{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,5]],"date-time":"2026-09-05T11:13:05Z","timestamp":1788606785563,"version":"build-2803163510"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"36","license":[{"start":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T00:00:00Z","timestamp":1788480000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Key Research and Development Program of Shaanxi Province","award":["2024SF-YBXM-333"],"award-info":[{"award-number":["2024SF-YBXM-333"]}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,9,4]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>To evaluate the efficacy of a modified soft contact lens (MSCL) in maintaining intraoperative visual clarity and protecting the cornea during vitrectomy using a noncontact wide-angle viewing system.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Patients undergoing pars plana vitrectomy were randomly assigned to a balanced salt solution (BSS) group or an MSCL group. All surgeries were performed with a noncontact wide-angle viewing system. In the BSS group, the cornea was intermittently irrigated with BSS, whereas an MSCL was applied throughout surgery in the MSCL group. Surgical time, vitrectomy duration, intraoperative visual clarity, and frequency of corneal irrigation were recorded. Corneal epithelial edema, fluorescein staining, tear film breakup time, and central corneal thickness were assessed preoperatively and at 1 day, 1 week, and 1 month postoperatively. Ocular Surface Disease Index scores were evaluated preoperatively and at 1 month.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The MSCL group showed significantly better intraoperative visual clarity and corneal hydration than the BSS group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005&lt;\u2005.05). Surgical time and vitrectomy duration were comparable between groups (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005&gt;\u2005.05). Corneal edema, fluorescein staining, and tear film breakup time at 1 day and 1 week were significantly improved in the MSCL group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2005&lt;\u2005.05), with no differences at 1 month. Ocular Surface Disease Index scores did not differ significantly between groups.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>MSCL use effectively protects the cornea and improves intraoperative visualization during vitrectomy without adversely affecting postoperative ocular surface comfort.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/md.0000000000048339","type":"journal-article","created":{"date-parts":[[2026,9,5]],"date-time":"2026-09-05T11:00:48Z","timestamp":1788606048000},"page":"e48339","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Effect of a modified soft contact lens combined with a noncontact wide-angle viewing system during vitrectomy"],"prefix":"10.1097","volume":"105","author":[{"given":"Jintao","family":"Xia","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, First Affiliated Hospital of Northwest University, Xi\u2019an No. 1 Hospital, Xi\u2019an City, Shaanxi Province, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hongbing","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, First Affiliated Hospital of Northwest University, Xi\u2019an No. 1 Hospital, Xi\u2019an City, Shaanxi Province, China"},{"name":"Shaanxi Institute of Ophthalmology, Xi\u2019an City, Shaanxi Province, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lina","family":"Cheng","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, First Affiliated Hospital of Northwest University, Xi\u2019an No. 1 Hospital, Xi\u2019an City, Shaanxi Province, China"},{"name":"Shaanxi Institute of Ophthalmology, Xi\u2019an City, Shaanxi Province, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-3230-0204","authenticated-orcid":false,"given":"Xiaogang","family":"Yang","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, First Affiliated Hospital of Northwest University, Xi\u2019an No. 1 Hospital, Xi\u2019an City, Shaanxi Province, China"},{"name":"Shaanxi Institute of Ophthalmology, Xi\u2019an City, Shaanxi Province, China."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20260905","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1097\/ICU.0000000000000568","article-title":"Small gauge vitrectomy: operative techniques.","volume":"30","author":"Pollack","year":"2019","journal-title":"Curr Opin Ophthalmol"},{"key":"R2-20260905","doi-asserted-by":"crossref","first-page":"6285869","DOI":"10.1155\/2017\/6285869","article-title":"Review of small gauge vitrectomy: progress and innovations.","volume":"2017","author":"Mohamed","year":"2017","journal-title":"J Ophthalmol"},{"key":"R3-20260905","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1159\/000360453","article-title":"Wide-angle viewing system.","volume":"54","author":"Inoue","year":"2014","journal-title":"Dev Ophthalmol"},{"key":"R4-20260905","doi-asserted-by":"crossref","first-page":"360","DOI":"10.3928\/23258160-20130715-07","article-title":"Comparative study of corneal wetting agents during 25-gauge microincision vitrectomy surgery under a noncontact wide-angle viewing system.","volume":"44","author":"Kwon","year":"2013","journal-title":"Ophthalmic Surg Lasers Imaging Retina"},{"key":"R5-20260905","doi-asserted-by":"crossref","first-page":"524","DOI":"10.1097\/APO.0000000000000331","article-title":"Therapeutic contact lenses in the treatment of corneal and ocular surface diseases-a review.","volume":"9","author":"Lim","year":"2020","journal-title":"Asia Pac