{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,6]],"date-time":"2026-05-06T12:22:04Z","timestamp":1778070124264,"version":"3.51.4"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"11","license":[{"start":{"date-parts":[[2026,3,13]],"date-time":"2026-03-13T00:00:00Z","timestamp":1773360000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,3,13]]},"abstract":"<jats:sec>\n                    <jats:title>Rationale:<\/jats:title>\n                    <jats:p>Scapular fractures caused by domestic low-voltage alternating current (220 V, 50 Hz) electrical injury are rare and can be easily missed or misdiagnosed in emergency clinical practice. This report presents 2 such cases and, through a pooled analysis of relevant literature, summarizes and analyzes the underlying mechanism, key points for early diagnosis, and treatment strategies for this rare injury pattern. The aim is to enhance clinical awareness of this condition and to provide a reference for early recognition and standardized management.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Patient concerns:<\/jats:title>\n                    <jats:p>At the instant of electrical current passage through the upper limb, both patients experienced an intense shock, followed immediately by severe shoulder pain and restricted upper limb movement. Upon presentation, despite only minor cutaneous injuries, both patients reported intense pain localized to the scapular region. This discrepancy between the relatively mild superficial findings and the severity of their symptoms caused considerable confusion and concern, with fear of an invisible severe injury.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Diagnoses:<\/jats:title>\n                    <jats:p>Computed tomography imaging confirmed scapular fractures in both patients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Interventions:<\/jats:title>\n                    <jats:p>After excluding the risk of potential systemic injuries, both patients underwent conservative management comprising sling immobilization, analgesia, and progressive rehabilitation exercises.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Outcomes:<\/jats:title>\n                    <jats:p>Following 6 weeks of treatment, both patients reported satisfaction with the therapeutic effect, and at the 6-month follow-up, they demonstrated complete functional recovery of the shoulder joint.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Lessons:<\/jats:title>\n                    <jats:p>Even in the absence of visible entry or exit cutaneous lesions, the intense tetanic muscle contractions induced by low-voltage electrical shock can be sufficient to cause scapular fractures. For patients presenting with shoulder pain following low-voltage alternating current electrical injury \u2013 regardless of skin integrity \u2013 clinicians should maintain a high index of suspicion for this rare injury so as not to miss the diagnosis.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/md.0000000000047431","type":"journal-article","created":{"date-parts":[[2026,3,13]],"date-time":"2026-03-13T20:01:02Z","timestamp":1773432062000},"page":"e47431","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["A case report on 2 cases of closed scapular fractures caused by low-voltage alternating current shock"],"prefix":"10.1097","volume":"105","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5171-7437","authenticated-orcid":false,"given":"Jia-Qi","family":"Jia","sequence":"first","affiliation":[{"name":"Department of Plastic and Burn Surgery, National Key Clinical Construction Specialty, The Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, People\u2019s Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hong-Jun","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Plastic and Burn Surgery, National Key Clinical Construction Specialty, The Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, People\u2019s Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jun-Chao","family":"Dai","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, The Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, People\u2019s Republic of China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-7696-542X","authenticated-orcid":false,"given":"Kang","family":"Geng","sequence":"additional","affiliation":[{"name":"Department of Plastic and Burn Surgery, National Key Clinical Construction Specialty, The Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, People\u2019s Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20260506","doi-asserted-by":"crossref","first-page":"106066","DOI":"10.1016\/j.ijscr.2021.106066","article-title":"A rare case of low voltage electrical injury leading to bilateral femur fractures and vertebral body fractures: a case report and review of the literature.","volume":"84","author":"Ritchie","year":"2021","journal-title":"Int J Surg Case Rep"},{"key":"R2-20260506","doi-asserted-by":"crossref","first-page":"175","DOI":"10.5604\/15093492.1045952","article-title":"Clinical