{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:19:11Z","timestamp":1786119551587,"version":"build-2736575974"},"reference-count":34,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2026,1,2]],"date-time":"2026-01-02T00:00:00Z","timestamp":1767312000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,1,2]]},"abstract":"<jats:p>\n                    This study aims to compare the accuracy and reliability of computed tomography (CT) anteversion measurements between the conventional axial plane (CAP) and the functional coronal plane (FCP). We retrospectively examined 68 patients\u2019 postoperative CT scans following primary unilateral total hip arthroplasty (THA). PolyWare software, which uses edge detection to determine radiographic anteversion of the acetabular component, served as the reference standard. We measured anatomical anteversion in the CAP and radiographic anteversion in the reformatted FCP using reconstruction software. Reliability was evaluated with the intraclass correlation coefficient. The mean anteversion of the acetabular component in the CAP and FCP CT images were 29.18\u2005\u00b1\u20056.06\u00b0 and 21.17\u2005\u00b1\u20055.38\u00b0, respectively. The mean CT anteversion in the FCP was considered accurate owing to its similarity with the reference standard (20.70\u2005\u00b1\u20054.39\u00b0,\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    \u2005=\u2005.281). However, the mean CT anteversion in the CAP was significantly different and thus considered less accurate; the CT anteversion in the CAP was larger than that in the FCP, showing a significant linear correlation (\n                    <jats:italic toggle=\"yes\">R<\/jats:italic>\n                    \u2005=\u20050.673,\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    \u2005&lt;\u2005.001), with a difference of 8.01\u00b0. The intraobserver and interobserver reliabilities were excellent for all measurement methods. Using radiographic anteversion defined by digital image analysis software as the reference standard, the anteversion measurement in the reformatted FCP proved more accurate than in the CAP. The reformatted FCP CT image facilitates precise post-THA anteversion measurement, with the method difference being around 8.01\u00b0. This study aids in measuring anteversion via CT.\n                  <\/jats:p>","DOI":"10.1097\/md.0000000000046790","type":"journal-article","created":{"date-parts":[[2026,1,6]],"date-time":"2026-01-06T15:01:04Z","timestamp":1767711664000},"page":"e46790","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Computed tomography analysis of acetabular component anteversion after total hip arthroplasty: A retrospective study comparing conventional axial and functional coronal planes"],"prefix":"10.1097","volume":"105","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7331-9539","authenticated-orcid":false,"given":"Sang-Min","family":"Lee","sequence":"first","affiliation":[{"name":"Department of Orthopedic Surgery, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Republic of Korea"},{"name":"Pusan National University School of Medicine, Pusan National University, Yangsan, Republic of Korea"},{"name":"Department of Molecular Medicine, Shiley Center for Orthopaedic Research and Education at Scripps Clinic, Scripps Research, La Jolla, California"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Min Uk","family":"Do","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Republic of Korea"},{"name":"Pusan National University School of Medicine, Pusan National University, Yangsan, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Suk-Woong","family":"Kang","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Republic of Korea"},{"name":"Pusan National University School of Medicine, Pusan National University, Yangsan, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jung Sub","family":"Lee","sequence":"additional","affiliation":[{"name":"Pusan National University School of Medicine, Pusan National University, Yangsan, Republic of Korea"},{"name":"Department of Orthopedic Surgery, Pusan National University Hospital, Busan, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kuen Tak","family":"Suh","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Republic of Korea"},{"name":"Pusan National University School of Medicine, Pusan National University, Yangsan, Republic of Korea"},{"name":"Department of Orthopedic Surgery, Mirae Hospital, Busan, Republic of Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6918-3015","authenticated-orcid":false,"given":"Won Chul","family":"Shin","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Republic of Korea"},{"name":"Pusan National University School of Medicine, Pusan National University, Yangsan, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20260218","doi-asserted-by":"crossref","first-page":"315","DOI":"10.2106\/00004623-200003000-00003","article-title":"The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios.","volume":"82","author":"D\u2019Lima","year":"2000","journal-title":"J Bone Joint Surg