{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T20:09:14Z","timestamp":1792786154659,"version":"4.5.0"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","license":[{"start":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T00:00:00Z","timestamp":1772755200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"funder":[{"name":"Special Scientific Research Project of Qingdao University Medical Group","award":["YLJT20212002"],"award-info":[{"award-number":["YLJT20212002"]}],"id":[{"id":"https:\/\/ror.org\/021cj6z65","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,3,6]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>The effects of different concentrations of isotonic contrast agents on the quality of hepatic and portal vein imaging and their impact on patients\u2019 renal function remain unclear. This study aimed to assess whether lower concentrations of iodixanol yield high-quality imaging by comparing hepatic and portal vein imaging quality and evaluating renal function following dual-energy CT (DECT) scans.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Patients were randomly assigned to receive either iodixanol at 270 mgI\/mL (iodixanol 270 group, n\u2005=\u200550) or 320 mgI\/mL (iodixanol 320 group, n\u2005=\u200550) and underwent DECT with energy-spectrum reconstruction. Quantitative and qualitative image quality parameters, as well as changes in renal function before and after scanning, were compared between the 2 groups.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Significant differences were observed in the contrast-to-noise ratio, signal-to-noise ratio of the main portal vein, and the computed tomography value of the hepatic vein between the 2 groups (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005&lt;\u2005.05). These parameters were superior in the iodixanol 320 group compared to the iodixanol 270 group. Qualitative evaluation scores for the portal and hepatic veins in the iodixanol 320 group were significantly higher than those in the iodixanol 270 group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005&lt;\u2005.05). Postcontrast acute kidney injury incidence was higher in the iodixanol 320 group than in the iodixanol 270 group (20.5% vs 2.1%,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005&lt;\u2005.05), and this association remained significant after multivariable adjustment (adjusted odds ratio\u2005=\u200513.70,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005=\u2005.002).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>With a fixed injection protocol, iodixanol 320 mgI\/mL yielded higher venous enhancement, whereas iodixanol 270 mgI\/mL provided diagnostically acceptable portal\/hepatic venous image quality on DECT with a lower iodine load. After adjustment, 320 mgI\/mL was associated with higher odds of postcontrast acute kidney injury; this safety signal requires confirmation in larger iodine-matched studies.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/md.0000000000047843","type":"journal-article","created":{"date-parts":[[2026,3,9]],"date-time":"2026-03-09T08:01:52Z","timestamp":1773043312000},"page":"e47843","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Low concentration isotonic iodixanol on hepatic and portal veins imaging quality and renal function: A 320-detector CT dual-energy study"],"prefix":"10.1097","volume":"105","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3423-6092","authenticated-orcid":false,"given":"Jingjing","family":"Wu","sequence":"first","affiliation":[{"name":"Department of Radiology, Hospital of Honghe State affiliated to Kunming Medical University, First People\u2019s Hospital of Honghe Prefecture, Gejiu, Yunnan, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhengyang","family":"Gao","sequence":"additional","affiliation":[{"name":"Department of Radiology, Hospital of Honghe State affiliated to Kunming Medical University, First People\u2019s Hospital of Honghe Prefecture, Gejiu, Yunnan, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guihua","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Radiology, Hospital of Honghe State affiliated to Kunming Medical University, First People\u2019s Hospital of Honghe Prefecture, Gejiu, Yunnan, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lunqing","family":"Pu","sequence":"additional","affiliation":[{"name":"Department of Radiology, Hospital of Honghe State affiliated to Kunming Medical University, First People\u2019s