{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,11]],"date-time":"2026-11-11T15:49:44Z","timestamp":1794412184615,"version":"4.9.0"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"39","license":[{"start":{"date-parts":[[2025,9,26]],"date-time":"2025-09-26T00:00:00Z","timestamp":1758844800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,9,26]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Maxillary molar distalization is a common treatment approach for Class II malocclusions. This study aimed to compare the effectiveness and side effects of conventional pendulum appliances versus single and double miniscrew-supported pendulum appliances on skeletal and dentoalveolar structures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Thirty patients with skeletal Class I and dental Class II malocclusion were randomly allocated to 3 equal groups (n\u2005=\u200510 each): conventional pendulum appliance (Group 1), single miniscrew-supported pendulum (Group 2), and double miniscrew-supported pendulum (Group 3). Mean ages were 13.6\u2005\u00b1\u20051.2, 14.5\u2005\u00b1\u20051.1, and 14.3\u2005\u00b1\u20051.2 years, respectively. Treatment continued until bilateral Class I molar relationships were achieved. Pre- and post-distalization lateral cephalometric radiographs were analyzed for skeletal and dental changes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The mean distalization period was significantly shorter in Group 3 (6.4\u2005\u00b1\u20050.5 months) compared to Group 2 (7.3\u2005\u00b1\u20050.5 months) and Group 1 (8.0\u2005\u00b1\u20050.7 months) (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005&lt;\u2005.05). All groups exhibited distal molar tipping with upper first molar long-axis angle to maxillary horizontal reference plane (\u00b0) increases of 5.2\u2005\u00b1\u20050.9\u00b0, 6.8\u2005\u00b1\u20051.1\u00b0, and 7.4\u2005\u00b1\u20051.0\u00b0 in Groups 1, 2, and 3, respectively. Incisor protrusion occurred in Groups 1 and 2 (upper central incisor tip to maxillary vertical reference plane (mm) increase: 2.2\u2005\u00b1\u20050.5\u2009mm and 1.5\u2005\u00b1\u20050.4\u2009mm), while Group 3 demonstrated incisor retrusion (\u22120.8\u2005\u00b1\u20050.3\u2009mm) (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005&lt;\u2005.01). Group 3 showed significantly less increase in overjet (0.4\u2005\u00b1\u20050.2\u2009mm) compared to Groups 1 (2.5\u2005\u00b1\u20050.6\u2009mm) and 2 (1.7\u2005\u00b1\u20050.5\u2009mm) (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005&lt;\u2005.01).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The double miniscrew-supported pendulum appliance demonstrated superior clinical efficiency with reduced treatment duration and minimal anchorage loss. This approach provided better control of incisor position during maxillary molar distalization compared to conventional and single miniscrew designs.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/md.0000000000044512","type":"journal-article","created":{"date-parts":[[2025,9,30]],"date-time":"2025-09-30T16:02:34Z","timestamp":1759248154000},"page":"e44512","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Comparative investigation of the effects of conventional and skeletal anchorage pendulum appliances on dentofacial structures"],"prefix":"10.1097","volume":"104","author":[{"ORCID":"https:\/\/orcid.org\/0009-0006-5623-9397","authenticated-orcid":false,"given":"Ayca","family":"Aksoy","sequence":"first","affiliation":[{"name":"Private Practice, Ankara, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8195-2737","authenticated-orcid":false,"given":"Oyku","family":"Ozen","sequence":"additional","affiliation":[{"name":"Private Practice, Ankara, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7852-3758","authenticated-orcid":false,"given":"Murat Kaan","family":"Erdem","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Lokman Hekim University, Faculty of Dentistry, Ankara, Turkey."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R2-20260602","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1034\/j.1600-9975.2000.d01-4.x","article-title":"A rational approach to orthodontic anchorage.","volume":"1","author":"Melsen","year":"2000","journal-title":"Prog Orthod"},{"key":"R3-20260602","first-page":"706","article-title":"The pendulum appliance for Class II non-compliance therapy.","volume":"26","author":"Hilgers","year":"1992","journal-title":"J Clin Orthod"},{"key":"R4-20260602","first-page":"650","article-title":"Maxillary molar distalization with a bone-anchored pendulum appliance.","volume":"76","author":"Kircelli","year":"2006","journal-title":"Angle Orthod"},{"key":"R5-20260602","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1016\/j.ajodo.2006.08.012","article-title":"Distalization of maxillary molars with the bone-supported pendulum: a clinical study.","volume":"131","author":"Escobar","year":"2007","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"R6-20260602","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1016\/j.ajodo.2005.02.034","article-title":"Osseointegrated implants with pendulum springs for maxillary molar distalization: a cephalometric study.","volume":"131","author":"Oncag","year":"2007","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"R7-20260602","doi-asserted-by":"crossref","first-page":"339.e9","DOI":"10.1016\/j.ajodo.2007.10.002","article-title":"Pendulum appliances with 2 anchorage designs: conventional anchorage vs bone anchorage.","volume":"133","author":"Polat-Ozsoy","year":"2008","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"R8-20260602","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1093\/ejo\/cjs059","article-title":"Palatal implant versus zygoma plate anchorage for distalization of maxillary posterior teeth.","volume":"35","author":"Kaya","year":"2013","journal-title":"Eur J Orthod"},{"key":"R9-20260602","doi-asserted-by":"crossref","first-page":"1149","DOI":"10.3758\/BRM.41.4.1149","article-title":"Statistical