J Ophthalmol (Phila)"},{"key":"R6-20260905","first-page":"90","article-title":"Corneal endothelial damage and its repair after phacoemulsification.","volume":"40","author":"Xie","year":"2004","journal-title":"Zhonghua Yan Ke Za Zhi"},{"key":"R7-20260905","doi-asserted-by":"crossref","first-page":"1321","DOI":"10.2147\/OPTH.S33595","article-title":"Commercially available rigid gas-permeable contact lens for protecting the cornea from drying during vitrectomy with a wide viewing system.","volume":"6","author":"Kamei","year":"2012","journal-title":"Clin Ophthalmol"},{"key":"R8-20260905","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1097\/ICL.0000000000001087","article-title":"Comparison of Scheimpflug corneal tomography and anterior segment optical coherence tomography measurements in corneal cystinosis: a case series.","volume":"50","author":"Vercauteren","year":"2024","journal-title":"Eye Contact Lens"},{"key":"R9-20260905","doi-asserted-by":"crossref","first-page":"1857","DOI":"10.1007\/s00417-023-06354-0","article-title":"Comparison of central corneal thickness measured by automatic and manual analysis of optical coherence tomography.","volume":"262","author":"Bruttini","year":"2024","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R10-20260905","doi-asserted-by":"crossref","first-page":"3175","DOI":"10.1007\/s10792-023-02717-y","article-title":"Effects of topical prostaglandin therapy on corneal layers thickness in primary open-angle glaucoma patients using anterior segment optical coherence tomography.","volume":"43","author":"Eraslan","year":"2023","journal-title":"Int Ophthalmol"},{"key":"R11-20260905","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1001\/archopht.118.5.615","article-title":"Reliability and validity of the Ocular Surface Disease Index.","volume":"118","author":"Schiffman","year":"2000","journal-title":"Arch Ophthalmol"},{"key":"R12-20260905","doi-asserted-by":"crossref","first-page":"631","DOI":"10.1016\/S0161-6420(99)00176-1","article-title":"Two multicenter, randomized studies of the efficacy and safety of cyclosporine ophthalmic emulsion in moderate to severe dry eye disease. CsA Phase 3 Study Group.","volume":"107","author":"Sall","year":"2000","journal-title":"Ophthalmology"},{"key":"R13-20260905","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1186\/s12886-024-03466-x","article-title":"Clinical features and comprehensive treatment of persistent corneal epithelial dysfunction after cataract surgery.","volume":"24","author":"Xiao","year":"2024","journal-title":"BMC Ophthalmol"},{"key":"R14-20260905","doi-asserted-by":"crossref","first-page":"162","DOI":"10.4103\/ojo.OJO_122_2016","article-title":"Corneal epithelial defect after pars plana vitrectomy.","volume":"10","author":"Al-Hinai","year":"2017","journal-title":"Oman J Ophthalmol"},{"key":"R15-20260905","first-page":"105","article-title":"Factors associated with corneal epithelial defects after pars plana vitrectomy.","volume":"38","author":"Chiang","year":"2018","journal-title":"Int Ophthalmol"},{"key":"R16-20260905","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1097\/IAE.0000000000000657","article-title":"Persistent corneal epithelial defect after pars plana vitrectomy.","volume":"36","author":"Chen","year":"2016","journal-title":"Retina"},{"key":"R17-20260905","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1016\/S0021-5155(01)00376-8","article-title":"Factors contributing to corneal complications after vitrectomy in diabetic patients.","volume":"45","author":"Hiraoka","year":"2001","journal-title":"Jpn J Ophthalmol"},{"key":"R18-20260905","doi-asserted-by":"crossref","first-page":"S355","DOI":"10.1097\/ICL.0000000000000491","article-title":"Thin rigid contact lens used in vitreous-retinal surgery for corneal protection: a randomized controlled trial.","volume":"44","author":"Hu","year":"2018","journal-title":"Eye Contact Lens"},{"key":"R19-20260905","doi-asserted-by":"crossref","first-page":"1135","DOI":"10.4103\/IJO.IJO_17_23","article-title":"Contact lenses for the treatment of ocular surface diseases.","volume":"71","author":"Sharma","year":"2023","journal-title":"Indian J Ophthalmol"},{"key":"R20-20260905","doi-asserted-by":"crossref","first-page":"1142","DOI":"10.4103\/IJO.IJO_2778_22","article-title":"Contact lenses in dry eye disease and associated ocular surface disorders.","volume":"71","author":"Chaudhary","year":"2023","journal-title":"Indian J Ophthalmol"},{"key":"R21-20260905","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1097\/ICL.0000000000001021","article-title":"Performance of bandage contact lens in patients post-ocular surgeries: a systematic literature review.","volume":"49","author":"Zheng","year":"2023","journal-title":"Eye Contact Lens"}],"container-title":["Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/MD.0000000000048339","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,5]],"date-time":"2026-09-05T11:00:52Z","timestamp":1788606052000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/MD.0000000000048339"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,4]]},"references-count":21,"journal-issue":{"issue":"36","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/md.0000000000048339","relation":{},"ISSN":["0025-7974","1536-5964"],"issn-type":[{"value":"0025-7974","type":"print"},{"value":"1536-5964","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,4]]},"assertion":[{"value":"2026-02-11","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-03-27","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}