Hospital of Honghe Prefecture, Gejiu, Yunnan, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taisong","family":"Tang","sequence":"additional","affiliation":[{"name":"Department of Radiology, Hospital of Honghe State affiliated to Kunming Medical University, First People\u2019s Hospital of Honghe Prefecture, Gejiu, Yunnan, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mei","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Radiology, Hospital of Honghe State affiliated to Kunming Medical University, First People\u2019s Hospital of Honghe Prefecture, Gejiu, Yunnan, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi","family":"Peng","sequence":"additional","affiliation":[{"name":"Department of Radiology, Hospital of Honghe State affiliated to Kunming Medical University, First People\u2019s Hospital of Honghe Prefecture, Gejiu, Yunnan, China."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20261009","doi-asserted-by":"crossref","first-page":"S20","DOI":"10.1007\/BF02342568","article-title":"The non-ionic isotonic contrast agents. Perspectives and controversies.","volume":"6","author":"Dawson","year":"1996","journal-title":"Eur Radiol"},{"key":"R2-20261009","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1186\/1471-2342-11-12","article-title":"Patient discomfort associated with the use of intra-arterial iodinated contrast media: a meta-analysis of comparative randomized controlled trials.","volume":"11","author":"McCullough","year":"2011","journal-title":"BMC Med Imaging"},{"key":"R4-20261009","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1016\/j.jvs.2011.04.047","article-title":"Contrast-induced nephropathy.","volume":"54","author":"Rundback","year":"2011","journal-title":"J Vasc Surg"},{"key":"R5-20261009","first-page":"809","article-title":"Contrast-induced nephropathy.","volume":"24","author":"Santos","year":"2011","journal-title":"Acta Med Port"},{"key":"R6-20261009","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1016\/j.rce.2018.09.004","article-title":"Radiological iodinated contrast-induced nephropathy.","volume":"219","author":"Mu\u00f1oz de Bustillo Llorente","year":"2019","journal-title":"Rev Clin Esp (Barc)"},{"key":"R7-20261009","doi-asserted-by":"crossref","first-page":"2501","DOI":"10.1016\/j.acra.2023.12.004","article-title":"Low dose iodinated contrast material and radiation for virtual monochromatic imaging in craniocervical dual-layer spectral detector computed tomography angiography: a prospective and randomized study.","volume":"31","author":"Zhou","year":"2024","journal-title":"Acad Radiol"},{"key":"R8-20261009","doi-asserted-by":"crossref","first-page":"6033","DOI":"10.1007\/s00330-023-09575-3","article-title":"Halved contrast medium dose in lower limb dual-energy computed tomography angiography-a randomized controlled trial.","volume":"33","author":"Kristiansen","year":"2023","journal-title":"Eur Radiol"},{"key":"R9-20261009","doi-asserted-by":"crossref","first-page":"4089","DOI":"10.1007\/s00330-023-10403-x","article-title":"Reduction of contrast medium for transcatheter aortic valve replacement planning using a spectral detector CT: a prospective clinical trial.","volume":"34","author":"Langenbach","year":"2024","journal-title":"Eur Radiol"},{"key":"R10-20261009","doi-asserted-by":"crossref","first-page":"798","DOI":"10.1097\/RCT.0000000000000595","article-title":"Comparison of 270 versus 320\u2009mg I\/mL of iodixanol in 1 image assessment of both renal arteries and veins with dual-energy spectral CT imaging in late arterial phase and their influence on renal function.","volume":"41","author":"Zhou","year":"2017","journal-title":"J Comput Assist Tomogr"},{"key":"R11-20261009","doi-asserted-by":"crossref","first-page":"e220306","DOI":"10.1148\/ryct.220306","article-title":"Contrast medium reduction for CTA with photon-counting CT: a new opportunity or more of the same?","volume":"5","author":"Dundas","year":"2023","journal-title":"Radiol Cardiothorac Imag"},{"key":"R12-20261009","doi-asserted-by":"crossref","first-page":"e220140","DOI":"10.1148\/ryct.220140","article-title":"CT angiography of the aorta using photon-counting detector CT with reduced contrast media volume.","volume":"5","author":"Higashigaito","year":"2023","journal-title":"Radiol Cardiothorac Imag"},{"key":"R13-20261009","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1097\/RLI.0000000000000961","article-title":"High-pitch multienergy coronary CT angiography in