Am"},{"key":"R2-20260218","doi-asserted-by":"crossref","first-page":"217","DOI":"10.2106\/00004623-197860020-00014","article-title":"Dislocations after total hip-replacement arthroplasties.","volume":"60","author":"Lewinnek","year":"1978","journal-title":"J Bone Joint Surg Am"},{"key":"R3-20260218","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1148\/107.3.705","article-title":"Prosthetic hip angulation.","volume":"107","author":"McLaren","year":"1973","journal-title":"Radiology"},{"key":"R4-20260218","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.arth.2007.06.008","article-title":"The influence of acetabular component position on wear in total hip arthroplasty.","volume":"23","author":"Wan","year":"2008","journal-title":"J Arthroplasty"},{"key":"R5-20260218","doi-asserted-by":"crossref","first-page":"1295","DOI":"10.2106\/00004623-198264090-00004","article-title":"Dislocations after total hip arthroplasty.","volume":"64","author":"Woo","year":"1982","journal-title":"J Bone Joint Surg Am"},{"key":"R6-20260218","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1302\/0301-620X.75B2.8444942","article-title":"The definition and measurement of acetabular orientation.","volume":"75","author":"Murray","year":"1993","journal-title":"J Bone Joint Surg Br"},{"key":"R7-20260218","doi-asserted-by":"crossref","first-page":"174","DOI":"10.4055\/cios.2013.5.3.174","article-title":"Ceramic-on-ceramic total hip arthroplasty: minimum of six-year follow-up study.","volume":"5","author":"Choy","year":"2013","journal-title":"Clin Orthop Surg"},{"key":"R8-20260218","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1023\/B:JMSM.0000030214.79180.13","article-title":"Differences between the wear couples metal-on-polyethylene and ceramic-on-ceramic in the stability against dislocation of total hip replacement.","volume":"15","author":"Bader","year":"2004","journal-title":"J Mater Sci Mater Med"},{"key":"R9-20260218","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1302\/0301-620X.92B8.24194","article-title":"Optimal acetabular orientation for hip resurfacing.","volume":"92","author":"Grammatopoulos","year":"2010","journal-title":"J Bone Joint Surg Br"},{"key":"R10-20260218","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1302\/0301-620X.68B3.3733807","article-title":"Anteversion of the acetabular cup. Measurement of angle after total hip replacement.","volume":"68","author":"Ackland","year":"1986","journal-title":"J Bone Joint Surg Br"},{"key":"R11-20260218","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1016\/S0883-5403(05)80187-1","article-title":"Radiographic calculation of anteversion in acetabular prostheses.","volume":"10","author":"Hassan","year":"1995","journal-title":"J Arthroplasty"},{"key":"R12-20260218","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1097\/01.blo.0000223988.41776.fa","article-title":"A new tool for measuring cup orientation in total hip arthroplasties from plain radiographs.","volume":"451","author":"Liaw","year":"2006","journal-title":"Clin Orthop Relat Res"},{"key":"R13-20260218","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1007\/s00402-006-0163-0","article-title":"Misinterpretation of cup anteversion in total hip arthroplasty using planar radiography.","volume":"126","author":"Marx","year":"2006","journal-title":"Arch Orthop Trauma Surg"},{"key":"R14-20260218","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1302\/0301-620X.94B1.27621","article-title":"Reliability and validity of measuring version of the acetabular component.","volume":"94","author":"Nho","year":"2012","journal-title":"J Bone Joint Surg Br"},{"issue":"6)(suppl","key":"R15-20260218","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1016\/j.arth.2011.03.039","article-title":"The reliability and variation of acetabular component anteversion measurements from cross-table lateral radiographs.","volume":"26","author":"Nunley","year":"2011","journal-title":"J Arthroplasty"},{"key":"R16-20260218","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1016\/j.arth.2003.10.016","article-title":"A simplified method to determine acetabular cup anteversion from plain radiographs.","volume":"19","author":"Widmer","year":"2004","journal-title":"J Arthroplasty"},{"key":"R17-20260218","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1016\/j.arth.2009.01.020","article-title":"Minimal radiation dose computed tomography for measurement of cup orientation in total hip arthroplasty.","volume":"25","author":"Arai","year":"2010","journal-title":"J Arthroplasty"},{"key":"R18-20260218","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1097\/00003086-199203000-00027","article-title":"Computed tomography measurement of acetabular cup anteversion and retroversion in total hip arthroplasty.","volume":"276","author":"Mian","year":"1992","journal-title":"Clin Orthop Relat Res"},{"key":"R19-20260218","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1080\/00016470410001169","article-title":"A new CT method for measuring cup orientation after total hip arthroplasty: a study of 10 