power analyses using G*Power 3.1: tests for correlation and regression analyses.","volume":"41","author":"Faul","year":"2009","journal-title":"Behav Res Methods"},{"key":"R10-20260602","doi-asserted-by":"crossref","first-page":"c332","DOI":"10.1136\/bmj.c332","article-title":"CONSORT 2010 statement: updated guidelines for reporting parallel group randomized trials.","volume":"340","author":"Schulz","year":"2010","journal-title":"BMJ"},{"key":"R11-20260602","first-page":"261","article-title":"Distal molar movement using the pendulum appliance. Part 2: the effects of maxillary molar root uprighting bends.","volume":"67","author":"Byloff","year":"1997","journal-title":"Angle Orthod"},{"key":"R12-20260602","first-page":"257","article-title":"The effects of premolar-extraction: a long-term comparison of outcomes in extraction and nonextraction Class II patients.","volume":"63","author":"Luppanapornlarp","year":"1993","journal-title":"Angle Orthod"},{"key":"R13-20260602","first-page":"277","article-title":"Molar distalization with superelastic NiTi wire.","volume":"26","author":"Locatelli","year":"1992","journal-title":"J Clin Orthod"},{"key":"R14-20260602","doi-asserted-by":"crossref","first-page":"1133","DOI":"10.2319\/101507-406.1","article-title":"Maxillary molar distalization with noncompliance intramaxillary appliances in Class II malocclusion: a systematic review.","volume":"78","author":"Antonarakis","year":"2008","journal-title":"Angle Orthod"},{"key":"R15-20260602","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1093\/ejo\/14.4.264","article-title":"Distalization of maxillary first and second molars simultaneously with repelling magnets.","volume":"14","author":"Bondemark","year":"1992","journal-title":"Eur J Orthod"},{"key":"R16-20260602","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/S0889-5406(00)70246-0","article-title":"A new approach in maxillary molar distalization: intraoral bodily molar distalizer.","volume":"117","author":"Keles","year":"2000","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"R17-20260602","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1016\/j.ajodo.2003.06.006","article-title":"Dentoskeletal effects induced by rapid molar distalization with the first class appliance.","volume":"125","author":"Fortini","year":"2004","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"R18-20260602","first-page":"471","article-title":"Bodily distalization of molars with absolute anchorage.","volume":"73","author":"Keles","year":"2003","journal-title":"Angle Orthod"},{"key":"R19-20260602","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1016\/S0889-5406(00)70238-1","article-title":"Dentoalveolar and skeletal changes associated with the pendulum appliance.","volume":"117","author":"Bussick","year":"2000","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"R20-20260602","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1053\/od.2000.5901","article-title":"An evaluation of the pendulum distalizing appliance.","volume":"6","author":"Joseph","year":"2000","journal-title":"Semin Orthod"},{"key":"R21-20260602","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1016\/j.ajodo.2007.01.035","article-title":"Comparative distalization effects of Jones jig and pendulum appliances.","volume":"135","author":"Patel","year":"2009","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"R22-20260602","first-page":"539","article-title":"Nonextraction treatment with microscrew implants.","volume":"74","author":"Park","year":"2004","journal-title":"Angle Orthod"},{"key":"R23-20260602","doi-asserted-by":"crossref","first-page":"604.e1","DOI":"10.1016\/j.ajodo.2008.03.013","article-title":"Orthodontic treatment of Class II malocclusion with miniscrew implants.","volume":"134","author":"Papadopoulos","year":"2008","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"R24-20260602","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1016\/S0889-5406(96)80041-2","article-title":"Evaluation of an intraoral maxillary molar distalization technique.","volume":"110","author":"Ghosh","year":"1996","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"R25-20260602","doi-asserted-by":"crossref","first-page":"167","DOI":"10.2319\/102506-438","article-title":"Distal movement of maxillary molars using a lever-arm and mini-implant system.","volume":"78","author":"Lim","year":"2008","journal-title":"Angle Orthod"},{"key":"R26-20260602","doi-asserted-by":"crossref","first-page":"556","DOI":"10.1016\/S0889-5406(05)80439-1","article-title":"Molar and incisor changes with Wilson rapid molar distalization.","volume":"104","author":"Muse","year":"1993","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"R27-20260602","doi-asserted-by":"crossref","first-page":"578","DOI":"10.1016\/j.ajodo.2007.10.049","article-title":"Efficiency of a skeletonized distal jet appliance supported by miniscrew anchorage for noncompliance maxillary molar distalization.","volume":"136","author":"Kinzinger","year":"2009","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"R28-20260602","doi-asserted-by":"crossref","first-page":"194","DOI":"10.2319\/051719-340.1","article-title":"Evaluation of the effects of the hybrid Pendulum in comparison with the conventional Pendulum appliance.","volume":"90","author":"Bozkaya","year":"2020","journal-title":"Angle Orthod"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000044512","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T18:01:42Z","timestamp":1780423302000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000044512"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,26]]},"references-count":27,"journal-issue":{"issue":"39","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000044512","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,26]]},"assertion":[{"value":"2025-05-09","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-08-26","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}