dual-source photon-counting detector CT scanner at low iodinated contrast dose.","volume":"58","author":"Rajiah","year":"2023","journal-title":"Invest Radiol"},{"key":"R14-20261009","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1148\/radiol.11110648","article-title":"Reduced iodine load at CT pulmonary angiography with dual-energy monochromatic imaging: comparison with standard CT pulmonary angiography \u2013 a prospective randomized trial.","volume":"262","author":"Yuan","year":"2012","journal-title":"Radiology"},{"key":"R15-20261009","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1016\/j.jcct.2014.06.003","article-title":"Reduced iodine load with CT coronary angiography using dual-energy imaging: a prospective randomized trial compared with standard coronary CT angiography.","volume":"8","author":"Raju","year":"2014","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"R16-20261009","first-page":"1984","article-title":"Segmentation of portal vein in multiphase CTA image based on unsupervised domain transfer and pseudo label.","volume":"13","author":"Song","year":"2023","journal-title":"Diagnostics (Basel)"},{"key":"R17-20261009","doi-asserted-by":"crossref","first-page":"110160","DOI":"10.1016\/j.ejrad.2022.110160","article-title":"Comparative study of the image quality of twin beam dual energy and single energy carotid CT angiography.","volume":"148","author":"Wang","year":"2022","journal-title":"Eur J Radiol"},{"key":"R18-20261009","doi-asserted-by":"crossref","first-page":"108666","DOI":"10.1016\/j.ejrad.2019.108666","article-title":"Improved coronary artery contrast enhancement using noise-optimised virtual monoenergetic imaging from dual-source dual-energy computed tomography.","volume":"122","author":"Arendt","year":"2020","journal-title":"Eur J Radiol"},{"key":"R19-20261009","first-page":"949","article-title":"Cardiothoracic CTA in infants referred for aortic arch evaluation: retrospective comparison of iomeprol 350, ioversol 350, iopromide 370 and iodixanol 320.","volume":"8","author":"Pop","year":"2021","journal-title":"Children (Basel)"},{"key":"R20-20261009","doi-asserted-by":"crossref","first-page":"5446","DOI":"10.1111\/jcmm.15196","article-title":"Personalized application of three different concentrations of iodinated contrast media in coronary computed tomography angiography.","volume":"24","author":"Zhang","year":"2020","journal-title":"J Cell Mol Med"},{"key":"R21-20261009","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1097\/RTI.0000000000000633","article-title":"Comparison of coronary computed tomography angiography image quality with high-concentration and low-concentration contrast agents: the randomized CONCENTRATE trial.","volume":"38","author":"Im","year":"2023","journal-title":"J Thorac Imag"},{"key":"R22-20261009","doi-asserted-by":"crossref","first-page":"913","DOI":"10.1007\/s10554-012-0153-y","article-title":"Low contrast- and low radiation dose protocol for cardiac CT of thin adults at 256-row CT: usefulness of low tube voltage scans and the hybrid iterative reconstruction algorithm.","volume":"29","author":"Nakaura","year":"2013","journal-title":"Int J Cardiovasc Imaging"},{"key":"R23-20261009","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1177\/02841851211067144","article-title":"Effect of decreased contrast injection flow rate on aortic enhancement in 80-KV peak CT with contrast dose reduction.","volume":"64","author":"Morisaka","year":"2023","journal-title":"Acta Radiol"},{"key":"R24-20261009","doi-asserted-by":"crossref","first-page":"823","DOI":"10.4103\/0366-6999.202731","article-title":"Contrast dose and radiation dose reduction in abdominal enhanced computerized tomography scans with single-phase dual-energy spectral computerized tomography mode for children with solid tumors.","volume":"130","author":"Yu","year":"2017","journal-title":"Chin Med J (Engl)"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/MD.0000000000047843","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T18:08:03Z","timestamp":1791569283000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/MD.0000000000047843"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,6]]},"references-count":23,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000047843","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,6]]},"assertion":[{"value":"2025-02-17","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-02-06","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}