improvement after 2 years one stage bilateral open reduction of chronic anterior shoulder dislocations with internal fixation of greater tuberosity fractures. Case study.","volume":"15","author":"Kubiak","year":"2013","journal-title":"Ortop Traumatol Rehabil"},{"key":"R3-20260506","first-page":"459","article-title":"Comminuted fracture of the scapula following electric shock. A case report.","volume":"57","author":"Simon","year":"1991","journal-title":"Acta Orthop Belg"},{"key":"R4-20260506","first-page":"189","article-title":"Missed posterior fracture-dislocation of the humeral head following an electrocution injury to the arm.","volume":"46","author":"Tan","year":"2005","journal-title":"Singapore Med J"},{"key":"R5-20260506","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1186\/s13256-024-04358-w","article-title":"\u2018Skip\u2019 osteoporosis vertebral compression fractures caused by electrical injury: a case report and review of the literature.","volume":"18","author":"Jia","year":"2024","journal-title":"J Med Case Rep"},{"key":"R6-20260506","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1097\/00005373-197902000-00014","article-title":"Bilateral scapular fractures from accidental electric shock.","volume":"19","author":"Tarquinio","year":"1979","journal-title":"J Trauma"},{"key":"R7-20260506","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1016\/S0196-0644(82)80264-3","article-title":"Bilateral scapular fractures from low-voltage electrical injury.","volume":"11","author":"Beswick","year":"1982","journal-title":"Ann Emerg Med"},{"key":"R8-20260506","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1007\/BF00571527","article-title":"Bilateral scapular fractures secondary to electrical shock.","volume":"111","author":"Dumas","year":"1992","journal-title":"Arch Orthop Trauma Surg"},{"key":"R9-20260506","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1016\/0020-1383(94)90166-X","article-title":"Bilateral simultaneous glenoid fractures.","volume":"25","author":"Dave","year":"1994","journal-title":"Injury"},{"key":"R10-20260506","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1177\/014107680009300310","article-title":"Bilateral scapular fractures after electrocution.","volume":"93","author":"Kotak","year":"2000","journal-title":"J R Soc Med"},{"key":"R11-20260506","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1308\/147870806X95203","article-title":"Scapular fracture after electric shock.","volume":"88","author":"Rana","year":"2006","journal-title":"Ann R Coll Surg Engl"},{"key":"R12-20260506","doi-asserted-by":"crossref","first-page":"1060.e3","DOI":"10.1016\/j.ajem.2010.01.026","article-title":"Posterior comminuted scapular fracture induced by a low-voltage electric shock.","volume":"28","author":"Huang","year":"2010","journal-title":"Am J Emerg Med"},{"key":"R13-20260506","first-page":"1114","article-title":"Operative fixation of an intra-articular scapula fracture from household appliance electrocution: a case report. Article.","volume":"5","author":"Newton","year":"2025","journal-title":"JSES Rev Rep Tech"},{"key":"R14-20260506","doi-asserted-by":"crossref","first-page":"130","DOI":"10.5435\/JAAOS-20-03-130","article-title":"Management of scapular fractures.","volume":"20","author":"Cole","year":"2012","journal-title":"J Am Acad Orthop Surg"},{"key":"R15-20260506","first-page":"8","article-title":"Epidemiology of scapular fractures.","volume":"83","author":"Tu\u010dek","year":"2017","journal-title":"Acta Orthop Belg"},{"key":"R16-20260506","doi-asserted-by":"crossref","first-page":"1018","DOI":"10.1177\/0300985816643371","article-title":"Electrical injuries in animals: causes, pathogenesis, and morphological findings.","volume":"53","author":"Schulze","year":"2016","journal-title":"Vet Pathol"},{"key":"R17-20260506","first-page":"935","article-title":"Long-term sequelae of electrical injury.","volume":"59","author":"Wesner","year":"2013","journal-title":"Can Fam Physician"},{"key":"R18-20260506","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1016\/j.math.2015.09.005","article-title":"Modifying the shoulder joint position during shrugging and retraction exercises alters the activation of the medial scapular muscles.","volume":"21","author":"Castelein","year":"2016","journal-title":"Man Ther"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000047431","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,6]],"date-time":"2026-05-06T12:06:47Z","timestamp":1778069207000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000047431"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,13]]},"references-count":18,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000047431","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,13]]},"assertion":[{"value":"2025-06-23","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-12-02","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}