{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T15:07:46Z","timestamp":1775488066075,"version":"3.50.1"},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"14","license":[{"start":{"date-parts":[[2026,4,3]],"date-time":"2026-04-03T00:00:00Z","timestamp":1775174400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"funder":[{"name":"Medical Science Research Project of Hebei","award":["NO.20250640"],"award-info":[{"award-number":["NO.20250640"]}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,4,3]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Computed tomography angiography (CTA) is a vital preoperative diagnostic tool for chronic limb-threatening ischemia (CLTI). However, its high radiation dose and reliance on iodine contrast agents pose significant challenges, though studies addressing these challenges in CLTI remain limited. This study evaluates the feasibility of using 80-kVp tube voltage with reduced iodine contrast dosage in CTA for CLTI patients, aiming to minimize radiation exposure and contrast volume while preserving diagnostic image quality.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A total of 74 CLTI patients were prospectively enrolled and divided into 2 groups: the experimental group (n\u2005=\u200537) underwent CTA at 80 kVp with a contrast injection rate of 3.5\u2009mL\/s and a total volume of 75 to 85\u2009mL; the control group (n\u2005=\u200537) was scanned at 120 kVp with a contrast injection rate of 4.0\u2009mL\/s and a total volume of 95 to 105\u2009mL. Parameters including radiation dose (volume computed tomography (CT) dose index and dose-length product), iodine intake, and image quality (CT attenuation values, noise, signal-to-noise ratio, contrast-to-noise ratio, and subjective scores) were compared.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The experimental group demonstrated a 19.4% reduction in iodine intake (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005&lt;\u2005.05) and a 30.1% and 29.3% reduction in volume computed tomography dose index and dose-length product, respectively (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005&lt;\u2005.05), compared with the control group. The experimental group demonstrated significantly higher CT attenuation values and increased image noise across all measured levels (all\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005&lt;\u2005.05), while maintaining comparable signal-to-noise ratio across all measured levels (all\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005&gt;\u2005.05). Similarly, contrast-to-noise ratio remained equivalent between groups at the lower abdominal aorta, mid-femoral artery, and mid-popliteal artery levels (all\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005&gt;\u2005.05). The subjective image quality scores showed no significant differences between the experimental and control groups, both above (4.70\u2005\u00b1\u20050.46 vs 4.74\u2005\u00b1\u20050.44,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005=\u2005.43) and below (4.08\u2005\u00b1\u20050.57 vs 4.15\u2005\u00b1\u20050.60,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005=\u2005.15) the popliteal artery level.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Lower-limb CTA using 80-kVp tube voltage and reduced iodine contrast dosage is feasible for CLTI patients, providing diagnostic image quality while significantly reducing radiation exposure and contrast volume. This approach offers a safer and more efficient alternative for preoperative evaluation in this population.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/md.0000000000048193","type":"journal-article","created":{"date-parts":[[2026,4,3]],"date-time":"2026-04-03T16:00:15Z","timestamp":1775232015000},"page":"e48193","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Feasibility of 80-kVp CTA with reduced iodine contrast in chronic limb-threatening ischemia"],"prefix":"10.1097","volume":"105","author":[{"given":"Zequn","family":"Li","sequence":"first","affiliation":[{"name":"Department of Radiology, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yongzhi","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Radiology, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jian","family":"Zhao","sequence":"additional","affiliation":[{"name":"Department of Radiology, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fengkai","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Vascular Interventional Radiology, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Wei","sequence":"additional","affiliation":[{"name":"Department