoperation rates were comparable to those experienced with CCB designs. The observed heterogeneity suggests that further high-quality studies with standardized protocols are warranted to reduce variability and refine treatment strategies for hip arthroplasty.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/md.0000000000043717","type":"journal-article","created":{"date-parts":[[2025,8,18]],"date-time":"2025-08-18T19:01:02Z","timestamp":1755543662000},"page":"e43717","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Association between cemented femoral stem design and unfavorable postoperative outcomes in hip fracture patients: A systematic review and meta-analysis"],"prefix":"10.1097","volume":"104","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6730-7486","authenticated-orcid":false,"given":"Chirathit","family":"Anusitviwat","sequence":"first","affiliation":[{"name":"Department of Orthopedics, Faculty of Medicine, Prince of Songkla University, Songkhla, Thailand."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7638-6742","authenticated-orcid":false,"given":"Khanin","family":"Iamthanaporn","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Faculty of Medicine, Prince of Songkla University, Songkhla, Thailand."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1075-0222","authenticated-orcid":false,"given":"Theerawit","family":"Hongnaparak","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Faculty of Medicine, Prince of Songkla University, Songkhla, Thailand."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Varah","family":"Yuenyongviwat","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Faculty of Medicine, Prince of Songkla University, Songkhla, Thailand."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20260911","doi-asserted-by":"crossref","first-page":"S32","DOI":"10.1016\/j.arth.2024.05.064","article-title":"Traumaplasty: when and how to perform acute arthroplasty for fractures around the hip in the elderly patient.","volume":"39","author":"Wolfstadt","year":"2024","journal-title":"J Arthroplasty"},{"key":"R2-20260911","doi-asserted-by":"crossref","first-page":"S192","DOI":"10.1016\/j.jcot.2019.02.009","article-title":"Common hip conditions requiring primary total hip arthroplasty and comparison of their post-operative functional outcomes.","volume":"11","author":"Kumar","year":"2020","journal-title":"J Clin Orthop Trauma"},{"key":"R3-20260911","first-page":"1","article-title":"Femoral neck fractures.","volume":"42","author":"Sandhu","year":"2008","journal-title":"Indian J Orthop"},{"key":"R4-20260911","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1080\/10255842.2010.493513","article-title":"The biomechanical effect of the collar of a femoral stem on total hip arthroplasty.","volume":"14","author":"Jeon","year":"2011","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"R5-20260911","doi-asserted-by":"crossref","first-page":"1654","DOI":"10.1302\/0301-620X.102B12.BJJ-2019-1428.R1","article-title":"The effect of femoral stem collar on implant migration and clinical outcomes following direct anterior approach total hip arthroplasty.","volume":"102-B","author":"Perelgut","year":"2020","journal-title":"Bone Joint J"},{"key":"R6-20260911","doi-asserted-by":"crossref","first-page":"1185","DOI":"10.1002\/jor.23744","article-title":"Influence of collars on the primary stability of cementless femoral stems: a finite element study using a diverse patient cohort.","volume":"36","author":"Al-Dirini","year":"2018","journal-title":"J Orthop Res"},{"key":"R7-20260911","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1016\/S0883-5403(89)80071-3","article-title":"Initial effect of collarless stem stiffness on femoral bone strain.","volume":"4","author":"Diegel","year":"1989","journal-title":"J Arthroplasty"},{"key":"R8-20260911","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1080\/17453674.2019.1574387","article-title":"The design of the cemented stem influences the risk of vancouver type B fractures, but Not of Type C: an analysis of 82,837 Lubinus SPII and exeter polished stems.","volume":"90","author":"Chatziagorou","year":"2019","journal-title":"Acta Orthop"},{"key":"R9-20260911","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1080\/17453674.2019.1624339","article-title":"Reduced periprosthetic fracture rate when changing from a tapered polished stem to an anatomical stem for cemented hip arthroplasty: an observational prospective cohort study with a follow-up of 2 years.","volume":"90","author":"Mohammed","year":"2019","journal-title":"Acta Orthop"},{"key":"R10-20260911","doi-asserted-by":"crossref","first-page":"1565","DOI":"10.1302\/0301-620X.100B12.BJJ-2018-0262.R1","article-title":"More reoperations for periprosthetic fracture after cemented hemiarthroplasty with polished taper-slip stems than after anatomical and straight stems in the treatment of hip fractures: a study from the norwegian hip fracture register 2005 to 2016.","volume":"100-B","author":"Kristensen","year":"2018","journal-title":"Bone Joint J"},{"key":"R11-20260911","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1016\/j.arth.2023.08.068","article-title":"Increased rates of late periprosthetic fractures in larger hydroxyapatite-coated cementless stems: are collared stems a better alternative for total hip arthroplasty?","volume":"39","author":"Tierney","year":"2024","journal-title":"J Arthroplasty"},{"key":"R12-20260911","doi-asserted-by":"crossref","first-page":"S363","DOI":"10.1016\/j.arth.2021.02.012","article-title":"Periprosthetic femur fracture risk: influenced by stem choice, not surgical approach.","volume":"36","author":"Sershon","year":"2021","journal-title":"J