patients.","volume":"75","author":"Olivecrona","year":"2004","journal-title":"Acta Orthop Scand"},{"key":"R20-20260218","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1302\/0301-620X.96B.33013","article-title":"An analysis of the best method for evaluating anteversion of the acetabular component after total hip replacement on plain radiographs.","volume":"96-B","author":"Nomura","year":"2014","journal-title":"Bone Joint J"},{"key":"R21-20260218","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1007\/s11999-008-0597-5","article-title":"Imaging and navigation measurement of acetabular component position in THA.","volume":"467","author":"Wan","year":"2009","journal-title":"Clin Orthop Relat Res"},{"key":"R22-20260218","doi-asserted-by":"crossref","first-page":"1042","DOI":"10.1302\/0301-620X.101B9.BJJ-2019-0085.R1","article-title":"A precise method for determining acetabular component anteversion after total hip arthroplasty.","volume":"101-B","author":"Murphy","year":"2019","journal-title":"Bone Joint J"},{"key":"R23-20260218","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1302\/0301-620X.97B5.34735","article-title":"The reliability and accuracy of measuring anteversion of the acetabular component on plain anteroposterior and lateral radiographs after total hip arthroplasty.","volume":"97-B","author":"Shin","year":"2015","journal-title":"Bone Joint J"},{"key":"R24-20260218","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1186\/s13018-018-0767-4","article-title":"The best method for evaluating anteversion of the acetabular component after total hip arthroplasty on plain radiographs.","volume":"13","author":"Park","year":"2018","journal-title":"J Orthop Surg Res"},{"key":"R25-20260218","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1016\/j.arth.2006.07.011","article-title":"Difference between 2 measurement methods of version angles of the acetabular component.","volume":"22","author":"Arai","year":"2007","journal-title":"J Arthroplasty"},{"key":"R26-20260218","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1097\/01.blo.0000069891.31220.fd","article-title":"Measurements of pelvic flexion angle using three-dimensional computed tomography.","volume":"411","author":"Nishihara","year":"2003","journal-title":"Clin Orthop Relat Res"},{"key":"R27-20260218","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1080\/00221309.1992.9921158","article-title":"Does memory contaminate test-retest reliability?","volume":"119","author":"McKelvie","year":"1992","journal-title":"J Gen Psychol"},{"key":"R28-20260218","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1037\/0033-2909.86.2.420","article-title":"Intraclass correlations: uses in assessing rater reliability.","volume":"86","author":"Shrout","year":"1979","journal-title":"Psychol Bull"},{"key":"R29-20260218","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1111\/joa.12586","article-title":"Standing sagittal alignment of the whole axial skeleton with reference to the gravity line in humans.","volume":"230","author":"Hasegawa","year":"2017","journal-title":"J Anat"},{"key":"R30-20260218","doi-asserted-by":"crossref","first-page":"357","DOI":"10.2106\/JBJS.F.00628","article-title":"The rationale for tilt-adjusted acetabular cup navigation.","volume":"90","author":"Babisch","year":"2008","journal-title":"J Bone Joint Surg Am"},{"key":"R31-20260218","doi-asserted-by":"crossref","first-page":"812","DOI":"10.1016\/j.arth.2009.04.021","article-title":"A validation model for measurement of acetabular component position.","volume":"25","author":"Malik","year":"2010","journal-title":"J Arthroplasty"},{"key":"R32-20260218","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1097\/01.blo.0000238862.92356.45","article-title":"Functional pelvic orientation measured from lateral standing and sitting radiographs.","volume":"453","author":"DiGioia","year":"2006","journal-title":"Clin Orthop Relat Res"},{"key":"R33-20260218","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1080\/17453670510041501","article-title":"Pelvic tilt makes acetabular cup navigation inaccurate.","volume":"76","author":"Lembeck","year":"2005","journal-title":"Acta Orthop"},{"key":"R34-20260218","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1177\/0363546518825251","article-title":"Long-term outcomes of meniscal allograft transplantation with and without extrusion: mean 12.3-year follow-up study.","volume":"47","author":"Lee","year":"2019","journal-title":"Am J Sports Med"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/MD.0000000000046790","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T18:33:35Z","timestamp":1786041215000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/MD.0000000000046790"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,2]]},"references-count":34,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000046790","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,2]]},"assertion":[{"value":"2025-01-13","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-11-18","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}