of Radiology, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-5576-4481","authenticated-orcid":false,"given":"Liqiang","family":"Huang","sequence":"additional","affiliation":[{"name":"Department of Radiology, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20260406","doi-asserted-by":"crossref","first-page":"1211","DOI":"10.1016\/S0140-6736(17)32154-2","article-title":"Global, regional, and national incidence and prevalence, and years lived with disability for 328 diseases and injuries in 195 countries, 1990\u20132016: a systematic analysis for the Global Burden of Disease Study 2016.","volume":"390","year":"2017","journal-title":"Lancet"},{"key":"R2-20260406","doi-asserted-by":"crossref","first-page":"6081","DOI":"10.3390\/jcm12186081","article-title":"Limb salvage and survival in chronic limb-threatening ischemia: the need for a fast-track team-based approach.","volume":"12","author":"Ventoruzzo","year":"2023","journal-title":"J Clin Med"},{"key":"R3-20260406","doi-asserted-by":"crossref","first-page":"265","DOI":"10.3348\/kjr.2018.19.2.265","article-title":"Effect of patient characteristics on vessel enhancement at lower extremity CT angiography.","volume":"19","author":"Takanori","year":"2018","journal-title":"Korean J Radiol"},{"key":"R4-20260406","doi-asserted-by":"crossref","first-page":"73","DOI":"10.3400\/avd.ar.23-00096","article-title":"2020 JAPAN critical limb ischemia database (JCLIMB) annual report.","volume":"17","year":"2024","journal-title":"Ann Vasc Dis"},{"key":"R5-20260406","doi-asserted-by":"crossref","first-page":"101082","DOI":"10.1016\/j.cpcardiol.2021.101082","article-title":"Peripheral artery disease: a comprehensive updated review.","volume":"47","author":"Shamaki","year":"2021","journal-title":"Curr Probl Cardiol"},{"key":"R6-20260406","doi-asserted-by":"crossref","first-page":"777016","DOI":"10.3389\/fcvm.2021.777016","article-title":"Statins and peripheral arterial disease: a narrative review.","volume":"8","author":"Jansen-Chaparro","year":"2021","journal-title":"Front Cardiovasc Med"},{"key":"R7-20260406","doi-asserted-by":"crossref","first-page":"496","DOI":"10.2174\/1573405614666181026112532","article-title":"Comparison between computed tomography angiography and digital subtraction angiography in critical lower limb ischemia.","volume":"15","author":"Al-Rudaini","year":"2019","journal-title":"Curr Med Imaging Rev"},{"key":"R8-20260406","doi-asserted-by":"crossref","first-page":"e0139275","DOI":"10.1371\/journal.pone.0139275","article-title":"Dual energy CT angiography of peripheral arterial disease: feasibility of using lower contrast medium volume.","volume":"10","author":"Abdulrahman","year":"2015","journal-title":"PLoS One"},{"key":"R9-20260406","doi-asserted-by":"crossref","first-page":"20220196","DOI":"10.1259\/bjr.20220196","article-title":"Iterative reconstruction vs deep learning image reconstruction: comparison of image quality and diagnostic accuracy of arterial stenosis in low-dose lower extremity CT angiography.","volume":"95","author":"Qu","year":"2022","journal-title":"Br J Radiol"},{"key":"R10-20260406","doi-asserted-by":"crossref","first-page":"896370","DOI":"10.3389\/fsurg.2022.896370","article-title":"Explore the value of dual source computer tomography automatic tube current regulation in reducing the radiation dose of CTA in lower extremity vessels.","volume":"9","author":"Xin","year":"2022","journal-title":"Front Surg"},{"key":"R11-20260406","doi-asserted-by":"crossref","first-page":"1796","DOI":"10.21037\/qims-20-925","article-title":"Feasibility of low-dose contrast media in run-off CT angiography on dual-layer spectral detector CT.","volume":"11","author":"Ren","year":"2021","journal-title":"Quant Imaging Med Surg"},{"key":"R12-20260406","doi-asserted-by":"crossref","first-page":"111817","DOI":"10.1016\/j.ejrad.2024.111817","article-title":"CT imaging using variable helical pitch scanning for lower extremity arterial disease: reduced contrast medium dose, improved image quality and diagnostic accuracy.","volume":"181","author":"Li","year":"2024","journal-title":"Eur J Radiol"},{"key":"R13-20260406","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1016\/j.diii.2018.04.006","article-title":"Lower extremity CT angiography at 80 kVp using iterative model reconstruction.","volume":"99","author":"Liu","year":"2018","journal-title":"Diagn Interv Imaging"},{"key":"R14-20260406","doi-asserted-by":"crossref","first-page":"2758","DOI":"10.1007\/s00330-010-1841-4","article-title":"Comparison