Arthroplasty"},{"key":"R13-20260911","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1080\/17453674.2019.1582680","article-title":"Not all cemented hips are the same: a Register-Based (NJR) comparison of taper-slip and composite beam femoral stems.","volume":"90","author":"Kazi","year":"2019","journal-title":"Acta Orthop"},{"key":"R14-20260911","doi-asserted-by":"crossref","first-page":"S598","DOI":"10.1016\/j.arth.2022.02.039","article-title":"Collarless taper slip and collared composite beam stems differ in failure modes and reoperation Rates.","volume":"37","author":"Rames","year":"2022","journal-title":"J Arthroplasty"},{"key":"R15-20260911","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1046\/j.1445-2197.2003.02748.x","article-title":"Methodological Index for Non-Randomized Studies (Minors): development and validation of a new instrument.","volume":"73","author":"Slim","year":"2003","journal-title":"ANZ J Surg"},{"key":"R16-20260911","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1016\/j.ejvs.2016.11.007","article-title":"Venous arterialisation for salvage of critically ischaemic limbs: a systematic review and meta-analysis.","volume":"53","author":"Schreve","year":"2017","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"R17-20260911","doi-asserted-by":"crossref","first-page":"1936","DOI":"10.1111\/os.70077","article-title":"Do meta-analyses of total hip arthroplasty produce reliable results? A systematic review and meta-epidemiological study of statistical methods.","volume":"17","author":"Ramadanov","year":"2025","journal-title":"Orthop Surg"},{"key":"R18-20260911","doi-asserted-by":"crossref","first-page":"257","DOI":"10.3109\/17453674.2016.1162898","article-title":"Substantially higher prevalence of postoperative peri-prosthetic fractures in octogenarians with hip fractures operated with a cemented, polished tapered stem rather than an anatomic stem.","volume":"87","author":"Mukka","year":"2016","journal-title":"Acta Orthop"},{"key":"R19-20260911","doi-asserted-by":"crossref","first-page":"803","DOI":"10.1007\/s00068-019-01263-6","article-title":"Increased risk for postoperative periprosthetic fracture in hip fracture patients with the exeter stem than the anatomic SP2 Lubinus stem.","volume":"47","author":"Mellner","year":"2021","journal-title":"Eur J Trauma Emerg Surg"},{"key":"R20-20260911","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1007\/s00590-021-02948-8","article-title":"Cemented hemiarthroplasty for femoral neck fracture patients: Collarless, Polished Tapered Stem (CPT) versus anatomic matte stem (Lubinus SP2).","volume":"31","author":"Joanroy","year":"2021","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"R21-20260911","doi-asserted-by":"crossref","first-page":"1549","DOI":"10.1016\/j.arth.2011.03.030","article-title":"Does a collar improve the immediate stability of uncemented femoral hip stems in total hip arthroplasty? A bilateral comparative cadaver study.","volume":"26","author":"Demey","year":"2011","journal-title":"J Arthroplasty"},{"key":"R22-20260911","doi-asserted-by":"crossref","first-page":"101140","DOI":"10.1016\/j.artd.2023.101140","article-title":"Primary stability of collared and collarless cementless femoral stems \u2013 a finite element analysis study.","volume":"21","author":"Watanabe","year":"2023","journal-title":"Arthroplast Today"},{"key":"R23-20260911","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1051\/sicotj\/2024003","article-title":"Collared versus collarless hydroxyapatite-coated stems for primary cementless total hip arthroplasty; a systematic review of comparative studies. is there any difference in survival, functional, and radiographic outcomes?","volume":"10","author":"Giovanoulis","year":"2024","journal-title":"SICOT J"},{"key":"R24-20260911","first-page":"239","article-title":"Risk factors for complications in total hip arthroplasty.","volume":"69","author":"Hoyos-Velasco","year":"2025","journal-title":"Rev Esp Cir Ortop Traumatol"},{"key":"R25-20260911","doi-asserted-by":"crossref","first-page":"160","DOI":"10.3390\/jcm13010160","article-title":"Incidence and clinical risk factors of post-operative complications following primary total hip arthroplasty: a 10-year population-based cohort study.","volume":"13","author":"Lin","year":"2023","journal-title":"J Clin Med"},{"key":"R26-20260911","doi-asserted-by":"crossref","first-page":"1832","DOI":"10.1016\/j.arth.2012.04.025","article-title":"Factors independently associated with complications and length of stay after hip arthroplasty: analysis of the national surgical quality improvement program.","volume":"27","author":"O\u2019Malley","year":"2012","journal-title":"J Arthroplasty"},{"key":"R27-20260911","doi-asserted-by":"crossref","first-page":"2363","DOI":"10.1007\/s11999-010-1354-0","article-title":"Factors that predict short-term complication rates after total hip arthroplasty.","volume":"468","author":"Soohoo","year":"2010","journal-title":"Clin Orthop Relat Res"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/MD.0000000000043717","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T19:00:35Z","timestamp":1789153235000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/MD.0000000000043717"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,15]]},"references-count":27,"journal-issue":{"issue":"33","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000043717","relation":{},"ISSN":["1536-5964","0025-7974"],"issn-type":[{"value":"1536-5964","type":"electronic"},{"value":"0025-7974","type":"print"}],"subject":[],"published":{"date-parts":[[2025,8,15]]},"assertion":[{"value":"2025-05-22","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-07-16","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}