{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,18]],"date-time":"2026-11-18T17:22:49Z","timestamp":1795022569989,"version":"4.10.1"},"reference-count":9,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"43","license":[{"start":{"date-parts":[[2025,10,24]],"date-time":"2025-10-24T00:00:00Z","timestamp":1761264000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,10,24]]},"abstract":"<jats:sec>\n                    <jats:title>Rationale:<\/jats:title>\n                    <jats:p>Continuous invasive blood pressure monitoring is crucial during the perioperative period, particularly in high-risk and critically ill patients. In patients with Takayasu arteritis (TAK) and severe vascular stenosis, conventional arterial cannulation is often technically challenging because of vessel occlusion or fragile tissue. This case report explores the feasibility of using a central venous catheter instead of an arterial puncture kit for invasive blood pressure monitoring when standard arterial catheterization is impractical.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Patient concerns:<\/jats:title>\n                    <jats:p>A 56-year-old female with a history of TAK presented for adrenalectomy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Diagnoses:<\/jats:title>\n                    <jats:p>Medical imaging revealed an adrenal tumor and TAK with multi-territorial vascular involvement (radial, brachial, and dorsalis pedis arteries).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Interventions:<\/jats:title>\n                    <jats:p>The patient underwent adrenal tumor resection. Continuous invasive blood pressure was monitored under ultrasound guidance using an 18-gauge central venous catheter for femoral artery puncture.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Outcomes:<\/jats:title>\n                    <jats:p>The procedure was completed uneventfully with timely hemodynamic monitoring guided by reliable invasive measurements.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Lessons:<\/jats:title>\n                    <jats:p>This alternative method has the potential to reduce the risk of intraoperative catheterization and ensure reliable intraoperative blood pressure monitoring when conventional puncture is impossible.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/md.0000000000045496","type":"journal-article","created":{"date-parts":[[2025,10,24]],"date-time":"2025-10-24T19:01:25Z","timestamp":1761332485000},"page":"e45496","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["An alternative catheter to invasive blood pressure monitoring in a patient with Takayasu arteritis undergoing open adrenalectomy: A case report"],"prefix":"10.1097","volume":"104","author":[{"given":"Xiao","family":"Gu","sequence":"first","affiliation":[{"name":"Department of Anesthesiology, Lianyungang Clinical College of Nanjing Medical University, Lianyungang City, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yunyan","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Lianyungang Clinical College of Nanjing Medical University, Lianyungang City, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhibin","family":"Zhao","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Lianyungang Clinical College of Nanjing Medical University, Lianyungang City, China"},{"name":"Department of Anesthesiology, The First People\u2019s Hospital of Lianyungang, Lianyungang City, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2275-8501","authenticated-orcid":false,"given":"Ying","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Lianyungang Clinical College of Nanjing Medical University, Lianyungang City, China"},{"name":"Department of Anesthesiology, The First People\u2019s Hospital of Lianyungang, Lianyungang City, China."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20261118","doi-asserted-by":"crossref","first-page":"1654","DOI":"10.1136\/ard-2022-223482","article-title":"2022 American College of Rheumatology\/EULAR classification criteria for Takayasu arteritis.","volume":"81","author":"Grayson","year":"2022","journal-title":"Ann Rheum Dis"},{"key":"R2-20261118","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1016\/j.bja.2024.04.046","article-title":"PeriOperative Quality Initiative (POQI) international consensus statement on perioperative arterial pressure management.","volume":"133","author":"Saugel","year":"2024","journal-title":"Br J Anaesth"},{"key":"R3-20261118","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1016\/j.bja.2019.01.013","article-title":"Perioperative Quality Initiative consensus statement on intraoperative blood pressure, risk and outcomes for elective surgery.","volume":"122","author":"Sessler","year":"2019","journal-title":"Br J Anaesth"},{"key":"R4-20261118","doi-asserted-by":"crossref","first-page":"1795","DOI":"10.1007\/s00134-014-3525-z","article-title":"Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine.","volume":"40","author":"Cecconi","year":"2014","journal-title":"Intensive Care Med"},{"key":"R5-20261118","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1186\/s13054-020-02859-w","article-title":"How to measure blood pressure using an arterial catheter: a systematic 5-step approach.","volume":"24","author":"Saugel","year":"2020","journal-title":"Crit Care"},{"key":"R6-20261118","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1007\/s10877-015-9760-1","article-title":"Resonance artefacts in modern pressure monitoring systems.","volume":"30","author":"Bocchi","year":"2016","journal-title":"J Clin Monit Comput"},{"key":"R7-20261118","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1097\/00000542-198103000-00010","article-title":"Direct blood pressure measurement \u2013 dynamic response requirements.","volume":"54","author":"Gardner","year":"1981","journal-title":"Anesthesiology"},{"key":"R8-20261118","doi-asserted-by":"crossref","first-page":"644","DOI":"10.1186\/s13054-014-0644-4","article-title":"Accuracy of invasive arterial pressure monitoring in cardiovascular patients: an observational study.","volume":"18","author":"Romagnoli","year":"2014","journal-title":"Crit Care"},{"key":"R9-20261118","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1007\/s10877-021-00663-7","article-title":"Intraarterial catheter diameter and dynamic response of arterial pressure monitoring system: a randomized controlled trial.","volume":"36","author":"Oh","year":"2022","journal-title":"J Clin Monit Comput"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/MD.0000000000045496","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,18]],"date-time":"2026-11-18T17:02:09Z","timestamp":1795021329000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/MD.0000000000045496"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,24]]},"references-count":9,"journal-issue":{"issue":"43","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000045496","relation":{},"ISSN":["1536-5964","0025-7974"],"issn-type":[{"value":"1536-5964","type":"electronic"},{"value":"0025-7974","type":"print"}],"subject":[],"published":{"date-parts":[[2025,10,24]]},"assertion":[{"value":"2025-06-12","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-09-30","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}