of standard- and low-tube voltage MDCT angiography in patients with peripheral arterial disease.","volume":"20","author":"Daisuke","year":"2010","journal-title":"Eur Radiol"},{"key":"R15-20260406","doi-asserted-by":"crossref","first-page":"822","DOI":"10.1177\/0284185115604512","article-title":"Diagnostic performance and radiation dose of lower extremity CT angiography using a 128-slice dual source CT at 80 kVp and high pitch.","volume":"57","author":"Kim","year":"2016","journal-title":"Acta Radiol"},{"key":"R16-20260406","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1097\/RCT.0000000000000365","article-title":"Low-voltage, high-pitch computerized tomography angiography of the infrarenal aorta and lower extremity vessels: assessment of radiation dose, image quality with hybrid iterative reconstruction, and efficacy of test injection using a monitoring scan at knee level.","volume":"40","author":"Zhou","year":"2016","journal-title":"J Comput Assist Tomogr"},{"key":"R17-20260406","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1097\/RCT.0000000000000356","article-title":"Improved image quality and decreased radiation dose of lower extremity computed tomography angiography using low-tube-voltage and adaptive iterative reconstruction.","volume":"40","author":"Pan","year":"2016","journal-title":"J Comput Assist Tomogr"},{"key":"R18-20260406","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.rcl.2015.08.001","article-title":"Computed tomography angiography of the lower extremities.","volume":"54","author":"Cook","year":"2016","journal-title":"Radiol Clin North Am"},{"key":"R19-20260406","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1007\/s11547-018-0963-7","article-title":"Radiation dose and image quality with new protocol in lower extremity computed tomography angiography.","volume":"124","author":"Schicchi","year":"2019","journal-title":"Radiol Med"},{"key":"R20-20260406","doi-asserted-by":"crossref","first-page":"172","DOI":"10.12809\/hkjr1916920","article-title":"Feasibility of reduced radiation dose and iodine load in lower extremity computed tomography angiography.","volume":"22","author":"Park","year":"2019","journal-title":"Hong Kong J Radiol"},{"key":"R21-20260406","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1007\/s11936-015-0375-0","article-title":"Statins in the prevention of contrast-induced nephropathy.","volume":"17","author":"Chyou","year":"2015","journal-title":"Curr Treat Options Cardiovasc Med"},{"key":"R22-20260406","doi-asserted-by":"crossref","first-page":"927","DOI":"10.1177\/1708538120986304","article-title":"The feasibility of low iodine dynamic CT angiography with test bolus for evaluation of lower extremity peripheral artery disease.","volume":"29","author":"Inoue","year":"2021","journal-title":"Vascular"},{"key":"R23-20260406","doi-asserted-by":"crossref","first-page":"1312","DOI":"10.1016\/S0140-6736(17)30057-0","article-title":"Prophylactic hydration to protect renal function from intravascular iodinated contrast material in patients at high risk of contrast-induced nephropathy (AMACING): a prospective, randomised, phase 3, controlled, open-label, non-inferiority trial.","volume":"389","author":"Nijssen","year":"2017","journal-title":"Lancet"},{"key":"R24-20260406","doi-asserted-by":"crossref","first-page":"1751","DOI":"10.1007\/s00270-018-1979-z","article-title":"CT angiography in the lower extremity peripheral artery disease feasibility of an ultra-low volume contrast media protocol.","volume":"41","author":"Horehledova","year":"2018","journal-title":"Cardiovasc Intervent Radiol"},{"key":"R25-20260406","doi-asserted-by":"crossref","first-page":"e169","DOI":"10.5114\/pjr.2020.94297","article-title":"Image quality and radiation exposure with low-contrast-dose computed tomography angiography of the lower extremities.","volume":"85","author":"Assi","year":"2020","journal-title":"Polish J Radiol"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000048193","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T14:00:49Z","timestamp":1775484049000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/MD.0000000000048193"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,3]]},"references-count":25,"journal-issue":{"issue":"14","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000048193","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,3]]},"assertion":[{"value":"2025-12-19","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-03-12","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}